50 Ft 3/8" x 5/8" Pre-Insulated Copper Tube
DABUND 50 ft 3/8" x 5/8" pre-insulated copper tube is a paired HVAC refrigerant line set for compatible mini split air conditioners, heat pumps, split AC systems and refrigeration applications.
The product combines two copper refrigerant tubes with factory-applied insulation to reduce primary on-site insulation work and provide a coordinated refrigerant piping solution for professional HVAC installations.
The paired copper tubing includes one 3/8" tube and one 5/8" tube, equivalent to approximately 9.52 mm and 15.88 mm outside diameter. The total coil length is 50 ft / approximately 15.24 m.
Copper tubing is manufactured from C12200 DHP copper for air-conditioning and refrigeration applications, with ASTM B280 specifications available according to the ordered configuration.
Black Rubber / NBR insulation options are available in multiple thicknesses, together with OEM printing and private-label packaging for HVAC wholesalers, distributors and brands.
Compatibility Notice: Refrigerant line dimensions and allowable piping length vary by HVAC manufacturer and model. Confirm the required tube sizes, minimum and maximum piping length, equivalent length, vertical separation, insulation requirements and refrigerant-charging instructions before installation.
50 Ft 3/8" x 5/8" Copper Line Set Specifications
| Product Type | Pre-Insulated Copper Tube / HVAC Line Set |
| Tube Size | 3/8" + 5/8" |
| Metric Outside Diameter | Approximately 9.52 mm + 15.88 mm |
| Length | 50 ft / approximately 15.24 m |
| Copper Material | C12200 DHP Copper |
| Copper Tube Specification | ASTM B280 specification available |
| Insulation | Black Rubber / NBR options |
| Insulation Thickness | 8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm options |
| Temperature Range | Selected insulation specifications from approximately -40°C to 120°C |
| Applications | Compatible mini split AC, heat pump, split AC and refrigeration systems |
| OEM Options | Tube size, coil length, insulation, printing and packaging |
Key Features of the 50 Ft Pre-Insulated Copper Tube
C12200 Copper for HVAC and Refrigeration
DABUND uses C12200 DHP copper tubing for HVAC and refrigeration applications. The copper provides the formability and thermal properties required for professional refrigerant piping installations.
ASTM B280 Copper Tubing Specification
ASTM B280 copper tube specifications are available for air-conditioning and refrigeration applications according to the ordered product configuration. Buyers can confirm dimensional, wall-thickness and testing requirements before bulk ordering.
3/8" x 5/8" Paired Refrigerant Tubing
The line set combines 3/8" and 5/8" outside-diameter copper tubes. These correspond to approximately 9.52 mm and 15.88 mm. Their liquid-line and suction-line functions must match the exact HVAC equipment specification.
50 Ft Continuous Copper Line Set
The 50 ft / 15.24 m continuous coil provides more routing flexibility than shorter 10 ft or 25 ft line sets. Where permitted by the HVAC equipment manufacturer, a continuous line can reduce the number of intermediate connections required along the refrigerant piping route.
Factory-Applied Black Rubber Insulation
Factory-applied closed-cell insulation helps reduce unwanted heat transfer and surface condensation while providing physical protection around the copper tubing. Multiple insulation thicknesses are available for different climates and project specifications.
OEM Printing and Private-Label Supply
DABUND can customize insulation printing with company name, copper tube size, coil length and other product information. OEM packaging and private-label options are available for HVAC distributors, wholesalers and brands.

High-Purity Copper Tubing

Black Rubber Insulated Pipe

Protective Plastic Caps
Black Rubber Pipe Insulation Performance
The closed-cell insulation surrounding the copper tubing is designed to reduce unwanted thermal transfer, control surface condensation and protect refrigerant piping during HVAC installation and operation.
Closed-cell construction helps reduce moisture penetration
Low thermal conductivity helps reduce unwanted heat gain and heat loss
Insulation functions as both a thermal layer and moisture-resistant layer
UV-resistant insulation options are available for outdoor exposure
Multiple insulation thicknesses are available for different project requirements
Selected specifications support operating temperatures from approximately -40°C to 120°C

Thermal Insulation
The high-density closed-cell structure helps reduce unwanted heat transfer between the refrigerant tubing and surrounding air.
Condensation and Moisture Control
Correctly specified insulation helps reduce condensation on cold refrigerant lines and moisture penetration around the piping.
UV and Weather Resistance
UV-resistant insulation options are available for installations where portions of the refrigerant line are exposed outdoors. Additional line-set covering or mechanical protection may be appropriate for prolonged exposure depending on project requirements.
Insulation Testing Options
Depending on the selected insulation material and specification, test documentation can reference ASTM E84, UL 94, ASTM D1056 and ASTM G21. Buyers should confirm the exact material grade and applicable test report for the ordered configuration.
When Should You Choose a 50 Ft HVAC Line Set?
A 50 ft pre-insulated copper line set is useful for compatible installations where shorter 10 ft, 20 ft or 25 ft line sets do not provide enough routing length between the indoor and outdoor HVAC equipment.
Typical routes may pass through walls, ceilings, attics, mechanical rooms or around structural obstacles before reaching the outdoor condenser or heat-pump unit.
Using one continuous 50 ft coil can reduce the number of intermediate connections required compared with combining several shorter copper sections when continuous piping is permitted by the equipment manufacturer.
Installers should not automatically use the entire 50 ft coil. Confirm the equipment manufacturer's minimum and maximum piping length, equivalent length, vertical lift and refrigerant-charge requirements before cutting or installing the tubing.
50 Ft Copper Line Set for HVAC Wholesalers and Distributors
DABUND supplies pre-insulated copper tubing to HVAC wholesalers, refrigeration distributors, importers, contractors, project suppliers and private-label brands.
The 50 ft configuration provides a practical inventory option for customers serving compatible residential, commercial and light-commercial HVAC installations.
Buyers can customize copper tube sizes, line lengths, insulation thickness, insulation printing and packaging according to target-market requirements.
OEM services are suitable for HVAC brands requiring company names, dimensions, length markings or other identification printed directly on the insulation.

