Home Copper Pipe Refrigeration Copper Pipe 50 ft 1/4 x 1/2 Refrigeration Copper Pipe
50 ft 1/4 x 1/2 Refrigeration Copper Pipe
50 ft 1/4 x 1/2 Refrigeration Copper Pipe
50 ft 1/4 x 1/2 Refrigeration Copper Pipe
50 ft 1/4 x 1/2 Refrigeration Copper Pipe
50 ft 1/4 x 1/2 Refrigeration Copper Pipe
50 ft 1/4 x 1/2 Refrigeration Copper Pipe
50 ft 1/4 x 1/2 Refrigeration Copper Pipe
50 ft 1/4 x 1/2 Refrigeration Copper Pipe
50 ft 1/4 x 1/2 Refrigeration Copper Pipe
50 ft 1/4 x 1/2 Refrigeration Copper Pipe
50 ft 1/4 x 1/2 Refrigeration Copper Pipe
50 ft 1/4 x 1/2 Refrigeration Copper Pipe
1.1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard. 
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m. 
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃. 
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units. 
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410. 
7. Insulation we produce by ourself, can print your company name, size, meters etc.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 50M

Material

99.9% pure copper

Color

Black/White

Keywords

Refrigeration Copper Pipe

Application

HVAC
Inquire
Add to Basket

50 ft 1/4 in. x 1/2 in. Refrigeration Copper Pipe

The DABUND 50 ft 1/4 in. x 1/2 in. Refrigeration Copper Pipe is a pre-insulated twin copper refrigerant line set for compatible air-conditioning, refrigeration, mini split, heat-pump and HVACR installations.

The paired tubing combines a 1/4 in. copper line and a 1/2 in. copper line, equivalent to approximately 6.35 mm and 12.7 mm outside diameter.

It uses 99.9% pure copper with Black Rubber / high-density closed-cell insulation for thermal coverage, moisture resistance and condensation control.

Quick Answer: The 1/4 x 1/2 line-set family is commonly used with compatible 1.5–2.0 ton / 12,000–18,000 BTU mini split systems. Final tube size, refrigerant-line function, permitted piping length and refrigerant charge must follow the HVAC equipment manufacturer's installation manual.

Refrigeration Copper Pipe for HVACR Applications

This 50 ft refrigeration copper pipe is designed as a pre-insulated HVACR refrigerant line set for connecting compatible indoor and outdoor equipment.

Factory-applied insulation helps reduce unwanted heat transfer and surface condensation while providing protection around the copper tubing during transportation and installation.

The continuous 50 ft coil can also reduce the number of field joints required compared with combining multiple shorter copper sections.

Key Features

  • 50 ft twin refrigeration copper pipe coil

  • 1/4 in. x 1/2 in. outside diameter copper tubing

  • Metric size: 6.35 mm x 12.7 mm

  • 99.9% pure copper

  • ASTM B280 and C12200 DHP copper specification

  • Black Rubber / high-density closed-cell insulation

  • Working temperature range from -40°C to 120°C

  • UV-resistant insulation options available

  • Multiple flame-resistant insulation options available

  • Suitable for compatible mini split, heat-pump, centralized ducted and refrigeration applications

  • Custom company name, size and length printing available

  • OEM and private-label packaging available

1/4 in. and 1/2 in. Copper Refrigerant Lines

1/4 in. Copper Line

The 1/4 in. copper tube is commonly used as the liquid refrigerant line in compatible HVAC systems.

1/2 in. Copper Line

The 1/2 in. copper tube is commonly used as the suction refrigerant line in compatible mini split and HVAC systems.

Always confirm both required tube diameters and their refrigerant-line functions from the exact HVAC equipment piping diagram before ordering.

Typical AC Capacity for 1/4 x 1/2 Line Sets

The 1/4 in. + 1/2 in. line-set family is commonly used with some 1.5–2.0 ton mini split air-conditioning systems.

A typical capacity range is approximately 12,000–18,000 BTU.

HVAC capacity alone should not be used to select refrigerant tubing. The equipment manufacturer's specified liquid-line and suction-line sizes always take priority.

99.9% Pure Copper for HVACR Refrigerant Piping

The tubing uses 99.9% pure copper for compatible air-conditioning and refrigeration applications.

ASTM B280 and C12200 DHP

The copper tubing is specified to ASTM B280 using C12200 DHP copper for compatible HVACR refrigerant piping.

