100 ft 1/4 in. x 3/8 in. Pre-Insulated Copper Pipe
DABUND 100 ft 1/4 in. x 3/8 in. Pre-Insulated Copper Pipe provides an extended refrigerant piping solution for compatible mini split air conditioners, heat pumps, HVAC systems and refrigeration installations.
The paired copper tubing combines a 1/4 in. liquid line with a 3/8 in. suction line and provides a continuous 100 ft length for projects where indoor and outdoor equipment are positioned farther apart.
Manufactured from 99.9% pure copper with ASTM B280 / C12200 referenced in the source product information, the tubing is supplied with factory-applied White PE insulation to help reduce thermal exchange, condensation and additional field insulation work.
Quick Answer: This 100 ft 1/4 x 3/8 pre-insulated copper pipe combines ASTM B280 copper tubing with White PE / IXPE insulation for compatible long-run mini split, heat-pump and HVAC installations.
100 ft Pre-Insulated Copper Pipe Video
100 ft 1/4 x 3/8 Copper Pipe Specifications
| Product Type | Pre-Insulated Copper Refrigerant Line Set |
| Pipe Size | 1/4 in. x 3/8 in. |
| Liquid Line | 1/4 in. / 6.35 mm |
| Suction Line | 3/8 in. / 9.52 mm |
| Length | 100 ft / approximately 30.5 m |
| Copper Material | 99.9% Pure Copper |
| Copper Standard | ASTM B280 / C12200 as referenced in source product information |
| Featured Insulation | White PE / IXPE Foam |
| Insulation Structure | UV-Resistant PE Outer Layer / IXPE Foam / Closed-Cell Inner Layer |
| Source-Listed Temperature Range | -40°C to 120°C; confirm applicability to the ordered insulation configuration |
| Source-Listed Pressure Range | 2100–7000 PSI; confirm the applicable value for the exact tubing dimensions and wall thickness |
| Listed Refrigerants | R410A and R32; final compatibility must follow HVAC equipment specifications |
| Applications | Compatible Mini Split, Heat Pump, HVAC and Refrigeration Systems |
100 ft Long Copper Line Set for HVAC Installations
The 100 ft continuous copper line provides additional routing flexibility where compatible indoor and outdoor HVAC equipment are separated by a greater distance.
Typical project layouts may include multi-story homes, apartments, extended residential installations and other building layouts where shorter refrigerant piping does not provide sufficient reach.
A continuous coil can reduce unnecessary intermediate joints, provided the total installed piping length remains within the HVAC equipment manufacturer's specified limits.
1/4 in. Liquid Line and 3/8 in. Suction Line
The paired copper tubing combines a 1/4 in. liquid refrigerant line with a 3/8 in. suction return line.
Before ordering, verify that the selected mini split, heat-pump or refrigeration system specifically requires these exact refrigerant-line dimensions.
Refrigerant piping should not be selected only by nominal BTU or tonnage because required tube sizes can vary between HVAC manufacturers and individual equipment models.
ASTM B280 C12200 Copper Refrigerant Tubing
The source product information specifies 99.9% pure copper and references ASTM B280 refrigeration tubing and C12200 copper.
Copper provides thermal conductivity, corrosion resistance and flexibility for routing compatible HVAC refrigerant piping.
The source also describes the tubing as suitable for bending during installation. Appropriate HVAC tube-bending tools and bend radii should be used to reduce the risk of kinking or tube deformation.
Pressure Capability for R410A and R32 Applications
The source product information lists a pressure range of 2100–7000 PSI and references R410A and R32 refrigerant applications.
Actual allowable pressure depends on tube diameter, wall thickness, operating temperature and the exact ordered configuration. Confirm the applicable tubing specification before using the line set in a particular HVAC system.
White PE Pre-Insulated Copper Pipe
The featured product configuration uses White PE insulation around the copper refrigerant tubing.
Factory-applied insulation helps reduce unwanted thermal exchange and condensation while reducing additional field insulation work.
Copper Pipe and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Protective Plastic Cap
White PE Embossed Insulation
The White PE outer layer provides a protective surface around the thermal insulation and helps protect the tubing during compatible HVAC installation and service.

