1.Insulated Copper Pipe including one set air conditioner insulated copper tube, size 1/4"+5/8" 50 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts. 
2. Both of the two copper pipe end do flaring and nuts. 
3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm. 
4. For the Insulated Copper Pipe, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m. 
5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200. 
6.Professional manufacturer of Insulated Copper Tube, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 10M

Material

99.9% pure copper

Color

Black/White

Keywords

Insulated Copper Tube

Application

HVAC
Inquire
Add to Basket

50 Ft 1/4" x 5/8" Insulated Copper Tube

DABUND 50 Ft 1/4" x 5/8" Insulated Copper Tube is a pre-insulated copper line set for compatible HVACR and split air-conditioning systems requiring 1/4-inch and 5/8-inch refrigerant tubing.

This configuration is supplied with 1/2" Black Rubber insulation according to the current product information. Both copper tubes have factory-prepared flared ends and nuts for compatible flare-type HVAC connections.

The copper tubing is identified with ASTM B280 and C12200 DHP references. The 50 ft configuration is intended for installations where the HVAC equipment manufacturer permits this piping length and the 1/4" x 5/8" tubing combination.

Quick Answer: This product is a 50 ft 1/4" x 5/8" pre-insulated copper line set with 1/2" Black Rubber insulation, flared copper tube ends and nuts for compatible HVACR installations.

Compatibility Notice: The current DABUND product information associates 1/4" x 5/8" tubing with some approximately 2–2.5 ton or 24,000–30,000 BTU split air-conditioning systems. This is only a general selection reference. Always confirm the required liquid and suction line sizes in the actual HVAC equipment installation manual.

Long-Line Notice: For a 50 ft refrigerant piping route, confirm the equipment manufacturer's maximum permitted line length, vertical separation, factory refrigerant charge and any additional refrigerant or long-line installation requirements before installation.

50 Ft 1/4" x 5/8" Copper Line Set Specifications

Product TypePre-Insulated Copper Tube / Copper Line Set
Tube Size1/4" x 5/8"
Length50 ft
Insulation1/2" Black Rubber
Copper Tube ReferenceASTM B280 / C12200 DHP
Tube End PreparationFlared ends with nuts
Black Rubber Temperature Range-40°C to 120°C according to current product information
General Capacity ReferenceSome 24K–30K BTU / approximately 2–2.5 ton systems; equipment specifications govern actual sizing
Typical ApplicationCompatible HVACR and split AC systems requiring 1/4" x 5/8" refrigerant tubing

50 Ft Pre-Insulated Copper Line Set

The 50 ft line set combines 1/4" and 5/8" copper tubing with factory-applied Black Rubber insulation for compatible HVAC installations requiring a longer refrigerant piping route.

Pre-insulated construction reduces the need to separately apply insulation around the refrigerant tubing at the installation site and provides a consistent insulated piping configuration.

Because the selected line length is 50 ft, the piping route should be checked carefully against the equipment manufacturer's permitted refrigerant-line length before installation.

ASTM B280 and C12200 Copper Tubing

DABUND identifies the copper tubing in this product range with ASTM B280 and C12200 DHP references for HVACR copper tube applications.

The current product information also describes the tubing as all-copper construction and identifies the copper as 99.9% pure.

Required wall thickness, allowable operating conditions and piping requirements should still be confirmed for the exact HVAC equipment and project specification.

Factory-Prepared Flared Ends with Nuts

Both copper tube ends are supplied with factory-prepared flares and nuts according to the current product information.

Before installation, inspect the flare surfaces and verify that the flare dimensions, nuts and connection method are compatible with the HVAC equipment service valves.

Copper tubing for 50 ft 1/4 x 5/8 insulated copper line set

Copper Tube

Black Rubber insulated 1/4 x 5/8 HVAC copper tubing

Black Rubber Insulated Pipe

Factory-prepared flared copper tube ends for HVAC line set installation

Flared Ends

1/2" Black Rubber Insulation

This 50 ft 1/4" x 5/8" configuration is identified with 1/2" Black Rubber insulation in the current product information.

The Black Rubber layer provides thermal insulation and moisture control around the refrigerant tubing and helps limit condensation on the insulated line.

The current Black Rubber product information lists a temperature range from -40°C to 120°C.

Different insulation configurations are available across the wider product range. Confirm the required insulation type and thickness for the exact ordered product.

Black Rubber insulation around pre-insulated HVAC copper tubing

Black Rubber Insulation Features

Thermal Insulation

The insulation layer helps reduce heat transfer between the refrigerant tubing and the surrounding environment.

Moisture and Condensation Control

The current product information describes the Black Rubber material as functioning as both an insulation layer and a moisture-control layer.

