100 ft 1/4 in. x 3/8 in. Mini Split Long Line Set
DABUND 100 ft 1/4 in. x 3/8 in. Mini Split Long Line Set provides a pre-insulated copper refrigerant piping solution for compatible ductless mini split air conditioners, heat pumps, HVAC systems and refrigeration applications requiring an extended piping route.
The paired copper tubing combines a 1/4 in. liquid line with a 3/8 in. suction line and provides a continuous 100 ft length, approximately 30.5 m.
Manufactured from 99.9% pure copper with ASTM B280 / C12200 referenced for the tubing, the line set is supplied with factory-applied White PE / IXPE insulation to help reduce thermal exchange, surface condensation and additional field insulation work.
Quick Answer: This 100 ft 1/4 x 3/8 mini split long line set combines high-purity copper tubing with White PE / IXPE insulation for compatible long-distance ductless AC, heat-pump and HVAC installations.
100 ft Mini Split Long Line Set Video
100 ft 1/4 x 3/8 Line Set Specifications
| Product Type | Pre-Insulated Mini Split Refrigerant Line Set |
| Pipe Size | 1/4 in. x 3/8 in. |
| Liquid Line | 1/4 in. / 6.35 mm |
| Suction Line | 3/8 in. / 9.52 mm |
| Length | 100 ft / approximately 30.5 m |
| Copper Material | 99.9% Pure Copper |
| Copper Specification | ASTM B280 / C12200 |
| Featured Insulation | White PE / IXPE Foam |
| Insulation Structure | UV-Resistant PE Outer Layer / IXPE Foam / Closed-Cell Inner Layer |
| Listed Temperature Range | -40°C to 120°C; confirm the rating for the selected insulation configuration |
| Listed Pressure Range | 2100–7000 PSI; actual rating depends on tube dimensions and wall thickness |
| Listed Refrigerants | R410A and R32; final suitability must follow equipment specifications |
| Applications | Compatible Mini Split, Heat Pump, HVAC and Refrigeration Systems |
100 ft Long Line Set for Extended HVAC Installations
The 100 ft continuous copper line provides additional routing flexibility for compatible installations where indoor and outdoor HVAC equipment are positioned farther apart.
Typical project layouts may include large residential properties, multi-room mini split systems, multi-story buildings and other applications requiring longer refrigerant piping routes.
A continuous refrigerant line can reduce unnecessary intermediate joints when the complete piping route remains within the HVAC equipment manufacturer's permitted piping limits.
1/4 in. Liquid Line and 3/8 in. Suction Line
The paired refrigerant tubing combines a 1/4 in. copper liquid line with a 3/8 in. copper suction return line.
Before ordering, verify that the selected mini split, heat-pump or refrigeration equipment specifically requires these exact pipe diameters.
Refrigerant piping should not be selected only by nominal BTU or tonnage because required liquid-line and suction-line sizes can vary between HVAC manufacturers and individual models.
ASTM B280 C12200 Copper Refrigerant Tubing
The copper tubing is specified as 99.9% pure copper with ASTM B280 and C12200 referenced for HVAC refrigerant piping applications.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible refrigerant piping systems.
Suitable HVAC tube-bending methods and appropriate bend radii should be used to reduce the risk of kinking, flattening or restricting refrigerant flow.
Pressure Capability for R410A and R32 Applications
The product information lists a pressure range of 2100–7000 PSI and references R410A and R32 refrigerant applications.
Allowable working pressure varies according to copper tube diameter, wall thickness, operating temperature and the exact ordered configuration. Confirm the applicable tubing specification before selecting it for a particular HVAC system.
Pre-Insulated White PE Copper Line Set
The featured configuration uses White PE insulation around the copper refrigerant tubing.
Factory-applied insulation helps reduce unwanted thermal exchange and condensation while reducing the amount of field insulation work required during installation.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Protective Plastic Cap
White PE Embossed Insulation
The White PE outer layer provides a protective surface around the insulation while supporting suitable indoor and outdoor HVAC piping applications.