Insulation Production and Structure

Insulation Pipe Production

Insulation Pipe Warehouse

Inner Layer Insulated Pipe
Three-Layer Insulation Structure
UV-Resistant PE Outer Layer
The source product information describes a UV-resistant PE outer film designed to protect the insulation against environmental exposure.
IXPE Foam Middle Layer
The middle IXPE foam layer provides thermal insulation and cushioning around the copper tubing.
Closed-Cell Inner Layer
The closed-cell inner insulation structure helps limit moisture penetration and reduce condensation around cold refrigerant piping.
Condensation and Moisture Control
Proper insulation coverage helps reduce surface condensation and protects the refrigerant line from unnecessary moisture exposure.
Insulation Detail

Compatible HVAC and Refrigeration Applications
Compatible ductless mini split air conditioners
Heat-pump systems
Residential HVAC installations
Central air-conditioning systems requiring this pipe size
Compatible refrigeration systems
Extended refrigerant piping projects
Final compatibility should be confirmed from the equipment manufacturer's required liquid-line size, suction-line size, refrigerant, maximum piping length, elevation limits and operating-pressure requirements.
General 9,000–12,000 BTU Capacity Reference
The wider DABUND product family lists the 1/4 in. + 3/8 in. configuration as a general reference for some 0.75–1.0 ton or 9,000–12,000 BTU mini split systems.
This is a general sizing reference only. Final pipe selection must follow the HVAC equipment manufacturer's exact liquid-line and suction-line specifications.
Flexible Copper Tubing for HVAC Installation
The paired copper tubing is supplied in a flexible coiled format for routing through compatible walls, ceilings and building structures.
Suitable HVAC bending methods should be used to reduce the risk of kinking or flattening the tubing and to maintain an appropriate refrigerant path.
OEM and Custom Supply Options
DABUND lists customization options for distributors, importers, HVAC brands and project buyers.
Custom pipe-size combinations
Custom production lengths
Multiple insulation thicknesses
Logo printing on insulation
Private-label branding
Custom packaging
Bulk production support

Available Pre-Insulated Copper Pipe Sizes
| Size | Available Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: The wider product family lists standard production lengths of 15 m, 20 m, 25 m, 30 m and 50 m. This specific SKU is 100 ft, approximately 30.5 m, so buyers should specify the exact finished 100 ft length when ordering.
General Line Set Size and Capacity Reference
The following capacity ranges are general references from the wider DABUND product family. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact piping requirements.
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
For the 1/4 x 3/8 configuration, the wider DABUND product family lists 0.75–1.0 ton and 9,000–12,000 BTU as general references. Actual compatibility must be confirmed from the equipment manufacturer's exact liquid-line and suction-line requirements.
Critical Checks for a 100 ft Refrigerant Run
Verify Maximum Permitted Piping Length
Confirm that the specific mini split, heat-pump or HVAC system permits at least the required 100 ft refrigerant piping route.
Confirm the Exact Pipe Sizes
Verify that the selected equipment specifically requires a 1/4 in. liquid line and 3/8 in. suction line.
Check Maximum Elevation Difference
For multi-story or rooftop installations, verify the maximum allowable vertical separation between the indoor and outdoor equipment.
Check Additional Refrigerant Requirements
A 100 ft piping run may require additional refrigerant beyond the equipment's factory charge. Follow the equipment manufacturer's charging instructions for the actual installed line length.
Provide Proper Pipe Support
Use appropriate HVAC-rated supports, clips or straps to reduce sagging, vibration and mechanical stress on the copper tubing and insulation.
Installation Guidelines
Plan the Complete Refrigerant Route
Measure and plan the complete piping route before uncoiling or cutting the copper tubing.
Avoid Sharp Bends and Kinks
Use suitable tube-bending tools and appropriate bend radii to reduce the risk of copper tube deformation or restricted refrigerant flow.
Keep Pipe Ends Sealed
Keep open copper tube ends protected during storage and installation to reduce moisture and contamination entering the refrigerant system.
Protect the Insulation
Avoid crushing, cutting or leaving unnecessary gaps in the insulation, especially around bends, supports and wall penetrations.
Use Correct Connection Procedures
Follow the HVAC equipment manufacturer's approved cutting, flaring, brazing and connection procedures for the selected system.
Pressure Test and Evacuate Before Startup
Follow the equipment manufacturer's approved pressure-testing, evacuation, refrigerant charging and commissioning procedures before system startup.
Why Choose DABUND Pre-Insulated Copper Pipe?
ASTM B280 Copper Tubing
The source product information specifies high-purity copper and references ASTM B280 / C12200.
White PE / IXPE Insulation
The featured insulation combines a White PE exterior with IXPE foam and a closed-cell inner structure.
100 ft Long-Length Supply
The extended coil provides routing flexibility for compatible projects requiring a greater distance between indoor and outdoor HVAC equipment.
OEM and Project Supply
Multiple sizes, insulation thicknesses, lengths, private-label branding and customized packaging are available for distributors, importers and HVAC project buyers.
DABUND Pre-Insulated Copper Pipe Factory
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC products for international distributors, contractors and project customers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber mini split line set insulation references ASTM E84, UL94, ASTM D1056 and ASTM G21.
Because the featured configuration on this page uses White PE insulation, buyers requiring project-specific compliance documentation should confirm the exact insulation material, thickness and corresponding test report for the ordered product.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where distributors and professional buyers can review pre-insulated copper tubing, mini split line sets and related HVAC products.

