Home Copper Pipe Insulated Copper Tube 50 ft 1/4 x 1/2 Insulated Copper Line Set
50 ft 1/4 x 1/2 Insulated Copper Line Set
50 ft 1/4 x 1/2 Insulated Copper Line Set
50 ft 1/4 x 1/2 Insulated Copper Line Set
50 ft 1/4 x 1/2 Insulated Copper Line Set
50 ft 1/4 x 1/2 Insulated Copper Line Set
50 ft 1/4 x 1/2 Insulated Copper Line Set
50 ft 1/4 x 1/2 Insulated Copper Line Set
50 ft 1/4 x 1/2 Insulated Copper Line Set
50 ft 1/4 x 1/2 Insulated Copper Line Set
50 ft 1/4 x 1/2 Insulated Copper Line Set
50 ft 1/4 x 1/2 Insulated Copper Line Set
50 ft 1/4 x 1/2 Insulated Copper Line Set
1. 1/4" x 1/2" is the out dimension in inch. 6.35mm - 12.7mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard. 
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m. 
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃. 
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units. 
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410. 
7. Insulation we produce by ourself, can print your company name, size, meters etc.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 50M

Material

99.9% pure copper

Color

Black/White

Keywords

Insulated Copper Tube

Application

HVAC
Inquire
Add to Basket

50 ft 1/4 in. x 1/2 in. Insulated Copper Line Set

DABUND 50 ft 1/4 in. x 1/2 in. Insulated Copper Line Set provides pre-insulated refrigerant tubing for compatible mini split air conditioners, ductless heat pumps and split-system HVAC installations.

The paired refrigerant tubing combines a 1/4 in. liquid line with a 1/2 in. suction line and provides a continuous 50 ft length, approximately 15.24 m.

Manufactured from 99.9% pure copper, the tubing is supplied with factory-applied insulation to help reduce thermal exchange, control surface condensation and simplify compatible HVAC installation.

Quick Answer: This 50 ft 1/4 x 1/2 mini split line set combines a 1/4 in. liquid line and 1/2 in. suction line with factory-applied insulation for compatible residential and light commercial HVAC systems.

50 ft Insulated Copper Tube Video

50 ft 1/4 x 1/2 Copper Line Set Specifications

FeatureSpecification
Product TypePre-Insulated Copper HVAC Refrigerant Line Set
Line Set Size1/4 in. x 1/2 in.
Liquid Line1/4 in. / approximately 6.35 mm
Suction Line1/2 in. / approximately 12.70 mm
Length50 ft / approximately 15.24 m
Material99.9% Pure Copper
InsulationFactory-Applied Thermal Insulation
Featured InsulationWhite PE Configuration Shown
ApplicationsCompatible Mini Split, Ductless AC and Heat-Pump Systems
Listed RefrigerantsR410A, R32 and Similar Compatible HVAC Refrigerants
InstallationPre-Insulated and Ready for Compatible HVAC Connection

1/4 in. Liquid Line and 1/2 in. Suction Line

The 1/4 in. copper tube serves as the liquid refrigerant line, while the 1/2 in. copper tube serves as the suction return line in compatible mini split and split-system HVAC refrigerant circuits.

Both tube sizes should be verified against the HVAC equipment manufacturer's specified refrigerant piping dimensions before ordering.

Refrigerant line diameter should not be selected only by nominal BTU or tonnage because required liquid-line and suction-line sizes can vary between equipment models.

50 ft Length for Flexible HVAC Installation

The continuous 50 ft line set provides installation flexibility where indoor and outdoor HVAC equipment are separated by a moderate distance.

It can be used for compatible residential mini split systems, ductless heat pumps and light commercial HVAC installations where shorter line sets do not provide sufficient routing length.

A continuous 50 ft coil can also reduce the need for intermediate refrigerant-line connections compared with joining multiple shorter sections.

99.9% Pure Copper Refrigerant Tubing

The refrigerant tubing is manufactured from 99.9% pure copper for compatible HVAC refrigerant piping applications.

Copper provides thermal conductivity, corrosion resistance and flexibility for routing refrigerant tubing between compatible indoor and outdoor HVAC equipment.

