Home Mini Split Installation Kit Mini Split Installation 10 ft 3/8" x 3/4" Mini Split Installation Kit HVAC LINE SET
10 ft 3/8" x 3/4" Mini Split Installation Kit HVAC LINE SET
10 ft 3/8" x 3/4" Mini Split Installation Kit HVAC LINE SET
10 ft 3/8" x 3/4" Mini Split Installation Kit HVAC LINE SET
10 ft 3/8" x 3/4" Mini Split Installation Kit HVAC LINE SET
10 ft 3/8" x 3/4" Mini Split Installation Kit HVAC LINE SET
10 ft 3/8" x 3/4" Mini Split Installation Kit HVAC LINE SET
10 ft 3/8" x 3/4" Mini Split Installation Kit HVAC LINE SET
10 ft 3/8" x 3/4" Mini Split Installation Kit HVAC LINE SET
10 ft 3/8" x 3/4" Mini Split Installation Kit HVAC LINE SET
10 ft 3/8" x 3/4" Mini Split Installation Kit HVAC LINE SET
10 ft 3/8" x 3/4" Mini Split Installation Kit HVAC LINE SET
10 ft 3/8" x 3/4" Mini Split Installation Kit HVAC LINE SET
1.Mini Split Installation Kit including one set air conditioner insulated copper pipe, size 3/8"+3/4" 10 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts. 
2. Both of the two copper pipe end do flaring and nuts. 
3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm. 
4. For the AC Installation kit, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m. 
5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200. 
6.Professional manufacturer of Mini Split Installation Kit, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 10M

Material

99.9% pure copper

Color

Black/White

Keywords

Mini Split Installation Kit

Application

HVAC
Inquire
Add to Basket

10 ft 3/8 in. x 3/4 in. Mini Split Installation Kit

The DABUND 10 ft 3/8 in. x 3/4 in. Mini Split Installation Kit combines a paired pre-insulated copper refrigerant line set with commonly required installation accessories for compatible ductless air conditioners, heat pumps and HVACR systems.

The copper tubing includes a 3/8 in. liquid line and a 3/4 in. suction line, each approximately 10 ft / 3.05 m long. The tubing uses C12200 DHP seamless copper designed to meet ASTM B280 requirements for air-conditioning and refrigeration field service.

Typical kit configurations can include factory-flared copper tube ends with flare nuts, Black closed-cell insulation, communication cable, approximately 3 m of condensate drain hose, a wall sleeve, wall cover and other installation accessories.

Quick Answer: This kit is intended for HVAC equipment that requires a 3/8 in. liquid line and a 3/4 in. suction line. Confirm the copper wall thickness, flare thread, cable specification, drain connection, refrigerant and permitted line length against the equipment manufacturer's installation manual before ordering.

10 ft Mini Split Installation Kit Specifications

Product TypeMini split installation kit with pre-insulated copper line set and accessories
Liquid Line Outside Diameter3/8 in. / 9.52 mm
Suction Line Outside Diameter3/4 in. / 19.05 mm
Copper Line Length10 ft / approximately 3.05 m
Copper MaterialC12200 DHP seamless copper
Copper StandardASTM B280 for air-conditioning and refrigeration field service
Tube EndsFactory-flared ends with flare nuts; confirm thread and equipment compatibility
InsulationBlack closed-cell insulation; White PE insulation also available
Typical Accessory ConfigurationCommunication cable, approximately 3 m drain hose, wall sleeve, wall cover and installation accessories
CustomizationTube sizes, wall thickness, length, insulation, cable, drain hose, fittings, accessories and packaging

What Is Included in the Mini Split Installation Kit?

3/8 in. x 3/4 in. Pre-Insulated Copper Line Set

The kit includes one 3/8 in. copper tube and one 3/4 in. copper tube, each approximately 10 ft long, for the refrigerant connection between compatible indoor and outdoor HVAC units.

Factory-Flared Ends and Flare Nuts

The copper tubes can be supplied with factory-flared ends and flare nuts. Flare dimensions, thread specification and nut configuration must match the connected equipment.

Communication Cable

Communication cable can be included for the electrical or communication connection between indoor and outdoor units.

