Home Copper Pipe Insulated Copper Pipe 50 Ft 1/4" X 3/8" Insulated Copper Pipe
50 Ft 1/4" X 3/8" Insulated Copper Pipe
50 Ft 1/4" X 3/8" Insulated Copper Pipe
50 Ft 1/4" X 3/8" Insulated Copper Pipe
50 Ft 1/4" X 3/8" Insulated Copper Pipe
50 Ft 1/4" X 3/8" Insulated Copper Pipe
50 Ft 1/4" X 3/8" Insulated Copper Pipe
50 Ft 1/4" X 3/8" Insulated Copper Pipe
50 Ft 1/4" X 3/8" Insulated Copper Pipe
50 Ft 1/4" X 3/8" Insulated Copper Pipe
50 Ft 1/4" X 3/8" Insulated Copper Pipe
50 Ft 1/4" X 3/8" Insulated Copper Pipe
50 Ft 1/4" X 3/8" Insulated Copper Pipe
1.Insulated Copper Pipe including one set air conditioner insulated copper pipe, size 1/4"+3/8" 50 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts. 
2. Both of the two copper pipe end do flaring and nuts. 
3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm. 
4. For the Insulated Copper Pipe, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m. 
5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200. 
6.Professional manufacturer of Insulated Copper Pipe, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 10M

Material

99.9% pure copper

Color

Black/White

Keywords

Insulated Copper Pipe

Application

HVAC
Inquire
Add to Basket

50 Ft 1/4" x 3/8" Insulated Copper Pipe

DABUND 50 Ft 1/4" x 3/8" Insulated Copper Pipe is a pre-insulated copper line set for compatible HVACR and split air-conditioning systems requiring 1/4-inch and 3/8-inch refrigerant tubing.

This configuration is supplied with 1/2" Black Rubber insulation according to the current product information. Both copper tubes have factory-prepared flared ends and nuts for compatible flare-type HVAC connections.

The copper tubing is identified with ASTM B280 and C12200 DHP references. The 50 ft length provides approximately 15.24 m of tubing for installations where the HVAC equipment manufacturer permits this piping length and the 1/4" x 3/8" tube combination.

Quick Answer: This is a 50 ft 1/4" x 3/8" pre-insulated copper line set with 1/2" Black Rubber insulation, flared copper ends and nuts for compatible HVACR installations.

Long-Line Selection Notice: A 50 ft refrigerant line requires more careful equipment compatibility checking than a short installation. Confirm the required liquid and suction line sizes, maximum permitted piping length, vertical separation, factory refrigerant charge and any additional refrigerant or long-line requirements before installation.

50 Ft 1/4" x 3/8" Copper Line Set Specifications

Product TypePre-Insulated Copper Pipe / Copper Line Set
Tube Size1/4" x 3/8"
Metric Outside Diameter6.35 mm x 9.52 mm
Length50 ft / approximately 15.24 m
Insulation1/2" Black Rubber
Copper Tube ReferenceASTM B280 / C12200 DHP
Tube End PreparationFlared ends with nuts
Black Rubber Temperature Range-40°C to 120°C according to current product information
General Capacity ReferenceSome 9K–12K BTU / approximately 0.75–1 ton systems; actual equipment specifications govern
Typical ApplicationCompatible HVACR and split AC systems requiring 1/4" x 3/8" tubing

50 Ft Pre-Insulated Copper Line Set

The 50 ft line set combines 1/4" and 3/8" copper tubing with factory-applied Black Rubber insulation for compatible HVAC installations requiring a longer refrigerant piping route.

Pre-insulated construction reduces the need to separately apply insulation around the refrigerant tubing at the job site and provides a consistent insulated piping configuration.

Because the 50 ft length is approximately 15.24 m, installers should verify the HVAC manufacturer's maximum piping length and long-line requirements before selecting this configuration.

ASTM B280 and C12200 Copper Tubing

DABUND identifies the copper tubing used in this product range with ASTM B280 and C12200 DHP references for HVACR copper tube applications.

The current product imagery also identifies the tubing as all-copper construction and describes the copper as 99.9% pure.

Required tube dimensions, wall thickness and system operating requirements should still be confirmed for the exact HVAC equipment and installation.

Factory-Prepared Flared Ends with Nuts

Both copper tubes are supplied with flared ends and nuts according to the current product information.

Inspect the flare surfaces before installation and verify that the flare dimensions, nuts and connection method match the equipment service valves.

Copper tubing for 50 ft 1/4 x 3/8 insulated copper line set

Copper Tube

Black Rubber insulation for 1/4 x 3/8 HVAC copper line set

Black Rubber Insulation

Factory-prepared flared copper tube ends for HVAC line set installation

Flared Ends

1/2" Black Rubber Insulation

This 50 ft 1/4" x 3/8" configuration is identified with 1/2" Black Rubber insulation in the current product information.

