100 ft 1/4 in. x 3/8 in. Pre-Insulated Copper Line Set
DABUND 100 ft 1/4 in. x 3/8 in. Pre-Insulated Copper Line Set provides a continuous refrigerant piping solution for compatible mini split air conditioners, ductless heat pumps and split-system HVAC installations requiring an extended line run.
The paired copper tubing combines a 1/4 in. liquid line with a 3/8 in. suction line and provides a continuous 100 ft length, approximately 30.48 m.
Manufactured from 99.9% pure copper, the refrigerant tubing is supplied with factory-applied White PE insulation to help reduce thermal exchange, control surface condensation and simplify compatible HVAC installation.
Quick Answer: This 100 ft 1/4 x 3/8 mini split line set combines a 1/4 in. liquid line and 3/8 in. suction line with factory-applied insulation for compatible HVAC systems requiring a long refrigerant piping run.
100 ft Pre-Insulated Copper Line Set Video
100 ft 1/4 x 3/8 Copper Line Set Specifications
| Feature | Specification |
|---|
| Product Type | Pre-Insulated Copper HVAC Refrigerant Line Set |
| Line Set Size | 1/4 in. x 3/8 in. |
| Liquid Line | 1/4 in. / approximately 6.35 mm |
| Suction Line | 3/8 in. / approximately 9.52 mm |
| Length | 100 ft / approximately 30.48 m |
| Material | 99.9% Pure Copper |
| Insulation | Factory-Applied Thermal Insulation |
| Featured Insulation | White PE |
| Source Insulation Reference | 1/2 in. White PE insulation, listed up to 120°C |
| Applications | Compatible Mini Split, Ductless AC and Heat-Pump Systems |
| Listed Refrigerants | R410A, R32 and Similar Compatible HVAC Refrigerants |
| Installation | Pre-Insulated and Ready for Compatible HVAC Installation |
1/4 in. Liquid Line and 3/8 in. Suction Line
The 1/4 in. copper tube serves as the liquid refrigerant line, while the 3/8 in. copper tube serves as the suction return line in compatible mini split and HVAC refrigerant circuits.
Both tubing dimensions should be verified against the HVAC equipment manufacturer's specified liquid-line and suction-line requirements before ordering.
Refrigerant-line diameter should not be selected only by nominal BTU or tonnage because required pipe dimensions can vary between HVAC equipment models.
100 ft Length for Long-Distance HVAC Installations
The continuous 100 ft line set provides additional routing flexibility where indoor and outdoor HVAC equipment are separated by a significant distance.
It can support compatible multi-story buildings, rooftop condenser installations, larger residential projects and light commercial HVAC layouts where shorter line sets do not provide sufficient reach.
Using one continuous 100 ft coil can also reduce the need for intermediate refrigerant-line connections compared with joining several shorter sections, provided the complete installation remains within the HVAC equipment manufacturer's permitted piping limits.
99.9% Pure Copper Refrigerant Tubing
The refrigerant tubing is manufactured from 99.9% pure copper for compatible HVAC refrigerant piping applications.
Copper provides thermal conductivity, corrosion resistance and flexibility for routing between compatible indoor and outdoor HVAC equipment.
Factory-Applied White PE Insulation
The featured configuration uses White PE insulation around the copper refrigerant tubing.
Factory-applied insulation helps reduce unwanted heat gain and heat loss along the refrigerant line while helping control surface condensation on cold tubing.
Pre-insulated construction reduces additional field insulation work and provides consistent insulation coverage across the extended refrigerant piping run.
The source product introduction references 1/2 in. White PE insulation with flame-retardant performance and a temperature capability up to 120°C. Buyers requiring specific flame-resistance or test documentation should confirm the exact insulation configuration before ordering.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Protective Plastic Cap
White PE Insulated Copper Pipe
White PE insulation provides a protective thermal layer around the copper tubing to help reduce heat exchange and surface condensation during compatible HVAC operation.