Confirm the conductor count, wire gauge, voltage rating, approvals, cable length and equipment compatibility for the exact kit ordered.

Approximately 3 m Condensate Drain Hose

An approximately 3 m condensate drain hose can be supplied to route water from the indoor unit. Confirm the required hose diameter, connection and installation slope.

Wall Sleeve and Wall Cover

A wall sleeve and decorative cover help protect and finish the wall penetration used for refrigerant tubing, cable and the condensate drain hose.

Additional Installation Accessories

Wrapping tape, sealing material, cable ties, putty and other accessories can be added according to the required installation-kit configuration.

Key Features of the 3/8 x 3/4 Installation Kit

ASTM B280 C12200 Copper Tubing

The C12200 DHP seamless copper tubing is designed to meet ASTM B280 requirements for air-conditioning and refrigeration field service.

Short 10 ft Installation Length

The approximately 3.05 m copper line set is suitable for compatible installations where the indoor and outdoor units are positioned relatively close together.

Verify both the minimum and maximum refrigerant piping lengths permitted by the equipment manufacturer before installation.

Factory-Flared Connection Option

Factory-flared ends can reduce field preparation. Each flare should still be inspected, aligned and tightened to the torque specified by the connected HVAC equipment manufacturer.

Coordinated Accessory Supply

Copper tubing, communication cable, drainage components and wall-penetration accessories can be supplied together as one coordinated kit for distributors, HVAC brands and installation-kit suppliers.

OEM and Private-Label Packaging

Kit contents, component specifications, product labels, manuals, cartons and accessory arrangements can be customized for different brands and destination markets.

Copper Tubing, Insulation and Flared Connections

The kit uses seamless copper tubing for the refrigerant circuit. When specified by the connected equipment, the 3/8 in. tube functions as the liquid line and the 3/4 in. tube functions as the suction or gas line.

The final piping arrangement must follow the equipment manufacturer's piping diagram.

Black closed-cell insulation helps reduce unwanted heat transfer and surface condensation. Outdoor sections, insulation joints and cut ends should be sealed and protected according to the selected insulation specification and project requirements.

Factory-flared ends do not eliminate the need for inspection, torque-controlled tightening, pressure testing, leak testing and evacuation before refrigerant commissioning.

C12200 seamless copper tubing used in a mini split installation kit

C12200 Copper Tubing

black closed-cell insulation on mini split copper tubing

Black Closed-Cell Insulation

factory-flared copper tube end with nut for mini split installation

Factory-Flared Ends

Black Closed-Cell Insulation

Condensation Control

The closed-cell insulation structure helps reduce water-vapor transmission and surface condensation when joints and exposed ends are sealed correctly.

Thermal Protection

The insulation helps reduce unwanted heat transfer between the refrigerant tubing and the surrounding environment.

Installation Protection

The insulation also helps protect the soft copper tubing from normal abrasion and minor impact during packing, transportation and routing.

Available Insulation Options

Black insulation and White PE insulation configurations are available in multiple thicknesses. Confirm the exact insulation material and thickness required for the ordered kit.

Insulation Test Documentation

Applicable insulation configurations may be supplied with documentation referencing ASTM E84, UL 94, ASTM D1056 or ASTM G21. Confirm the matching report for the exact insulation material, thickness and product configuration ordered.

black closed-cell insulation for mini split copper line sets

Equipment Compatibility and Installation Requirements

A 3/8 in. liquid line paired with a 3/4 in. suction line is specified by selected mini split, heat-pump and HVAC systems.

Do not select the kit by BTU or tonnage alone. Confirm the exact tubing dimensions, copper wall thickness, refrigerant, permitted line length, vertical lift and flare requirements for the connected equipment.

The communication cable must match the equipment's electrical diagram, conductor count, wire gauge, voltage rating and required approvals.

The drain hose must match the indoor unit connection and should be routed with the required slope for condensate drainage.

Installation should include flare inspection, torque-controlled tightening, pressure testing, leak testing, evacuation and refrigerant commissioning according to the equipment instructions.

black insulated copper tubing and accessories for a mini split installation kit

Available Installation Kit Sizes and Lengths

DABUND supplies multiple copper tube combinations, installation lengths and insulation thicknesses. Kit lengths include 3 m, 4 m, 5 m, 7 m and 10 m options.

