DBJ-003
DABUND
Copper
1M - 50M
1/4,3/8,1/2,5/8,3/4,7/8,1,1-1/8
| Material: | |
|---|---|
| Color: | |
| Keywords: | |
| Application: | |
| Insulation Thickness: | |
| Market: | |
| Availability: | |
| Quantity: | |
Premium 82 ft insulated copper tube with factory-applied insulation — engineered for HVAC applications including mini split, ductless air conditioners, heat pumps, and other refrigerant line installations where extended length and reliable performance are required.
The 3/4 in × 1/2 in × 82 ft insulated copper tube combines high-quality copper tubing with factory-applied insulation to provide strong thermal protection, reduced condensation, and enhanced system efficiency. This long, pre-insulated line set is ideal for installations where indoor and outdoor units are separated by moderate to long distances.
Long 82 ft tubing ideal for large homes, multi-story buildings, and rooftop units
Reduces the need for couplings or additional line extensions
Supports flexible routing for challenging installations
3/4 in suction line for return refrigerant gas
1/2 in liquid line for refrigerant feed
Common size pairing for HVAC and ductless AC systems
Pre-insulated tubing maintains stable refrigerant temperatures along long runs, reducing thermal loss and supporting optimal system performance.
The insulation layer helps prevent condensation buildup on copper lines, protecting walls, ceilings, and structural components from water damage and mold growth.
The factory-applied insulation jacket is UV-resistant, weather-stable, and suitable for outdoor line exposure, extending the lifespan of the tubing under varied climate conditions.
Built with 99.9% pure copper, this line set delivers excellent:
Thermal conductivity
Corrosion resistance
Mechanical strength for high-pressure HVAC operations
Designed to meet HVAC copper line specifications and standards, ensuring safe refrigerant flow and compatibility with modern HVAC equipment.
● Pipe Insulation, Material Black Rubber, Temp Range -40 Degrees to 120 Degrees.
● The pipe insulation has a better function of moisture condensation. Insulation material is both the insulation layer and moisture-proof layer.
● There is no need to drop the water vapor permeation protective layer so that it has a better moisture condensation function.

This insulated copper tube is widely used in:
Mini split air conditioners
Ductless heat pump installations
Residential & light commercial HVAC systems
Compatible with commonly used refrigerants such as R410A, R32, and others, meeting typical pressure and performance requirements for current HVAC systems.
Factory insulation eliminates the need for on-site wrapping, saving installation time and reducing labor costs while ensuring consistent insulation quality.
Improved thermal performance reduces energy loss, helping the HVAC unit operate more efficiently and potentially lowering energy consumption.
Proper insulation minimizes surface condensation and prevents moisture issues that can lead to mold or structural deterioration.
| Feature | Detail |
|---|---|
| Line Length | 82 ft (24.99 m) |
| Line Sizes | 1/2 in (Liquid) × 3/4 in (Suction) |
| Material | 99.9% Pure Copper |
| Insulation | Factory-applied, UV-resistant |
| Application | HVAC systems, Mini Split, Ductless AC |
| Refrigerants | R410A, R32, and similar HVAC refrigerants |
Measure the total distance between indoor and outdoor units to ensure the 82 ft length is appropriate and allows smooth routing without excessive bending.
Use a wall pipe sleeve where the tubing passes through walls or structures to avoid insulation damage and maintain airtight sealing.
Use line clamps or HVAC support brackets to secure long runs of tubing, reduce vibration, and prevent sagging that might stress insulation or copper tubing.

Size | Length | Insulation Black Rubber | Flame Resistant |
1/4+3/8 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
1/4+1/2 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
1/4+5/8 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
3/8+5/8 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
3/8+3/4 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
1/2+3/4 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
3/8+7/8 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
With premium 99.9% pure copper, factory-applied insulation, and extended 82 ft length, this insulated copper tube delivers reliable HVAC performance, simplified installation, and long-term system efficiency — ideal for mini split, ductless AC, and other HVAC applications.