Insulation Production and Structure

Insulation Pipe Production

Insulation Pipe Warehouse

Inner Layer Insulated Pipe
Compatible HVAC Applications
The 100 ft 1/4 x 3/8 line set is intended for compatible HVAC equipment requiring these exact refrigerant tube dimensions and an extended piping route.
Compatible mini split air conditioners
Ductless heat-pump systems
Split-system HVAC installations
Multi-story residential HVAC projects
Rooftop condenser installations
Light commercial cooling systems
Refrigerant Compatibility
The source product information lists R410A and R32 among the refrigerants used with compatible HVAC installations.
Final refrigerant compatibility, required tube dimensions, allowable working pressure and connection requirements must be verified against the specific HVAC equipment manufacturer's technical documentation.
Benefits of the 100 ft Pre-Insulated Line Set
Extended Installation Reach
The continuous 100 ft length provides additional routing flexibility where indoor and outdoor units cannot be positioned close together.
Reduced Intermediate Connections
A continuous copper line can reduce the number of intermediate refrigerant piping connections compared with joining several shorter tubing sections.
Condensation Control
Factory-applied insulation helps reduce condensation on cold refrigerant tubing and limits moisture exposure around walls, ceilings and structural penetrations.
Thermal Protection
White PE insulation helps reduce unwanted thermal exchange between the refrigerant tubing and surrounding environment over the extended piping run.
Reduced Field Insulation Work
Factory-applied insulation reduces additional field wrapping and provides consistent insulation coverage along the refrigerant tubing.
Important Considerations for a 100 ft Refrigerant Line
Verify Maximum Permitted Line Length
Confirm that the HVAC equipment manufacturer permits at least 100 ft of total refrigerant piping before selecting this product.
Check Maximum Elevation Difference
For multi-story or rooftop installations, verify the maximum permitted vertical separation between the indoor and outdoor HVAC equipment.
Check Additional Refrigerant Requirements
A 100 ft refrigerant piping run may require additional refrigerant depending on the HVAC equipment, factory refrigerant charge and total installed line length. Follow the equipment manufacturer's charging instructions.
Confirm the Exact Pipe Sizes
Confirm that the HVAC equipment specifically requires a 1/4 in. liquid line and 3/8 in. suction line before ordering.
Support the Long Refrigerant Run
Use suitable HVAC-rated clamps, straps or support brackets along the tubing route to reduce sagging, vibration and mechanical stress on the copper tubing and insulation.
Installation Guidelines
Plan the Complete Refrigerant Line Route
Measure the complete route between indoor and outdoor HVAC equipment before installation and plan a path that minimizes unnecessary bends and stress points.
Avoid Sharp Bends and Kinks
Use suitable bending methods and bend radii to reduce the risk of kinking the copper tubing or restricting refrigerant flow.
Protect Insulation at Wall Penetrations
Use sleeves or protective grommets where the line set passes through walls, studs or other structural openings to reduce insulation abrasion.
Maintain Insulation Integrity
Avoid cutting, crushing or excessively compressing the insulation because damaged insulation can reduce thermal and condensation-control performance.
Follow the HVAC Equipment Manufacturer's Instructions
Refrigerant piping, connection preparation, evacuation, refrigerant charging and system commissioning should follow the HVAC equipment manufacturer's installation requirements.
100 ft White PE Insulated Copper Line Set
The featured White PE configuration combines factory-insulated copper refrigerant tubing with a continuous 100 ft coil for compatible long-distance mini split and HVAC installations.

