50 Ft 1/4" x 5/8" Insulated Copper Tube
DABUND 50 Ft 1/4" x 5/8" Insulated Copper Tube is a pre-insulated copper line set for compatible HVACR and split air-conditioning systems requiring 1/4-inch and 5/8-inch refrigerant tubing.
This configuration is supplied with 1/2" Black Rubber insulation according to the current product information. Both copper tubes have factory-prepared flared ends and nuts for compatible flare-type HVAC connections.
The copper tubing is identified with ASTM B280 and C12200 DHP references. The 50 ft configuration is intended for installations where the HVAC equipment manufacturer permits this piping length and the 1/4" x 5/8" tubing combination.
Quick Answer: This product is a 50 ft 1/4" x 5/8" pre-insulated copper line set with 1/2" Black Rubber insulation, flared copper tube ends and nuts for compatible HVACR installations.
Compatibility Notice: The current DABUND product information associates 1/4" x 5/8" tubing with some approximately 2–2.5 ton or 24,000–30,000 BTU split air-conditioning systems. This is only a general selection reference. Always confirm the required liquid and suction line sizes in the actual HVAC equipment installation manual.
Long-Line Notice: For a 50 ft refrigerant piping route, confirm the equipment manufacturer's maximum permitted line length, vertical separation, factory refrigerant charge and any additional refrigerant or long-line installation requirements before installation.
50 Ft 1/4" x 5/8" Copper Line Set Specifications
| Product Type | Pre-Insulated Copper Tube / Copper Line Set |
| Tube Size | 1/4" x 5/8" |
| Length | 50 ft |
| Insulation | 1/2" Black Rubber |
| Copper Tube Reference | ASTM B280 / C12200 DHP |
| Tube End Preparation | Flared ends with nuts |
| Black Rubber Temperature Range | -40°C to 120°C according to current product information |
| General Capacity Reference | Some 24K–30K BTU / approximately 2–2.5 ton systems; equipment specifications govern actual sizing |
| Typical Application | Compatible HVACR and split AC systems requiring 1/4" x 5/8" refrigerant tubing |
50 Ft Pre-Insulated Copper Line Set
The 50 ft line set combines 1/4" and 5/8" copper tubing with factory-applied Black Rubber insulation for compatible HVAC installations requiring a longer refrigerant piping route.
Pre-insulated construction reduces the need to separately apply insulation around the refrigerant tubing at the installation site and provides a consistent insulated piping configuration.
Because the selected line length is 50 ft, the piping route should be checked carefully against the equipment manufacturer's permitted refrigerant-line length before installation.
ASTM B280 and C12200 Copper Tubing
DABUND identifies the copper tubing in this product range with ASTM B280 and C12200 DHP references for HVACR copper tube applications.
The current product information also describes the tubing as all-copper construction and identifies the copper as 99.9% pure.
Required wall thickness, allowable operating conditions and piping requirements should still be confirmed for the exact HVAC equipment and project specification.
Factory-Prepared Flared Ends with Nuts
Both copper tube ends are supplied with factory-prepared flares and nuts according to the current product information.
Before installation, inspect the flare surfaces and verify that the flare dimensions, nuts and connection method are compatible with the HVAC equipment service valves.

Copper Tube

Black Rubber Insulated Pipe

Flared Ends
1/2" Black Rubber Insulation
This 50 ft 1/4" x 5/8" configuration is identified with 1/2" Black Rubber insulation in the current product information.
The Black Rubber layer provides thermal insulation and moisture control around the refrigerant tubing and helps limit condensation on the insulated line.
The current Black Rubber product information lists a temperature range from -40°C to 120°C.
Different insulation configurations are available across the wider product range. Confirm the required insulation type and thickness for the exact ordered product.

Black Rubber Insulation Features
Thermal Insulation
The insulation layer helps reduce heat transfer between the refrigerant tubing and the surrounding environment.
Moisture and Condensation Control
The current product information describes the Black Rubber material as functioning as both an insulation layer and a moisture-control layer.
Temperature Range
The listed Black Rubber insulation temperature range is -40°C to 120°C.
Test References
The current product information references ASTM E84, UL94, ASTM D1056 and ASTM G21 for insulation-related testing. Buyers requiring a specific test report or classification should confirm which documentation applies to the exact Black Rubber insulation configuration being ordered.
Installation Accessories
The current product information references an insulated copper line-set package that can include communication wire cable, a 3 m drain hose, wall pipe, wall cover and other installation parts.
Exact package contents should be confirmed specifically for the 50 ft 1/4" x 5/8" SKU before ordering, especially for distributor, contractor and project purchases.