Available Pre-Insulated Copper Tube Sizes
DABUND manufactures multiple paired copper tube combinations, insulation thicknesses and coil lengths for HVAC and refrigeration applications.
| Size | Available Length | Black Rubber Insulation | Flame-Resistant Options |
| 1/4 + 3/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/4 + 1/2 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/4 + 5/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 5/8 | 50 ft / 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 3/4 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/2 + 3/4 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 7/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
Is a 3/8" x 5/8" Line Set Compatible With My HVAC System?
A 3/8" x 5/8" refrigerant line set is used by certain mini split air conditioners, heat pumps and split HVAC systems. The correct copper tube dimensions should not be selected solely by nominal BTU capacity or tonnage.
The 3/8" copper tube has an outside diameter of approximately 9.52 mm, while the 5/8" tube has an outside diameter of approximately 15.88 mm. Verify that these dimensions match the exact indoor and outdoor equipment combination.
Some HVAC equipment may use 3/8" and 5/8" tubing in mid-capacity applications, but different manufacturers can specify different pipe sizes for systems with similar capacities. Always follow the equipment installation manual.
Before installation, also confirm maximum actual line length, equivalent length, vertical separation, insulation thickness, refrigerant type and additional refrigerant-charge requirements.
Refrigerant piping, brazing, pressure testing, evacuation and refrigerant charging should be completed by qualified HVAC personnel according to applicable requirements and equipment manufacturer instructions.
OEM Pre-Insulated Copper Tube Manufacturer
DABUND has manufactured insulated copper tubing, mini split line sets and HVAC components since 2008. The company supplies products to HVAC wholesalers, distributors, importers, contractors and private-label brands.
Available OEM and ODM options include:
Customized copper tube dimensions
Customized coil lengths
Customized insulation thickness
Company name and specification printing
Customized insulation configuration
Private-label cartons and export packaging
Bulk supply for distributors and wholesalers
Why Choose DABUND Pre-Insulated Copper Tubing?
HVAC copper tubing manufacturing experience since 2008
C12200 DHP copper for air-conditioning and refrigeration applications
ASTM B280 copper tubing specifications available
Factory-applied insulation
Multiple paired copper tube sizes
Multiple coil lengths and insulation thicknesses
OEM insulation printing and private-label services
Bulk production for HVAC wholesalers and distributors
DABUND Factory
DABUND manufactures insulated copper pipes, mini split line sets, aluminum pipes and HVAC components for international B2B customers.

SGS Testing and Insulation Standards
Depending on the selected insulation specification, test documentation can reference ASTM E84, UL 94, ASTM D1056 and ASTM G21. Buyers should confirm the exact insulation grade and applicable test report required for the ordered configuration.

International HVAC Exhibitions
DABUND participates in international exhibitions to present pre-insulated copper tubing, refrigerant line sets and HVAC components to distributors, contractors, importers and industry buyers.

Frequently Asked Questions
What is a 50 ft 3/8" x 5/8" pre-insulated copper tube?
It is a paired HVAC refrigerant line set containing 3/8" and 5/8" copper tubing with factory-applied insulation. The total coil length is approximately 50 ft / 15.24 m.
What are the metric sizes of 3/8" and 5/8" copper tubing?
A 3/8" copper tube has an outside diameter of approximately 9.52 mm, while a 5/8" copper tube has an outside diameter of approximately 15.88 mm.
How long is a 50 ft copper line set in meters?
50 ft is approximately 15.24 meters.
Why choose a 50 ft line set?
A 50 ft line set provides more routing flexibility than shorter 10 ft, 20 ft or 25 ft coils and can reduce the number of intermediate copper joints required when the HVAC manufacturer permits the planned continuous refrigerant route.
Can every mini split use a 50 ft refrigerant line?
No. Maximum and minimum piping lengths vary by manufacturer and model. Always verify the equipment installation manual before purchasing or installing a 50 ft line set.
What copper material does DABUND use?
DABUND uses C12200 DHP copper for HVAC and refrigeration applications, with ASTM B280 copper tubing specifications available according to the ordered configuration.
What insulation options are available?
Black Rubber / NBR insulation is available in multiple thicknesses including 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm according to the ordered configuration. Other insulation configurations can be discussed for OEM orders.
Does the insulation help reduce condensation?
Yes. Closed-cell insulation helps reduce moisture penetration and surface condensation when the correct insulation thickness is selected and properly installed.
Can DABUND print my company name on the insulation?
Yes. OEM printing can include company name, tube size, coil length and other product information according to customer requirements.
Can DABUND customize other copper line set sizes?
Yes. Available paired tube combinations include 1/4" + 3/8", 1/4" + 1/2", 1/4" + 5/8", 3/8" + 5/8", 3/8" + 3/4", 1/2" + 3/4" and 3/8" + 7/8", with multiple lengths available.
Can I get samples before placing a bulk order?
Yes. DABUND provides sample support for product evaluation before wholesale or OEM orders.
What payment terms are available?
Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the order and commercial agreement.
What delivery terms are available?
Available international trade terms can include EXW, FOB, CFR and CIF. Buyers can confirm the preferred Incoterm when requesting a quotation.
What is the typical production lead time?
Standard production lead time is typically around 15–20 days. Actual lead time depends on order quantity, customization requirements, material availability and production schedule.