Insulation Production and Structure

Insulation Pipe Production

Insulation Pipe Warehouse

Inner Layer Insulated Pipe
Three-Layer White PE / IXPE Insulation Structure
UV-Resistant PE Outer Layer
The outer layer uses PE film designed to provide protection against UV exposure and environmental wear.
IXPE Foam Middle Layer
The IXPE foam middle layer provides thermal insulation, cushioning and additional protection around the copper tubing.
Closed-Cell Inner Layer
The closed-cell inner layer helps limit moisture penetration and reduce condensation around cold refrigerant piping.
Condensation and Moisture Control
Proper insulation coverage helps reduce surface condensation and unnecessary moisture exposure along the refrigerant piping route.
Flexible Copper Tubing for HVAC Installation
The paired copper tubing is supplied in a flexible coil for routing through compatible walls, ceilings and building structures.
Appropriate HVAC bending tools and suitable bend radii should be used to reduce the risk of kinking, tube deformation or refrigerant-flow restriction.
Compatible HVAC and Refrigeration Applications
Compatible ductless mini split air conditioners
Heat-pump systems
Residential HVAC systems
Multi-room mini split installations
Compatible central air-conditioning systems requiring this pipe size
Compatible refrigeration systems
Extended refrigerant piping projects
Final compatibility should be confirmed from the equipment manufacturer's required liquid-line size, suction-line size, refrigerant type, maximum piping length, elevation limits and operating-pressure requirements.
General 9,000–12,000 BTU Capacity Reference
The wider DABUND product family lists the 1/4 in. + 3/8 in. configuration as a general reference for some 0.75–1.0 ton or 9,000–12,000 BTU mini split systems.
This is a general reference only. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact specifications.
OEM and Custom Mini Split Line Set Options
DABUND supports customized line-set production for distributors, importers, HVAC brands and project buyers.
Custom pipe-size combinations
Custom line-set lengths
Multiple insulation thicknesses
Private-label branding
Logo printing on insulation
Customized packaging
Bulk production support

Available Mini Split Line Set Sizes
| Size | Available Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: The wider product family lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths. This specific SKU is 100 ft, approximately 30.5 m, so buyers should specify the exact finished 100 ft length when ordering.
General Line Set Size and Capacity Reference
The following capacity ranges are general references from the wider DABUND product family. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact requirements.
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
Critical Checks for a 100 ft Refrigerant Run
Verify Maximum Permitted Piping Length
Confirm that the specific mini split or heat-pump system permits at least the required 100 ft refrigerant piping route before installation.
Confirm the Exact Pipe Sizes
Verify that the selected equipment specifically requires a 1/4 in. liquid line and 3/8 in. suction line.
Check Maximum Elevation Difference
For multi-story installations, confirm the maximum permitted vertical separation between indoor and outdoor equipment.
Check Additional Refrigerant Charge
A 100 ft refrigerant run may require additional refrigerant beyond the equipment's factory charge. Follow the manufacturer's charging instructions for the actual installed piping length.
Provide Proper Pipe Support
Use suitable HVAC-rated clips, straps or supports to reduce sagging, vibration and mechanical stress along the extended piping route.
Installation Guidelines
Plan the Complete Route Before Installation
Measure and plan the complete refrigerant piping route before uncoiling or cutting the copper tubing.
Avoid Sharp Bends and Kinks
Use appropriate tube-bending tools and suitable bend radii to reduce the risk of tube deformation and refrigerant-flow restriction.
Maintain Continuous Insulation Coverage
Avoid crushing, cutting or leaving unnecessary gaps in the insulation, especially around bends, supports and wall penetrations.
Keep Pipe Ends Protected
Keep copper tube ends capped or sealed during storage and installation to reduce moisture and contamination entering the refrigerant piping.
Use Correct Connection Procedures
Follow the HVAC equipment manufacturer's approved cutting, flaring, brazing and connection procedures for the selected system.
Pressure Test and Evacuate Before Startup
Follow the equipment manufacturer's pressure-testing, evacuation, refrigerant charging and commissioning procedures before system startup.
Why Choose the DABUND 100 ft Mini Split Long Line Set?
ASTM B280 Copper Tubing
The copper tubing uses high-purity material with ASTM B280 / C12200 referenced for compatible HVAC refrigerant applications.
White PE / IXPE Factory Insulation
The featured insulation combines a White PE exterior, IXPE foam middle layer and closed-cell inner structure.
Extended 100 ft Length
The long continuous coil provides routing flexibility for compatible projects requiring greater separation between indoor and outdoor HVAC equipment.
OEM and Project Supply
Multiple pipe sizes, production lengths, insulation thicknesses, private-label branding and custom packaging options are available for distributors and HVAC project buyers.
DABUND Mini Split Line Set Factory
DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC products for international distributors, contractors and project customers.