99.9 percent pure copper pipe for refrigeration copper pipe

99.9% Pure Copper

Black Rubber insulated refrigeration copper pipe

Black Rubber Insulated Pipe

plastic cap protection for AC copper pipe line set

Plastic Cap Protection

Black Rubber Closed-Cell Insulation

Black Rubber insulation provides thermal coverage, moisture resistance and condensation control around the refrigeration copper tubing.

Working Temperature Range

Applicable insulation configurations are specified for working temperatures from approximately -40°C to 120°C.

Moisture and Condensation Control

The closed-cell structure helps limit moisture penetration and reduce surface condensation around cold refrigerant tubing.

UV-Resistant Options

UV-resistant insulation configurations are available for compatible indoor-to-outdoor HVACR refrigerant piping applications.

Black Rubber pipe insulation for refrigeration copper pipe

Insulation Test Options

Applicable Black Rubber or other matching insulation configurations are available with fire, smoke, UV and material-performance test options.

  • ASTM E84 25/50 fire and smoke performance options

  • UL94 options

  • UL723 surface-burning options

  • ASTM D1056 options

  • ASTM G21 options

  • UV-resistant insulation options

Confirm the matching test report for the exact insulation material and thickness required for the order.

Copper Pressure Range

Available copper configurations are specified within a 2100–7000 PSI range.

Actual allowable working pressure depends on tube diameter, copper wall thickness, operating temperature and the exact ordered specification.

Always confirm the applicable copper tubing specification against the HVAC or refrigeration equipment requirements before installation.

HVAC and Refrigeration Applications

  • Ductless mini split air conditioners

  • Ductless AC systems

  • Heat-pump systems

  • Centralized air ducted units

  • Residential HVAC installations

  • Light commercial HVAC projects

  • Compatible refrigeration equipment

  • Replacement refrigerant-line projects

  • HVACR retrofit installations

Product Specifications

ItemSpecification
Product Name50 ft 1/4 in. x 1/2 in. Refrigeration Copper Pipe
Line Size1/4 in. x 1/2 in.
Metric Size6.35 mm x 12.7 mm
Length50 ft per roll
Copper Material99.9% pure copper
Copper StandardASTM B280 and C12200 DHP
Insulation MaterialBlack Rubber / high-density closed-cell insulation
Temperature Range-40°C to 120°C
Pressure Rating2100 PSI to 7000 PSI
ApplicationAir conditioning, refrigeration, mini split, heat pump and centralized ducted units

Pressure Note: The 2100–7000 PSI range applies across available copper configurations. Actual allowable working pressure depends on tube diameter, wall thickness, temperature and exact specification.

Refrigeration Copper Pipe Size Options

SizeLengthInsulation Black RubberFlame Resistant
1/4 + 3/815m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
1/4 + 1/215m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
1/4 + 5/815m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
3/8 + 5/815m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
3/8 + 3/415m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
1/2 + 3/415m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
3/8 + 7/815m / 20m / 25m / 30m / 50m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1

Length Note: This SKU is supplied as a 50 ft coil. The table above shows additional metric lengths available across the wider refrigeration copper pipe range.

Recommended Applications by AC Capacity

Line Set SizeCommon AC CapacityTypical BTU RangeTypical Application
1/4 + 3/80.75 ton - 1.0 ton9,000 BTU - 12,000 BTUSmall mini split air conditioner
1/4 + 1/21.5 ton - 2.0 ton12,000 BTU - 18,000 BTUResidential mini split system
1/4 + 5/82.0 ton - 2.5 ton24,000 BTU - 30,000 BTUSplit air conditioner system
3/8 + 5/83.0 ton - 4.0 ton36,000 BTU - 48,000 BTUDuctless mini split and heat pump
3/8 + 3/44.5 ton - 6.0 ton54,000 BTU - 72,000 BTULarger split AC installation
3/8 + 7/86.0 ton - 8.0 ton72,000 BTU - 96,000 BTUCommercial ductless HVAC systems

These capacity values provide general product-family guidance. Final refrigerant-line selection must follow the HVAC equipment manufacturer's exact piping requirements.

Important Checks for a 50 ft Refrigerant Run

Confirm the Required 1/4 x 1/2 Tube Sizes

Verify that the HVAC or refrigeration equipment specifically requires 1/4 in. and 1/2 in. copper tubing.

Confirm the Function of Each Tube

Confirm the liquid, suction or other refrigerant-line function of each tube from the equipment manufacturer's piping diagram.

Verify Maximum Piping Length

A physical 50 ft coil does not mean every HVAC system permits a 50 ft refrigerant run. Confirm the equipment manufacturer's maximum piping length.

Check Minimum Piping Length

Some HVAC equipment specifies a minimum piping length. Confirm both minimum and maximum limits where applicable.