The insulation creates a thermal and moisture-control layer around the copper tubing and helps limit condensation on the insulated refrigerant line.

The current Black Rubber product information lists a temperature range from -40°C to 120°C.

Different insulation configurations are available across the wider product range. Confirm insulation material and thickness for the exact ordered product.

Black Rubber insulation around pre-insulated HVAC copper tubing

Black Rubber Insulation Features

Thermal Insulation

The insulation layer helps reduce heat transfer between the refrigerant tubing and the surrounding environment.

Moisture and Condensation Control

The current product information describes the insulation as providing both insulation and moisture protection to help control condensation around the copper tubing.

Temperature Range

The supplied Black Rubber insulation information lists a temperature range from -40°C to 120°C.

Test References

The current product information references ASTM E84, UL94, ASTM D1056 and ASTM G21 for insulation-related testing. Buyers requiring a particular test result or classification should confirm which documentation applies to the exact insulation configuration being ordered.

What Can Be Included with the 50 Ft Line Set?

The current product information references an installation package that may include communication wire cable, a 3 m drain hose, wall pipe, wall cover and other installation accessories.

Exact package contents should be confirmed for the 50 ft 1/4" x 3/8" SKU before ordering, particularly for distributor, contractor and project purchases.

Black Rubber insulated 1/4 x 3/8 copper pipe kit for HVAC installation

Available Insulated Copper Line Set Sizes

DABUND supplies multiple copper tube size combinations, insulation thicknesses and line-set lengths for different HVAC installation requirements.

Copper Tube SizeAvailable LengthsBlack Rubber Insulation OptionsListed Flame Class
1/4" + 3/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4" + 1/2"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4" + 5/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8" + 5/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8" + 3/4"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/2" + 3/4"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8" + 7/8"3 m / 4 m / 5 m / 7 m / 10 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1

1/4" x 3/8" Line Set for Compatible 9K–12K Systems

The current DABUND product information associates the 1/4" x 3/8" tubing combination with some approximately 0.75–1 ton or 9,000–12,000 BTU split air-conditioning systems.

This should be treated only as a general product-family reference and not as universal equipment compatibility.

Different mini split models with the same nominal BTU capacity can require different liquid and suction line sizes. Always confirm the exact piping requirements in the HVAC equipment installation manual.

Important Checks for a 50 Ft Refrigerant Line

Maximum Permitted Piping Length

Confirm that a 50 ft refrigerant-line route falls within the maximum piping length permitted by the specific equipment manufacturer.

Minimum Permitted Piping Length

Some systems also specify a minimum refrigerant-line length. Follow the equipment manufacturer's installation requirements if the actual route is significantly shorter than 50 ft.

Vertical Separation

Confirm the maximum permitted elevation difference between the indoor and outdoor units when the equipment is installed at different heights.

Equivalent Piping Length

For routes with multiple bends or complex piping arrangements, follow the equipment manufacturer's method for evaluating permitted piping length and layout.

Additional Refrigerant

Check the factory refrigerant charge and the piping length included in that charge. Some systems require additional refrigerant when the installed line exceeds the manufacturer's standard allowance.

Long-Line Installation Requirements

If the equipment manufacturer publishes specific instructions for longer refrigerant piping, follow those requirements for the actual system.

How to Prepare the 50 Ft Line Set for Installation

Step 1: Verify the Required Tube Sizes

Confirm that the actual HVAC equipment requires 1/4" and 3/8" refrigerant tubing.

Step 2: Plan the 50 Ft Piping Route

Measure and plan the route between the indoor and outdoor units and confirm that 50 ft complies with the equipment manufacturer's piping limits.

Step 3: Inspect the Copper Tubing and Insulation

Inspect the line set before installation and avoid damaging the copper tubing or insulation while routing it through the building structure.

Step 4: Inspect the Flared Ends

Check the factory-prepared flare surfaces and nuts before connecting them to the equipment service valves.

Step 5: Make the Refrigerant Connections

Follow the HVAC equipment manufacturer's flare-joint connection and tightening requirements.

Step 6: Leak Test and Evacuate

Complete the required leak testing and evacuation procedures according to the equipment manufacturer's installation instructions before system operation.

Step 7: Confirm Refrigerant Charge

Confirm whether the installed 50 ft piping length requires additional refrigerant according to the specific equipment documentation.

HVACR Applications

The 50 ft 1/4" x 3/8" insulated copper line set can be considered for compatible HVACR systems that specifically require this copper tube combination and permit the selected piping length.

  • Compatible ductless mini split systems

  • Compatible split air-conditioning systems

  • Compatible heat-pump installations

  • HVAC systems requiring 1/4" x 3/8" refrigerant tubing

  • Some compatible 9K–12K BTU installations

  • Projects requiring longer indoor-to-outdoor refrigerant-line routing

Compatibility must always be verified using the exact HVAC equipment model and installation documentation.