Available Insulated Copper Line Set Sizes
DABUND supplies multiple copper tube combinations, insulation thicknesses and line-set lengths for different HVAC installation requirements.
| Copper Tube Size | Available Lengths | Black Rubber Insulation Options | Listed Flame Class |
|---|
| 1/4" + 3/8" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4" + 1/2" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4" + 5/8" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8" + 5/8" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8" + 3/4" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2" + 3/4" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8" + 7/8" | 3 m / 4 m / 5 m / 7 m / 10 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Note: The table above represents the wider DABUND insulated copper tubing range. This page specifically covers the 50 ft 1/4" x 5/8" configuration with 1/2" Black Rubber insulation.
1/4" x 5/8" Line Set for Compatible 24K–30K Systems
The current DABUND product information associates the 1/4" x 5/8" tubing combination with some approximately 2–2.5 ton or 24,000–30,000 BTU split air-conditioning systems.
This is a general product-family reference rather than a universal equipment compatibility rule.
Different HVAC models with the same nominal capacity can require different liquid and suction line sizes. Always verify the required refrigerant piping dimensions in the equipment manufacturer's installation manual.
Important Checks for a 50 Ft Refrigerant Line
Maximum Permitted Piping Length
Confirm that a 50 ft refrigerant piping route is within the maximum line length permitted by the specific HVAC equipment manufacturer.
Minimum Permitted Piping Length
Some HVAC systems also specify a minimum refrigerant-line length. Follow the manufacturer's requirements if the actual equipment-to-equipment route is substantially shorter.
Vertical Separation
If the indoor and outdoor units are installed at different elevations, confirm the maximum permitted vertical separation in the equipment installation documentation.
Piping Route and Bends
For longer or more complex routing with multiple bends, follow the equipment manufacturer's piping-layout requirements and permitted line-length criteria.
Additional Refrigerant
Check the equipment factory refrigerant charge and the piping length included in that charge. Some HVAC systems require additional refrigerant when the installed line exceeds the manufacturer's standard allowance.
Long-Line Installation Requirements
If the HVAC equipment manufacturer publishes specific long-line installation requirements, follow those instructions for the actual system.
How to Install a 50 Ft 1/4" x 5/8" Copper Line Set
Step 1: Confirm Equipment Compatibility
Check the HVAC equipment model and confirm that 1/4" x 5/8" is the required refrigerant-line size.
Step 2: Plan the 50 Ft Piping Route
Plan the route between the indoor and outdoor units and verify that the selected line length complies with the equipment manufacturer's piping limits.
Step 3: Inspect the Copper Tubing and Insulation
Inspect the tubing and Black Rubber insulation before installation and avoid crushing, sharp bends or insulation damage during routing.
Step 4: Inspect the Flared Ends
Check the factory-prepared flare surfaces and nuts before connecting them to compatible equipment service valves.
Step 5: Make the Refrigerant Connections
Follow the HVAC equipment manufacturer's flare-joint connection and tightening requirements.
Step 6: Leak Test and Evacuate
Complete the required leak testing and evacuation procedures according to the equipment manufacturer's installation instructions before system operation.
Step 7: Confirm Refrigerant Charge
Confirm whether the installed 50 ft piping length requires additional refrigerant according to the actual equipment manufacturer's instructions.
HVACR Applications
The 50 ft 1/4" x 5/8" insulated copper line set can be considered for compatible HVACR equipment that specifically requires this tubing combination and permits the selected piping length.
Compatible split air-conditioning systems
Compatible ductless mini split systems
Compatible heat-pump installations
HVAC equipment requiring 1/4" x 5/8" refrigerant tubing
Some compatible 24K–30K BTU applications
Projects requiring longer indoor-to-outdoor refrigerant piping routes
Compatibility must always be verified using the exact HVAC equipment model and installation documentation.
Information to Confirm Before Ordering
HVAC distributors, wholesalers, contractors and professional buyers should confirm the following information before placing an order:
Required copper tube size: 1/4" x 5/8"
Required line-set length: 50 ft
HVAC equipment model
Maximum permitted piping length
Vertical separation requirements
Refrigerant charge requirements
Required insulation type and thickness
Required package accessories
Order quantity
Packaging requirements
OEM or private-label requirements
DABUND Insulated Copper Tube Manufacturer
DABUND has produced insulated copper pipe, mini split line sets and related HVAC installation products since 2008.
Multiple copper tube size combinations, insulation configurations and line-set lengths are available for HVAC distributors, wholesalers, contractors and professional buyers.
OEM and ODM requirements can be discussed according to tubing size, insulation configuration, packaging and commercial order requirements.
DABUND Factory
DABUND produces insulated copper pipe, mini split line sets, aluminum pipe and related HVAC installation products.