1.Q:What is your payment terms?
A:TT,L/C AT SIGHT,CREDIT CARD etc
2.Q:What is your delivery terms?
A:EXW, FOB, CFR, CIF etc
3.Q:Are you trading company or manufacturer?
A:Manufacturer
4.Q:May I get a sample?
A:Yes, we can send you 3pieces
You just charge for the express cost is ok.
5.Q:Can I print my logo?
A:Yes of cause, we accept OEM and ODM.
6.Q:How long is your delivery time?
A:Usually 15-20days, if urgent, we can arrange to do in advance and delivery fast.
It refers to the outer diameters of the refrigerant lines: 3/4 in for the suction line and 1/2 in for the liquid line, a common configuration for many HVAC and ductless systems.
Yes — the factory-applied UV-resistant insulation is designed for outdoor exposure and protects the copper tubing from weather and sunlight.
No — this product comes with factory-installed insulation that meets most HVAC installation requirements, eliminating the need for additional field insulation.
Yes — the copper line set is compatible with common refrigerants such as R410A and R32, meeting standard pressures and system requirements.
Premium 82 ft insulated copper tube with factory-applied insulation — engineered for HVAC applications including mini split, ductless air conditioners, heat pumps, and other refrigerant line installations where extended length and reliable performance are required.
The 3/4 in × 1/2 in × 82 ft insulated copper tube combines high-quality copper tubing with factory-applied insulation to provide strong thermal protection, reduced condensation, and enhanced system efficiency. This long, pre-insulated line set is ideal for installations where indoor and outdoor units are separated by moderate to long distances.
Long 82 ft tubing ideal for large homes, multi-story buildings, and rooftop units
Reduces the need for couplings or additional line extensions
Supports flexible routing for challenging installations
3/4 in suction line for return refrigerant gas
1/2 in liquid line for refrigerant feed
Common size pairing for HVAC and ductless AC systems
Pre-insulated tubing maintains stable refrigerant temperatures along long runs, reducing thermal loss and supporting optimal system performance.
The insulation layer helps prevent condensation buildup on copper lines, protecting walls, ceilings, and structural components from water damage and mold growth.
The factory-applied insulation jacket is UV-resistant, weather-stable, and suitable for outdoor line exposure, extending the lifespan of the tubing under varied climate conditions.
Built with 99.9% pure copper, this line set delivers excellent:
Thermal conductivity
Corrosion resistance
Mechanical strength for high-pressure HVAC operations
Designed to meet HVAC copper line specifications and standards, ensuring safe refrigerant flow and compatibility with modern HVAC equipment.
● Pipe Insulation, Material Black Rubber, Temp Range -40 Degrees to 120 Degrees.
● The pipe insulation has a better function of moisture condensation. Insulation material is both the insulation layer and moisture-proof layer.
● There is no need to drop the water vapor permeation protective layer so that it has a better moisture condensation function.

This insulated copper tube is widely used in:
Mini split air conditioners
Ductless heat pump installations
Residential & light commercial HVAC systems
Compatible with commonly used refrigerants such as R410A, R32, and others, meeting typical pressure and performance requirements for current HVAC systems.
Factory insulation eliminates the need for on-site wrapping, saving installation time and reducing labor costs while ensuring consistent insulation quality.
Improved thermal performance reduces energy loss, helping the HVAC unit operate more efficiently and potentially lowering energy consumption.
Proper insulation minimizes surface condensation and prevents moisture issues that can lead to mold or structural deterioration.
| Feature | Detail |
|---|---|
| Line Length | 82 ft (24.99 m) |
| Line Sizes | 1/2 in (Liquid) × 3/4 in (Suction) |
| Material | 99.9% Pure Copper |
| Insulation | Factory-applied, UV-resistant |
| Application | HVAC systems, Mini Split, Ductless AC |
| Refrigerants | R410A, R32, and similar HVAC refrigerants |
Measure the total distance between indoor and outdoor units to ensure the 82 ft length is appropriate and allows smooth routing without excessive bending.
Use a wall pipe sleeve where the tubing passes through walls or structures to avoid insulation damage and maintain airtight sealing.
Use line clamps or HVAC support brackets to secure long runs of tubing, reduce vibration, and prevent sagging that might stress insulation or copper tubing.

Size | Length | Insulation Black Rubber | Flame Resistant |
1/4+3/8 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
1/4+1/2 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
1/4+5/8 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
3/8+5/8 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
3/8+3/4 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
1/2+3/4 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
3/8+7/8 | 15m/20m/25m/30m/50m | 8mm/9mm/10mm/13mm/19mm/25.4mm | M1/B1 |
With premium 99.9% pure copper, factory-applied insulation, and extended 82 ft length, this insulated copper tube delivers reliable HVAC performance, simplified installation, and long-term system efficiency — ideal for mini split, ductless AC, and other HVAC applications.



1.Q:What is your payment terms?
A:TT,L/C AT SIGHT,CREDIT CARD etc
2.Q:What is your delivery terms?
A:EXW, FOB, CFR, CIF etc
3.Q:Are you trading company or manufacturer?
A:Manufacturer
4.Q:May I get a sample?
A:Yes, we can send you 3pieces
You just charge for the express cost is ok.
5.Q:Can I print my logo?
A:Yes of cause, we accept OEM and ODM.
6.Q:How long is your delivery time?
A:Usually 15-20days, if urgent, we can arrange to do in advance and delivery fast.
It refers to the outer diameters of the refrigerant lines: 3/4 in for the suction line and 1/2 in for the liquid line, a common configuration for many HVAC and ductless systems.
Yes — the factory-applied UV-resistant insulation is designed for outdoor exposure and protects the copper tubing from weather and sunlight.
No — this product comes with factory-installed insulation that meets most HVAC installation requirements, eliminating the need for additional field insulation.
Yes — the copper line set is compatible with common refrigerants such as R410A and R32, meeting standard pressures and system requirements.