Information to Confirm Before Ordering

HVAC distributors, wholesalers, contractors and project buyers should confirm the following information before placing an order:

  • Required copper tube size: 1/4" x 3/8"

  • Required line-set length: 50 ft

  • HVAC equipment model

  • Maximum permitted piping length

  • Vertical separation requirements

  • Required insulation type and thickness

  • Required package accessories

  • Order quantity

  • Packaging requirements

  • OEM or private-label requirements

DABUND Insulated Copper Pipe Manufacturer

DABUND has produced insulated copper pipe, mini split line sets and related HVAC installation products since 2008.

Multiple copper tube size combinations, insulation configurations and line-set lengths are available for HVAC distributors, wholesalers, contractors and professional buyers.

OEM and ODM requirements can be discussed according to tubing size, insulation configuration, packaging and commercial order requirements.

DABUND Factory

DABUND produces insulated copper pipe, mini split line sets and related HVAC installation components.

DABUND factory production and packaging of insulated copper line sets

Insulation Test References

The current product information references ASTM E84, UL94, ASTM D1056 and ASTM G21 for insulation-related testing.

Because different insulation configurations are available, buyers requiring a particular report or classification should confirm the applicable test documentation for the exact product being ordered.

Test certificate for DABUND insulated copper pipe insulation

Exhibition

DABUND presents insulated copper line sets and related HVAC installation products at industry exhibitions for international customers and professional buyers.

DABUND insulated copper line sets displayed at HVAC industry exhibition

Frequently Asked Questions

What size is this insulated copper line set?

This product uses 1/4" and 3/8" copper tubing, equivalent to approximately 6.35 mm and 9.52 mm outside diameter.

How long is this copper line set?

This product is supplied in a 50 ft length, approximately 15.24 m.

What insulation is used on the 50 ft line set?

The current product information identifies this configuration with 1/2" Black Rubber insulation.

What copper standards are listed?

The current product information identifies ASTM B280 and C12200 DHP references for the copper tubing.

Are the copper tube ends flared?

Yes. The current product information states that both copper tube ends are flared and supplied with nuts.

What is the listed temperature range for the Black Rubber insulation?

The current product information lists a Black Rubber insulation temperature range of -40°C to 120°C.

What system capacity commonly uses 1/4" x 3/8" tubing?

The current DABUND product information associates 1/4" x 3/8" tubing with some approximately 0.75–1 ton or 9,000–12,000 BTU split air-conditioning systems. This is only a general reference.

Can this line set be used with every 9,000 or 12,000 BTU mini split?

No. Different equipment models can require different refrigerant line sizes even when their nominal capacities are similar. Confirm the required liquid and suction line sizes in the equipment installation manual.

Is a 50 ft line set suitable for every mini split?

No. Confirm that 50 ft is within the minimum and maximum refrigerant piping lengths permitted by the specific equipment manufacturer.

Does a 50 ft installation require additional refrigerant?

It depends on the HVAC system. Check the factory charge, included piping-length allowance and additional refrigerant requirements specified by the equipment manufacturer.

Does vertical separation matter with a 50 ft line set?

Yes. Confirm the permitted elevation difference between indoor and outdoor units in the HVAC equipment installation documentation.

Do I need to follow long-line instructions?

If the equipment manufacturer publishes specific requirements for longer refrigerant piping, follow those instructions for the actual system.

Can this copper line set be used with a heat pump?

It can be considered for compatible heat-pump equipment that specifically requires 1/4" x 3/8" tubing and permits the selected line length.

What accessories are included?

The current product information references communication wire cable, a 3 m drain hose, wall pipe, wall cover and other installation parts. Confirm the exact package contents for this 50 ft 1/4" x 3/8" SKU before ordering.

Are other copper tube sizes available?

Yes. The current product range includes 1/4" x 3/8", 1/4" x 1/2", 1/4" x 5/8", 3/8" x 5/8", 3/8" x 3/4", 1/2" x 3/4" and 3/8" x 7/8" combinations.

Are other insulation thicknesses available?

Yes. Multiple Black Rubber insulation thickness options are listed across the wider product range. Confirm the required insulation configuration for the exact order.

Can DABUND provide OEM or ODM insulated copper line sets?

Yes. OEM and ODM requirements can be discussed according to tubing size, insulation configuration, packaging and commercial order requirements.

Can I request a sample?

Sample requests are available according to the current sales policy. View sample information.

What payment terms are available?

Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.

What delivery terms are available?

Available international trade terms can include EXW, FOB, CFR and CIF.

What is the typical delivery time?

The current product information lists a typical delivery period of approximately 15–20 days. Actual lead time depends on order quantity, product configuration, customization and production schedule.

Related Products

1. 3/8" x 7/8" x 50 ft is the out dimension in inch. 9.52mm - 22.22mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.