Frequently Asked Questions
What is a 100 ft 1/4 x 3/8 pre-insulated copper pipe used for?
It is used as refrigerant piping between compatible indoor and outdoor HVAC equipment, including mini split air conditioners, heat pumps and refrigeration systems.
How long is this pre-insulated copper pipe?
The product is 100 ft long, approximately 30.5 m.
What does 1/4 in. x 3/8 in. mean?
It refers to the outside diameters of the paired refrigerant tubes: 1/4 in. for the liquid line and 3/8 in. for the suction line.
What size mini split can use a 1/4 x 3/8 line set?
The wider DABUND product family lists 1/4 x 3/8 as a general reference for some 0.75–1.0 ton or 9,000–12,000 BTU systems. Final line sizing must follow the HVAC equipment manufacturer's exact requirements.
Can every 9,000–12,000 BTU system use a 100 ft line set?
No. Capacity alone does not determine compatibility. Confirm the required tube sizes, maximum permitted piping length, maximum elevation difference and refrigerant charging requirements for the specific equipment.
Does a 100 ft line set require additional refrigerant?
Additional refrigerant may be required depending on the equipment's factory charge and total installed line length. Follow the HVAC equipment manufacturer's charging instructions.
What copper material is used?
The source product information specifies 99.9% pure copper and references ASTM B280 / C12200.
What insulation material is shown?
The featured product configuration and series table show White PE insulation, with IXPE foam and a closed-cell inner structure referenced in the page content.
What White PE insulation thicknesses are available?
The wider product family lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thicknesses.
Is the copper tubing compatible with R410A and R32?
R410A and R32 are listed in the source product information. Final compatibility must be confirmed against the equipment manufacturer's refrigerant, tubing and operating-pressure requirements.
What is the pressure rating?
The source page lists a pressure range of 2100–7000 PSI. Because allowable pressure depends on tube diameter, wall thickness, temperature and configuration, confirm the applicable rating for the exact tubing ordered.
Can the copper pipe be installed outdoors?
The source product information describes the PE outer layer as UV resistant. Final outdoor suitability should be confirmed for the exact ordered insulation configuration and exposure conditions.
Can the 100 ft copper pipe be shortened?
The copper tubing can be cut to suit the required project length when appropriate HVAC cutting, deburring, flaring or brazing procedures are used according to the system design.
What other pre-insulated copper pipe sizes are available?
Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.
Does DABUND support OEM and ODM orders?
Yes. The source product information lists custom lengths, insulation thicknesses, logo printing, private labeling, customized packaging and bulk production support.
Is DABUND a pre-insulated copper pipe manufacturer?
Yes. The source product information identifies DABUND as a manufacturer of pre-insulated copper pipe, mini split line sets and related HVAC products.