-
DBJ-003
-
DABUND
-
Copper
-
1M - 50M
Material
Color
Keywords
Application
3/8 in. x 5/8 in. Mini Split Line Set
DABUND 3/8 in. x 5/8 in. Mini Split Line Set provides paired, pre-insulated copper refrigerant tubing for compatible ductless mini split air conditioners, heat pumps, commercial cooling systems and centralized HVAC applications.
The line set combines a 3/8 in. liquid line with a 5/8 in. suction line and is available in multiple production lengths for HVAC contractors, distributors and project buyers.
The source product information specifies 99.9% pure copper with ASTM B280 / C12200 referenced for the refrigerant tubing, together with factory-applied insulation for professional HVAC installation.
Quick Answer: This 3/8 x 5/8 mini split line set combines a 9.52 mm liquid line and 15.88 mm suction line with factory insulation for compatible medium- to higher-capacity HVAC systems. Standard production lengths include 15 m, 20 m, 25 m, 30 m and 50 m.
Mini Split Line Set Video
3/8 x 5/8 Mini Split Line Set Specifications
| Product Type | Pre-Insulated Copper Refrigerant Line Set |
| Line Set Size | 3/8 in. + 5/8 in. |
| Liquid Line | 3/8 in. / 9.52 mm |
| Suction Line | 5/8 in. / 15.88 mm |
| Available Lengths | 15 m / 20 m / 25 m / 30 m / 50 m |
| Copper Material | 99.9% Pure Copper |
| Copper Standard | ASTM B280 / C12200 |
| Featured Insulation | Black Rubber shown in product images and family table |
| Other Source-Listed Insulation | Polypropylene / Rubber Foam configurations are also referenced |
| Listed Temperature Range | -40°C to 120°C; confirm applicability to the exact insulation configuration |
| Source-Listed Pressure Range | 2100–7000 PSI; allowable pressure depends on tube diameter, wall thickness and temperature |
| Listed Refrigerants | R410A / R32; final compatibility must follow equipment specifications |
| Applications | Compatible Mini Split / Heat Pump / Commercial HVAC / Central HVAC Systems |
What Is a 3/8 x 5/8 Mini Split Line Set?
A 3/8 x 5/8 mini split line set is paired copper refrigerant piping used between compatible indoor and outdoor HVAC equipment.
The 3/8 in. tube functions as the liquid refrigerant line in the source configuration, while the 5/8 in. tube is identified as the suction return line.
Both tube diameters must match the exact piping requirements specified by the HVAC equipment manufacturer.
ASTM B280 C12200 Copper Refrigerant Tubing
The source product information specifies 99.9% pure copper and references ASTM B280 / C12200 for the refrigerant tubing.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible air-conditioning and refrigeration piping applications.
Suitable HVAC tube-bending methods and appropriate bend radii should be used to reduce the risk of kinking, flattening or restricting refrigerant flow.
Pressure Capability for R410A and R32 Applications
The source page lists a pressure range of 2100–7000 PSI and references R410A and R32 refrigerant applications.
Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and exact product configuration. Confirm the applicable tubing specification before installation.
Black Rubber Insulation
Black Rubber insulation is prominently shown in the source product images and wider mini split line-set family table.
The source describes the insulation as providing both thermal insulation and moisture protection around the copper refrigerant tubing.
Other sections of the source page reference Polypropylene / Rubber Foam configurations. Buyers should confirm the exact insulation material, thickness and project requirements for the ordered configuration.
Closed-Cell Insulation Structure
A closed-cell insulation structure helps reduce moisture penetration and surface condensation around cold refrigerant piping.
Listed Temperature Range
The Black Rubber insulation section lists a temperature range of approximately -40°C to 120°C. Confirm the applicable range for the exact insulation configuration ordered.
Copper Line Set and Insulation Video

99.9% Pure Copper

Black Rubber Insulated Pipe

Protective Plastic Cap
Black Rubber Insulation Detail
Black Rubber insulation acts as a thermal and moisture-resistant layer around the copper refrigerant tubing.
This helps reduce unwanted heat exchange and surface condensation around cold refrigerant lines when correctly specified and installed.