Insulation Test References
The current product information references ASTM E84, UL94, ASTM D1056 and ASTM G21 for insulation-related testing.
Because different insulation materials and configurations are available, buyers requiring a particular report or classification should confirm that the requested documentation applies to the exact Black Rubber insulation configuration being ordered.

Exhibition
DABUND presents insulated copper line sets and related HVAC installation products at industry exhibitions for international customers and professional buyers.

Frequently Asked Questions
What size is this insulated copper line set?
This product uses 1/4" and 5/8" copper tubing.
How long is this copper line set?
This product is supplied in a 50 ft length.
What insulation is used on this 50 ft line set?
The current product information identifies this configuration with 1/2" Black Rubber insulation.
What copper standards are listed?
The current product information identifies ASTM B280 and C12200 DHP references for the copper tubing.
Are the copper tube ends flared?
Yes. Both copper tube ends are described as flared and supplied with nuts.
What is the listed temperature range for the Black Rubber insulation?
The current product information lists a Black Rubber insulation temperature range from -40°C to 120°C.
What system capacity commonly uses 1/4" x 5/8" tubing?
The current DABUND product information associates 1/4" x 5/8" tubing with some approximately 2–2.5 ton or 24,000–30,000 BTU split air-conditioning systems. This is only a general reference.
Can this line set be used with every 24,000 or 30,000 BTU air conditioner?
No. Different equipment models can require different refrigerant line sizes even when nominal capacities are similar. Confirm the required tubing sizes in the equipment installation manual.
Is a 50 ft line set suitable for every HVAC installation?
No. Confirm that 50 ft falls within the minimum and maximum refrigerant piping lengths permitted by the actual HVAC equipment manufacturer.
Does a 50 ft line require additional refrigerant?
It depends on the HVAC equipment. Check the factory refrigerant charge, included piping-length allowance and any refrigerant adjustment instructions provided by the manufacturer.
Does vertical separation matter with a 50 ft line set?
Yes. Confirm the permitted elevation difference between the indoor and outdoor units in the equipment manufacturer's installation documentation.
Do I need to follow long-line installation instructions?
If the HVAC equipment manufacturer publishes specific requirements for longer refrigerant piping, follow those instructions for the actual installation.
Can this copper line set be used with a heat pump?
It can be considered for compatible heat-pump equipment that specifically requires 1/4" x 5/8" refrigerant tubing and permits the selected line length.
Can this line set be used with VRF equipment?
Only where the applicable VRF system design specifically requires this tubing combination and permits the selected piping configuration.
What accessories can be supplied with this line set?
The current product information references communication wire cable, a 3 m drain hose, wall pipe, wall cover and other installation parts. Confirm the exact package contents for this 50 ft 1/4" x 5/8" SKU before ordering.
Are other copper tube sizes available?
Yes. The current product range includes 1/4" x 3/8", 1/4" x 1/2", 1/4" x 5/8", 3/8" x 5/8", 3/8" x 3/4", 1/2" x 3/4" and 3/8" x 7/8" combinations.
Can DABUND provide OEM or ODM insulated copper line sets?
Yes. OEM and ODM requirements can be discussed according to tubing size, insulation configuration, packaging and commercial order requirements.
Can I request a sample?
Sample requests are available according to the current sales policy. View sample information.
What payment terms are available?
Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.
What delivery terms are available?
Available international trade terms can include EXW, FOB, CFR and CIF.
What is the typical delivery time?
The current product information lists a typical delivery period of approximately 15–20 days. Actual lead time depends on order quantity, product configuration, customization and production schedule.