Temperature Range

The listed Black Rubber insulation temperature range is -40°C to 120°C.

Test References

The current product information references ASTM E84, UL94, ASTM D1056 and ASTM G21 for insulation-related testing. Buyers requiring a specific test report or classification should confirm which documentation applies to the exact Black Rubber insulation configuration being ordered.

Installation Accessories

The current product information references an insulated copper line-set package that can include communication wire cable, a 3 m drain hose, wall pipe, wall cover and other installation parts.

Exact package contents should be confirmed specifically for the 50 ft 1/4" x 5/8" SKU before ordering, especially for distributor, contractor and project purchases.

Black Rubber insulated 1/4 x 5/8 copper line set with HVAC installation accessories

Available Insulated Copper Line Set Sizes

DABUND supplies multiple copper tube combinations, insulation thicknesses and line-set lengths for different HVAC installation requirements.

Copper Tube SizeAvailable LengthsBlack Rubber Insulation OptionsListed Flame Class
1/4" + 3/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4" + 1/2"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4" + 5/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8" + 5/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8" + 3/4"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/2" + 3/4"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8" + 7/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1

Note: The table above represents the wider DABUND insulated copper tubing range. This page specifically covers the 50 ft 1/4" x 5/8" configuration with 1/2" Black Rubber insulation.

1/4" x 5/8" Line Set for Compatible 24K–30K Systems

The current DABUND product information associates the 1/4" x 5/8" tubing combination with some approximately 2–2.5 ton or 24,000–30,000 BTU split air-conditioning systems.

This is a general product-family reference rather than a universal equipment compatibility rule.

Different HVAC models with the same nominal capacity can require different liquid and suction line sizes. Always verify the required refrigerant piping dimensions in the equipment manufacturer's installation manual.

Important Checks for a 50 Ft Refrigerant Line

Maximum Permitted Piping Length

Confirm that a 50 ft refrigerant piping route is within the maximum line length permitted by the specific HVAC equipment manufacturer.

Minimum Permitted Piping Length

Some HVAC systems also specify a minimum refrigerant-line length. Follow the manufacturer's requirements if the actual equipment-to-equipment route is substantially shorter.

Vertical Separation

If the indoor and outdoor units are installed at different elevations, confirm the maximum permitted vertical separation in the equipment installation documentation.

Piping Route and Bends

For longer or more complex routing with multiple bends, follow the equipment manufacturer's piping-layout requirements and permitted line-length criteria.

Additional Refrigerant

Check the equipment factory refrigerant charge and the piping length included in that charge. Some HVAC systems require additional refrigerant when the installed line exceeds the manufacturer's standard allowance.

Long-Line Installation Requirements

If the HVAC equipment manufacturer publishes specific long-line installation requirements, follow those instructions for the actual system.

How to Install a 50 Ft 1/4" x 5/8" Copper Line Set

Step 1: Confirm Equipment Compatibility

Check the HVAC equipment model and confirm that 1/4" x 5/8" is the required refrigerant-line size.

Step 2: Plan the 50 Ft Piping Route

Plan the route between the indoor and outdoor units and verify that the selected line length complies with the equipment manufacturer's piping limits.

Step 3: Inspect the Copper Tubing and Insulation

Inspect the tubing and Black Rubber insulation before installation and avoid crushing, sharp bends or insulation damage during routing.

Step 4: Inspect the Flared Ends

Check the factory-prepared flare surfaces and nuts before connecting them to compatible equipment service valves.

Step 5: Make the Refrigerant Connections

Follow the HVAC equipment manufacturer's flare-joint connection and tightening requirements.

Step 6: Leak Test and Evacuate

Complete the required leak testing and evacuation procedures according to the equipment manufacturer's installation instructions before system operation.

Step 7: Confirm Refrigerant Charge

Confirm whether the installed 50 ft piping length requires additional refrigerant according to the actual equipment manufacturer's instructions.

HVACR Applications

The 50 ft 1/4" x 5/8" insulated copper line set can be considered for compatible HVACR equipment that specifically requires this tubing combination and permits the selected piping length.

  • Compatible split air-conditioning systems

  • Compatible ductless mini split systems

  • Compatible heat-pump installations

  • HVAC equipment requiring 1/4" x 5/8" refrigerant tubing

  • Some compatible 24K–30K BTU applications

  • Projects requiring longer indoor-to-outdoor refrigerant piping routes

Compatibility must always be verified using the exact HVAC equipment model and installation documentation.