Compatible HVAC Applications
Compatible ductless mini split air conditioners
Heat-pump systems
Commercial HVAC installations
Centralized air-conditioning systems
HVAC equipment requiring a 3/8 in. liquid line and 5/8 in. suction line
Final compatibility must be confirmed from the HVAC equipment manufacturer's required refrigerant-line diameters, refrigerant type, operating conditions and permitted piping length.
General 36,000–48,000 BTU Capacity Reference
The wider DABUND product-family table lists the 3/8 in. + 5/8 in. configuration as a general reference for some 3.0–4.0 ton ductless mini split systems.
The same family information references approximately 36,000–48,000 BTU for this tubing combination.
An earlier section of the source page separately mentions 2–3 ton / 18,000–36,000 BTU. Because these source references conflict, capacity should not be used as the sole selection criterion. Final line-set sizing must follow the HVAC equipment manufacturer's exact pipe-size requirements.
How to Choose the Correct Line Set Length
Measure the Actual Piping Route
Measure the complete route between indoor and outdoor HVAC equipment before selecting a production length.
Select from Available Production Lengths
The wider product-family table lists standard production lengths of 15 m, 20 m, 25 m, 30 m and 50 m.
Verify Maximum Permitted Piping Length
The physical length of a copper coil does not determine the maximum refrigerant piping length permitted by the HVAC equipment. Always check the equipment manufacturer's specification.
Check Maximum Elevation Difference
If indoor and outdoor equipment are installed at different elevations, verify the maximum permitted vertical separation.
Check Additional Refrigerant Charge
Longer refrigerant runs may require additional refrigerant beyond the equipment's factory charge. Follow the HVAC manufacturer's charging instructions for the actual installed piping length.
Installation Guidelines
Confirm Exact Tube Diameters
Confirm that the equipment specifically requires a 3/8 in. liquid line and 5/8 in. suction line before installation.
Avoid Sharp Bends and Kinks
Use appropriate HVAC tube-bending methods and suitable bend radii to reduce the risk of copper tube deformation or restricted refrigerant flow.
Protect the Insulation
Avoid crushing, cutting or leaving unnecessary gaps in the insulation around bends, supports and wall penetrations.
Keep Copper Ends Protected
Keep open copper tube ends capped or sealed during storage and installation to reduce moisture and contamination entering the refrigerant circuit.
Pressure Test and Evacuate Before Startup
Follow the HVAC equipment manufacturer's pressure-testing, evacuation, refrigerant charging and commissioning procedures before system startup.
OEM and Customization Services
Custom production lengths from approximately 1 m to 50 m or more
Custom insulation thickness
Custom insulation material options
Logo printing on insulation
Bulk packaging for distributors and contractors
OEM and ODM configurations
Custom configurations are intended for HVAC distributors, contractors, wholesalers and private-label buyers.
Black Rubber Mini Split Line Set

Available Mini Split Line Set Sizes
| Size | Available Lengths | Black Rubber Insulation | Listed Flame-Resistance Options |
|---|---|---|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
General Line Set Size and Capacity Reference
| Line Set Size | General Ton Reference | General BTU Reference |
|---|---|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
These capacity values are general product-family references only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact technical requirements.
DABUND Mini Split Line Set Manufacturing
DABUND manufactures mini split line sets, insulated copper pipe and related HVAC components for distributors, contractors and project buyers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations reference ASTM E84, UL94, ASTM D1056 and ASTM G21.
Buyers requiring compliance documentation should confirm the exact insulation material, thickness and corresponding test report for the ordered configuration.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where professional buyers can review mini split line sets, insulated copper tubing and related HVAC products.

Frequently Asked Questions
What is a 3/8 x 5/8 mini split line set used for?
It is used as refrigerant piping between compatible indoor and outdoor HVAC equipment requiring a 3/8 in. liquid line and 5/8 in. suction line.
What size HVAC system can use a 3/8 x 5/8 line set?
The wider DABUND product-family table lists 3/8 x 5/8 as a general reference for some 3.0–4.0 ton or 36,000–48,000 BTU systems. Final tubing size must follow the equipment manufacturer's exact specification.
What lengths are available?
The source product-family table lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths.
What copper material is used?
The source product information specifies 99.9% pure copper and references ASTM B280 / C12200.
What insulation is shown on this product?
The product images and wider family table prominently show Black Rubber insulation. Other technical sections reference Polypropylene / Rubber Foam configurations, so the exact ordered configuration should be confirmed.
What insulation thicknesses are available?
The wider Black Rubber product family lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thickness options.
What is the listed insulation temperature range?
The Black Rubber insulation description lists approximately -40°C to 120°C. Confirm the applicable range for the exact insulation configuration ordered.
Is this line set compatible with R410A and R32?
R410A and R32 are referenced in the source product information. Final compatibility must be confirmed against the HVAC equipment manufacturer's refrigerant, pipe-size and operating-pressure requirements.
What is the pressure rating?
The source page lists a pressure range of 2100–7000 PSI. Actual allowable pressure depends on tube diameter, wall thickness, operating temperature and exact product configuration.
Can this mini split line set be used outdoors?
UV-resistant insulation configurations are referenced on the source page. Final outdoor suitability should be confirmed for the exact insulation material and environmental exposure conditions.
What are the advantages of pre-insulated copper line sets?
Factory-applied insulation reduces additional field insulation work, helps limit thermal exchange and reduces surface condensation around cold refrigerant piping.
How do I choose the correct line set length?
Measure the actual piping route and confirm the HVAC equipment manufacturer's maximum piping length, maximum elevation difference and refrigerant-charge requirements before selecting a coil length.
Can DABUND customize the mini split line set?
Yes. The source page lists custom lengths, insulation thickness and material options, logo printing and bulk packaging for distributor and OEM orders.
Is professional HVAC installation recommended?
Yes. Refrigerant piping should be installed, leak-tested, evacuated, charged and commissioned according to the HVAC equipment manufacturer's instructions and applicable local requirements.