Tube Size CombinationAvailable LengthsBlack Insulation Thickness OptionsFlame-Retardant Options
1/4 + 3/83m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1 options
1/4 + 1/23m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1 options
1/4 + 5/83m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1 options
3/8 + 5/83m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1 options
3/8 + 3/43m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1 options
1/2 + 3/43m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1 options
3/8 + 7/83m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1 options

OEM Mini Split Installation Kit Manufacturer

DABUND has manufactured insulated copper tubing, mini split line sets and HVAC installation accessories since 2008.

OEM options include copper tube size and wall thickness, line-set length, insulation material and thickness, flare nuts, communication cable specification, drain hose, wall sleeve, decorative cover, wrapping materials, labels, manuals and carton artwork.

For an accurate quotation, provide the equipment model or detailed component specification, refrigerant, working pressure, flare thread, cable requirements, accessory list, packaging design, order quantity and destination port.

DABUND Factory

DABUND factory packaging copper line sets and mini split installation kits

Quality Documents and Test Reports

The applicable certificate or test report depends on the exact copper tube, insulation, cable and accessory configuration ordered.

Available documentation may reference ASTM B280 for copper tubing and ASTM E84, UL 94, ASTM D1056 or ASTM G21 for applicable insulation configurations.

Cable approvals and electrical ratings should be confirmed separately for the exact communication cable specified in the order.

quality certificate and test documentation for DABUND HVAC installation products

DABUND at HVAC Exhibitions

DABUND participates in international HVAC exhibitions where distributors, equipment brands and project buyers can inspect mini split installation kits, insulated copper line sets and related air-conditioning accessories.

DABUND displaying mini split installation kits at an HVAC exhibition

Frequently Asked Questions

What is included in the 10 ft 3/8 x 3/4 mini split installation kit?

A typical configuration can include a 10 ft 3/8 in. and 3/4 in. pre-insulated copper line set, factory-flared ends with flare nuts, communication cable, approximately 3 m of drain hose, wall sleeve, wall cover and installation accessories. Confirm the final bill of materials in the quotation.

Is a 3/8 x 3/4 line set suitable for every mini split?

No. It is suitable only for equipment that specifies a 3/8 in. liquid line and a 3/4 in. suction line. Confirm tube diameters, copper wall thickness, flare thread, refrigerant and permitted piping length before ordering.

Are the copper tubes available with factory-flared ends?

Yes. The kit can be supplied with factory-flared ends and flare nuts. Flare geometry and thread specification must match the connected indoor and outdoor units.

Does a factory-flared line set eliminate the need for leak testing?

No. Each flare should still be inspected and tightened to the equipment manufacturer's specified torque. The installed system also requires the applicable pressure testing, leak testing and evacuation procedures.

What communication cable is included?

Cable specifications are customizable. Confirm the conductor count, wire gauge, voltage rating, insulation type, approvals, cable length and terminal or connector requirements for the exact HVAC equipment.

How long is the supplied drain hose?

A typical kit configuration can include approximately 3 m of condensate drain hose. Confirm the required hose diameter and connection for the indoor unit.

Is the installation kit compatible with R410A or R32?

Compatibility depends on copper wall thickness, pressure rating, flare fittings, cleanliness, cable specification and the connected HVAC equipment requirements. State the refrigerant and required working pressure when ordering.

Can DABUND customize the accessories in the kit?

Yes. The copper line set, insulation, communication cable, drain hose, wall sleeve, cover, wrapping tape, sealing materials, connectors, labels and packaging can be customized according to buyer requirements.

Can I order private-label packaging?

Yes. DABUND supports OEM and ODM packaging including branded cartons, product labels, manuals, barcodes, tube markings and customized accessory arrangements.

What information is needed for a quotation?

Provide the equipment model or required tube sizes, copper wall thickness, line length, insulation specification, flare details, communication cable specification, drain hose size, accessory list, packaging, quantity, certification requirements and destination port.

Related Products

1. 3/8" x 7/8" x 50 ft is the out dimension in inch. 9.52mm - 22.22mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.