Information to Confirm Before Ordering

HVAC distributors, wholesalers, contractors and professional buyers should confirm the following information before placing an order:

  • Required copper tube size: 1/4" x 5/8"

  • Required line-set length: 50 ft

  • HVAC equipment model

  • Maximum permitted piping length

  • Vertical separation requirements

  • Refrigerant charge requirements

  • Required insulation type and thickness

  • Required package accessories

  • Order quantity

  • Packaging requirements

  • OEM or private-label requirements

DABUND Insulated Copper Tube Manufacturer

DABUND has produced insulated copper pipe, mini split line sets and related HVAC installation products since 2008.

Multiple copper tube size combinations, insulation configurations and line-set lengths are available for HVAC distributors, wholesalers, contractors and professional buyers.

OEM and ODM requirements can be discussed according to tubing size, insulation configuration, packaging and commercial order requirements.

DABUND Factory

DABUND produces insulated copper pipe, mini split line sets, aluminum pipe and related HVAC installation products.

DABUND factory production and packaging of insulated copper line sets

Insulation Test References

The current product information references ASTM E84, UL94, ASTM D1056 and ASTM G21 for insulation-related testing.

Because different insulation materials and configurations are available, buyers requiring a particular report or classification should confirm that the requested documentation applies to the exact Black Rubber insulation configuration being ordered.

Test certificate for DABUND insulated copper tubing and insulation

Exhibition

DABUND presents insulated copper line sets and related HVAC installation products at industry exhibitions for international customers and professional buyers.

DABUND insulated copper line sets displayed at an HVAC industry exhibition

Frequently Asked Questions

What size is this insulated copper line set?

This product uses 1/4" and 5/8" copper tubing.

How long is this copper line set?

This product is supplied in a 50 ft length.

What insulation is used on this 50 ft line set?

The current product information identifies this configuration with 1/2" Black Rubber insulation.

What copper standards are listed?

The current product information identifies ASTM B280 and C12200 DHP references for the copper tubing.

Are the copper tube ends flared?

Yes. Both copper tube ends are described as flared and supplied with nuts.

What is the listed temperature range for the Black Rubber insulation?

The current product information lists a Black Rubber insulation temperature range from -40°C to 120°C.

What system capacity commonly uses 1/4" x 5/8" tubing?

The current DABUND product information associates 1/4" x 5/8" tubing with some approximately 2–2.5 ton or 24,000–30,000 BTU split air-conditioning systems. This is only a general reference.

Can this line set be used with every 24,000 or 30,000 BTU air conditioner?

No. Different equipment models can require different refrigerant line sizes even when nominal capacities are similar. Confirm the required tubing sizes in the equipment installation manual.

Is a 50 ft line set suitable for every HVAC installation?

No. Confirm that 50 ft falls within the minimum and maximum refrigerant piping lengths permitted by the actual HVAC equipment manufacturer.

Does a 50 ft line require additional refrigerant?

It depends on the HVAC equipment. Check the factory refrigerant charge, included piping-length allowance and any refrigerant adjustment instructions provided by the manufacturer.

Does vertical separation matter with a 50 ft line set?

Yes. Confirm the permitted elevation difference between the indoor and outdoor units in the equipment manufacturer's installation documentation.

Do I need to follow long-line installation instructions?

If the HVAC equipment manufacturer publishes specific requirements for longer refrigerant piping, follow those instructions for the actual installation.

Can this copper line set be used with a heat pump?

It can be considered for compatible heat-pump equipment that specifically requires 1/4" x 5/8" refrigerant tubing and permits the selected line length.

Can this line set be used with VRF equipment?

Only where the applicable VRF system design specifically requires this tubing combination and permits the selected piping configuration.

What accessories can be supplied with this line set?

The current product information references communication wire cable, a 3 m drain hose, wall pipe, wall cover and other installation parts. Confirm the exact package contents for this 50 ft 1/4" x 5/8" SKU before ordering.

Are other copper tube sizes available?

Yes. The current product range includes 1/4" x 3/8", 1/4" x 1/2", 1/4" x 5/8", 3/8" x 5/8", 3/8" x 3/4", 1/2" x 3/4" and 3/8" x 7/8" combinations.

Can DABUND provide OEM or ODM insulated copper line sets?

Yes. OEM and ODM requirements can be discussed according to tubing size, insulation configuration, packaging and commercial order requirements.

Can I request a sample?

Sample requests are available according to the current sales policy. View sample information.

What payment terms are available?

Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.

What delivery terms are available?

Available international trade terms can include EXW, FOB, CFR and CIF.

What is the typical delivery time?

The current product information lists a typical delivery period of approximately 15–20 days. Actual lead time depends on order quantity, product configuration, customization and production schedule.

Related Products

1. 3/8" x 7/8" x 50 ft is the out dimension in inch. 9.52mm - 22.22mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.