Insulation Test Documentation
The available certificate documentation references ASTM E84, UL94, ASTM D1056 and ASTM G21 for applicable Polypropylene or Black Rubber insulation configurations.
Because the featured product configuration on this page uses White PE insulation, buyers requiring compliance documentation should confirm the exact White PE material, insulation thickness and corresponding test report for the ordered configuration.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where distributors and professional buyers can review mini split line sets, insulated copper tubing and related HVAC products.

Frequently Asked Questions
What is a 100 ft mini split long line set used for?
It connects compatible indoor and outdoor mini split or heat-pump equipment where a longer refrigerant piping route is required.
How long is this mini split line set?
The product is 100 ft long, approximately 30.5 m.
What does 1/4 in. x 3/8 in. mean?
It refers to the outside diameters of the two refrigerant tubes: 1/4 in. for the liquid line and 3/8 in. for the suction line.
What size mini split can use a 1/4 x 3/8 line set?
The wider DABUND product family lists 1/4 x 3/8 as a general reference for some 0.75–1.0 ton or 9,000–12,000 BTU systems. Final pipe sizing must follow the equipment manufacturer's exact requirements.
Can every 9,000–12,000 BTU mini split use a 100 ft line set?
No. System capacity alone does not determine compatibility. Confirm the equipment manufacturer's maximum permitted piping length, required pipe diameters, maximum elevation difference and refrigerant charging requirements.
Does a 100 ft mini split line set require additional refrigerant?
Additional refrigerant may be required depending on the equipment's factory charge and total installed line length. Follow the HVAC equipment manufacturer's charging instructions.
What copper material is used?
The product information specifies 99.9% pure copper and references ASTM B280 / C12200.
What insulation material is used?
The featured configuration uses White PE insulation with an IXPE foam middle layer and a closed-cell inner insulation structure.
What White PE insulation thicknesses are available?
The wider product family lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm insulation thicknesses.
Is the line set compatible with R410A and R32?
R410A and R32 are listed in the product information. Final compatibility must be confirmed against the HVAC equipment manufacturer's refrigerant, tubing and pressure requirements.
What is the pressure rating?
The page lists a pressure range of 2100–7000 PSI. Because allowable pressure depends on tube diameter, wall thickness, temperature and configuration, confirm the applicable rating for the exact tubing ordered.
Is the line set suitable for outdoor installation?
The product information describes the PE outer layer as UV resistant. Final outdoor suitability should be confirmed for the exact insulation configuration and project exposure conditions.
Can the 100 ft copper line set be shortened?
The copper tubing can be cut to the required project length when proper HVAC cutting, deburring, flaring or brazing procedures are used according to the equipment design.
What other mini split line set sizes are available?
Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.
Does DABUND support OEM and private-label orders?
Yes. Custom lengths, insulation thicknesses, private-label branding, logo printing, custom packaging and bulk production are available for suitable orders.
Is DABUND a mini split line set manufacturer?
Yes. DABUND manufactures insulated copper pipe, mini split line sets and related HVAC products for distributors, contractors and project customers.
Can I request free samples?
The listed sample policy provides up to three free samples for qualified requests, with the buyer responsible for express freight. View Sample Information
What payment terms are available?
Listed payment options include T/T, L/C at sight and credit card.
What delivery terms are available?
Listed delivery terms include EXW, FOB, CFR and CIF.
What is the typical delivery time?
The listed typical delivery time is approximately 15–20 days, depending on order quantity and production requirements.