Factory-Applied Thermal Insulation

Factory-applied insulation helps reduce unwanted heat gain and heat loss along the refrigerant tubing while helping control condensation on cold pipe surfaces.

Pre-insulated construction reduces additional field insulation work and provides more consistent coverage around the copper tubing.

The featured product images show a White PE insulated configuration. Buyers requiring a specific insulation material, thickness, flame-resistance rating or test report should confirm the selected configuration before ordering.

Copper Line Set and Insulation Video

99.9 percent pure copper HVAC refrigerant tubing

99.9% Pure Copper

white PE insulated copper HVAC refrigerant pipe

White PE Insulated Pipe

protective plastic cap for insulated copper HVAC line set

Protective Plastic Cap

White PE Insulated Copper Pipe

The featured configuration uses White PE insulation around the copper refrigerant tubing.

The insulation provides a thermal barrier that helps reduce heat exchange and surface condensation while adding protection around the copper tubing during handling and installation.

white PE embossed insulation for HVAC copper refrigerant tubing

Insulation Production and Structure

machines for HVAC thermal insulation pipe production

Insulation Pipe Production

warehouse for HVAC insulation pipe

Insulation Pipe Warehouse

inner insulation layer for HVAC refrigerant tubing

Inner Layer Insulated Pipe

Compatible HVAC Applications

The 50 ft 1/4 x 1/2 insulated copper line set is intended for compatible HVAC equipment requiring these exact refrigerant tube dimensions.

  • Compatible mini split air conditioners

  • Ductless heat-pump systems

  • Residential split HVAC installations

  • Light commercial cooling systems

  • Replacement refrigerant-line applications with matching pipe sizes

Refrigerant Compatibility

The source product information lists R410A and R32 among the commonly used refrigerants for compatible HVAC systems.

Final refrigerant compatibility, allowable pressure, required tube dimensions and connection requirements should be verified against the HVAC equipment manufacturer's technical documentation.

Benefits of the 50 ft Pre-Insulated Line Set

Stable Thermal Performance

Factory-applied insulation helps preserve refrigerant temperature along the piping run and reduces unwanted thermal exchange with the surrounding environment.

Condensation Control

Insulation helps reduce surface condensation on cold refrigerant tubing and limits moisture exposure near walls and structural penetrations.

Reduced Field Insulation Work

Factory insulation reduces additional field wrapping and provides more consistent coverage around the copper refrigerant tubing.

50 ft Installation Flexibility

The continuous 50 ft coil provides flexibility for compatible installations where indoor and outdoor HVAC units are separated by a moderate distance.

Important Considerations for a 50 ft Refrigerant Line

Verify Maximum Permitted Piping Length

Confirm that the HVAC equipment manufacturer permits at least 50 ft of total refrigerant piping before selecting this line set.

Check Maximum Elevation Difference

If the indoor and outdoor units are installed at different heights, verify the maximum permitted vertical separation specified by the equipment manufacturer.

Check Additional Refrigerant Requirements

Additional refrigerant may be required depending on the HVAC equipment, factory charge and total installed line length. Follow the equipment manufacturer's charging instructions.

Confirm the Exact Pipe Sizes

Confirm that the specific HVAC equipment requires a 1/4 in. liquid line and 1/2 in. suction line before installation.

Installation Guidelines

Plan the Refrigerant Line Route Before Installation

Measure the total distance between indoor and outdoor units before installation and plan the routing path to reduce unnecessary bends and stress points.

Avoid Sharp Bends and Kinks

Use appropriate bending methods and bend radii to reduce the risk of kinking the copper tubing or restricting refrigerant flow.

Protect Insulation at Wall Penetrations

Use wall sleeves or protective grommets where the tubing passes through walls or structural openings to reduce insulation abrasion.

Support the Refrigerant Tubing

Secure the tubing with suitable HVAC-rated straps, clips or brackets to reduce vibration, prevent sagging and maintain insulation integrity.

Follow the Equipment Manufacturer's Instructions

Refrigerant piping, connection preparation, evacuation, charging and system commissioning should follow the HVAC equipment manufacturer's installation requirements.