Check Maximum Elevation Difference

Verify the permitted vertical separation between indoor and outdoor equipment.

Check Refrigerant Charge Requirements

Confirm whether the equipment's factory refrigerant charge covers the actual installed piping length or whether additional refrigerant is required.

Check Equivalent Piping Length

Bends, fittings and elevation changes can increase equivalent piping length. Follow the equipment manufacturer's equivalent-length limits where applicable.

OEM and Private-Label Refrigeration Copper Pipe

  • Copper sizes from 1/4 in. to 1 1/8 in.

  • Multiple paired copper-line combinations

  • 15 m / 20 m / 25 m / 30 m / 50 m family lengths

  • Multiple insulation thickness options

  • Black Rubber and other applicable insulation configurations

  • Company-name printing

  • Pipe-size and length markings

  • OEM branding

  • Private-label packaging

Black Rubber copper line set for 50 ft 1/4 x 1/2 refrigeration copper pipe

DABUND Factory

DABUND manufactures refrigeration copper pipe, mini split line sets, insulated copper tubing, aluminum pipes and related HVAC products for HVACR wholesalers, contractors, distributors and private-label customers.

DABUND factory copper line set package for refrigeration copper pipe

Insulation Test Documentation

Applicable Polypropylene or Black Rubber insulation configurations can be supplied with UV-resistant options and test documentation referencing ASTM E84, UL94, ASTM D1056 and ASTM G21.

For projects requiring specific compliance documentation, confirm the matching report for the exact insulation material and thickness ordered.

SGS certificate for refrigeration copper pipe insulation

International HVAC Exhibitions

DABUND participates in international HVAC exhibitions where buyers can review refrigeration copper pipe, mini split line sets and related HVACR products.

DABUND HVAC exhibition for refrigeration copper pipe

Frequently Asked Questions

What is 50 ft 1/4 x 1/2 refrigeration copper pipe used for?

It is used as paired refrigerant tubing for compatible mini split air conditioners, heat pumps, ductless AC systems, centralized ducted units and refrigeration equipment.

What does 1/4 x 1/2 mean?

It refers to the outside diameters of the two copper refrigerant tubes. The sizes are approximately 6.35 mm and 12.7 mm.

What AC capacity commonly uses a 1/4 x 1/2 line set?

The 1/4 x 1/2 line-set family is commonly used with some 1.5–2.0 ton or 12,000–18,000 BTU mini split systems. Always confirm the equipment manufacturer's required tube sizes.

Does the copper tubing meet ASTM B280?

Yes. The copper tubing is specified to ASTM B280 using C12200 DHP copper for compatible HVAC and refrigeration applications.

What insulation material is used?

This product uses Black Rubber / high-density closed-cell insulation for thermal coverage, moisture resistance and condensation control.

What is the insulation temperature range?

Applicable insulation configurations are specified for working temperatures from approximately -40°C to 120°C.

What does the 2100–7000 PSI range mean?

It is the specified range across available copper configurations. Actual allowable working pressure depends on tube diameter, wall thickness, temperature and the exact ordered specification.

Can this refrigeration copper pipe be used with R410A?

It can be used in compatible R410A applications when the equipment requires the selected tube sizes and the copper specification and allowable pressure match the system requirements.

Is 50 ft suitable for every 12K–18K mini split?

No. Confirm the HVAC equipment manufacturer's minimum and maximum piping lengths, elevation limits and refrigerant-charge requirements.

Does a 50 ft refrigerant run require additional refrigerant?

It may. Additional refrigerant depends on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions.

Can DABUND print my company name on the insulation?

Yes. DABUND can provide company-name printing, pipe-size markings, length markings and other custom branding for OEM and private-label orders.

Can DABUND provide other sizes and lengths?

Yes. Copper sizes include 1/4 in., 3/8 in., 1/2 in., 5/8 in., 3/4 in., 7/8 in. and 1 1/8 in., with multiple metric coil lengths available.

Is DABUND a manufacturer?

DABUND manufactures refrigeration copper pipe, mini split line sets, insulated copper tubing, aluminum pipes and related HVAC products.

Are free samples available?

Up to 3 free samples are available for qualified customers. Express shipping costs may need to be covered by the buyer.

What payment terms are available?

Payment terms include T/T, L/C at sight, credit card and other agreed payment methods depending on order details.

What delivery terms are available?

DABUND can offer EXW, FOB, CFR and CIF for international orders.

What is the typical delivery time?

Normal delivery time is usually 15–20 days, subject to order requirements and factory scheduling.

Related Products

Please select a data source

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.