Available Pre-Insulated Copper Tubing Sizes
| Line Set Size | Available Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 m / 20 m / 25 m / 30 m / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
General Line Set Size and Capacity Reference
The following capacity ranges are general references from the wider DABUND line set family. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact piping requirements.
| Line Set Size | General Ton Reference | General BTU Reference |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000 / 12,000 BTU |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000 / 18,000 BTU |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000 / 30,000 BTU |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000 / 48,000 BTU |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000 / 72,000 BTU |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU |
For the 1/4 x 3/8 configuration, the DABUND product family lists 0.75–1.0 ton and 9,000–12,000 BTU as general references. Final compatibility must be confirmed from the HVAC equipment manufacturer's required liquid-line and suction-line dimensions.
Why Choose the DABUND 100 ft 1/4 x 3/8 Line Set?
Designed for Long Refrigerant Runs
The 100 ft continuous coil provides installation flexibility where compatible indoor and outdoor HVAC equipment are separated by a longer distance.
High-Purity Copper Construction
The line set uses 99.9% pure copper tubing for compatible HVAC refrigerant piping applications.
Factory-Insulated for Installation Efficiency
Factory-applied insulation reduces separate field insulation work and helps provide consistent thermal protection along the extended refrigerant line.
DABUND Insulated Copper Tubing Factory
DABUND has produced HVAC parts since 2008 and manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC products for distributors and project customers.

Insulation Test Documentation
The source certificate section references ASTM E84, UL94, ASTM D1056 and ASTM G21 for applicable Polypropylene or Black Rubber insulation configurations.
Because the featured product configuration on this page uses White PE insulation, buyers requiring specific compliance documentation should confirm the selected insulation material, insulation thickness and corresponding test report before ordering.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where distributors and professional buyers can review insulated copper tubing, mini split line sets and related HVAC products.

Frequently Asked Questions
What does 1/4 in. x 3/8 in. mean?
It refers to the outside diameters of the two refrigerant tubes: 1/4 in. for the liquid line and 3/8 in. for the suction return line.
How long is this copper line set?
The line set is 100 ft long, equivalent to approximately 30.48 m.
What material is the refrigerant tubing made from?
The source product information lists 99.9% pure copper tubing.
Is this copper tubing pre-insulated?
Yes. The refrigerant tubing is supplied with factory-applied thermal insulation.
What insulation material is shown?
The featured product configuration uses White PE insulation.
What insulation thickness is referenced for this product?
The source introduction specifically references 1/2 in. White PE insulation. The wider product family also lists White PE insulation options of 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm.
What temperature is listed for the White PE insulation?
The source product introduction states that the featured White PE insulation is suitable up to 120°C. Confirm the exact insulation specification for the selected production configuration before ordering.
What size HVAC system can use a 1/4 x 3/8 line set?
The DABUND product family lists 1/4 x 3/8 as a general reference for some 0.75–1.0 ton or 9,000–12,000 BTU systems. Final line-set sizing must follow the HVAC equipment manufacturer's required refrigerant pipe dimensions.
Can every mini split use a 100 ft line set?
No. Confirm the required liquid-line and suction-line sizes, maximum permitted refrigerant piping length, allowable elevation difference and charging requirements for the specific HVAC equipment.
Does a 100 ft line set require additional refrigerant?
Additional refrigerant may be required depending on the HVAC equipment and total installed refrigerant piping length. Follow the equipment manufacturer's charging instructions.
Is this line set compatible with R410A and R32?
R410A and R32 are listed among the compatible refrigerants. Final suitability should be verified against the specific HVAC equipment manufacturer's technical specifications.
Can this line set be installed outdoors?
The source product information describes the factory insulation as suitable for outdoor line runs. Confirm the exact insulation configuration and required UV or weather exposure performance before installation.
Is additional field insulation required?
Factory-applied insulation reduces additional field wrapping, although local codes, project specifications and installation conditions may require extra protection.
What other copper line set sizes are available?
Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.
What production lengths are available?
The wider product family lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths.
Is DABUND a manufacturer?
Yes. DABUND identifies itself as a manufacturer of insulated copper pipe, mini split line sets and related HVAC products.
Can DABUND provide free samples?
Yes. The listed sample policy provides up to three free samples for qualified requests, with the buyer paying the express freight. View Sample Information
What payment terms are available?
The listed payment options include T/T, L/C at sight and credit card.
What delivery terms are available?
Listed delivery terms include EXW, FOB, CFR and CIF.
Does DABUND support OEM and ODM?
Yes. OEM and ODM services, including logo customization, are available for suitable orders.
What is the typical delivery time?
The listed typical delivery time is approximately 15–20 days, depending on order quantity and production requirements.