50 ft White PE Insulated Copper Line Set

The featured White PE configuration combines factory-insulated copper refrigerant tubing with a continuous 50 ft coil for compatible mini split and ductless HVAC installations.

50 ft 1/4 x 1/2 white PE insulated copper HVAC refrigerant line set

Available Insulated Copper Tube Sizes

Line Set SizeAvailable LengthsWhite PE InsulationListed Flame-Resistance Options
1/4 + 3/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 1/2 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 5/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 5/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 3/4 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/2 + 3/4 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 7/8 in.15 m / 20 m / 25 m / 30 m / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1

General Line Set Size and Capacity Reference

The following capacity ranges are general references from the wider DABUND insulated copper line set family. Final refrigerant-line sizing must follow the HVAC equipment manufacturer's exact piping requirements.

Line Set SizeGeneral Ton ReferenceGeneral BTU Reference
1/4 + 3/8 in.0.75–1.0 Ton9,000 / 12,000 BTU
1/4 + 1/2 in.1.5–2.0 Ton12,000 / 18,000 BTU
1/4 + 5/8 in.2.0–2.5 Ton24,000 / 30,000 BTU
3/8 + 5/8 in.3.0–4.0 Ton36,000 / 48,000 BTU
3/8 + 3/4 in.4.5–6.0 Ton54,000 / 72,000 BTU
3/8 + 7/8 in.6.0–8.0 Ton72,000–96,000 BTU

For the 1/4 x 1/2 configuration, the DABUND product family lists 1.5–2.0 ton and 12,000–18,000 BTU as general references. Final compatibility must be confirmed from the exact liquid-line and suction-line dimensions specified by the HVAC equipment manufacturer.

Why Choose the DABUND 50 ft 1/4 x 1/2 Line Set?

High-Purity Copper Construction

The product uses 99.9% pure copper tubing for compatible HVAC refrigerant piping applications.

Factory-Insulated for Installation Efficiency

Factory-applied insulation reduces field wrapping and helps provide consistent thermal protection along the refrigerant line.

Suitable for Residential and Light Commercial Projects

The 50 ft length provides routing flexibility for compatible mini split, ductless heat-pump and light commercial HVAC installations.

DABUND Insulated Copper Tube Factory

DABUND manufactures insulated copper pipe, mini split line sets, aluminum pipe and related HVAC installation products for distributors and project customers.

DABUND factory manufacturing insulated copper HVAC line sets

Insulation Test Documentation

The source certificate section references ASTM E84, UL94, ASTM D1056 and ASTM G21 for applicable Polypropylene or Black Rubber insulation configurations.

Because the featured product images on this page show White PE insulation, buyers requiring specific compliance documentation should confirm the selected insulation material, insulation thickness and corresponding test report before ordering.

DABUND HVAC line set insulation test documentation

International HVAC Exhibitions

DABUND participates in international HVAC exhibitions where distributors and professional buyers can review insulated copper tubing, mini split line sets and related HVAC installation products.

DABUND insulated copper HVAC line set at international trade show

Frequently Asked Questions

What does 1/4 in. x 1/2 in. mean?

It refers to the outside diameters of the two refrigerant tubes: 1/4 in. for the liquid line and 1/2 in. for the suction return line.

How long is this insulated copper line set?

The line set is 50 ft long, equivalent to approximately 15.24 m.

What material is the refrigerant tubing made from?

The source product information lists 99.9% pure copper tubing.

Is the copper tube pre-insulated?

Yes. The refrigerant tubing is supplied with factory-applied thermal insulation.

What insulation configuration is shown?

The featured product images show a White PE insulated configuration.

What insulation thicknesses are available?

The wider product family lists White PE insulation thicknesses of 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm.

What size HVAC system can use a 1/4 x 1/2 line set?

The DABUND product family lists 1/4 x 1/2 as a general reference for some 1.5–2.0 ton or 12,000–18,000 BTU systems. Final line-set sizing must follow the HVAC equipment manufacturer's required piping dimensions.

Can every mini split use a 50 ft line set?

No. Confirm the required liquid-line and suction-line dimensions, maximum permitted piping length, allowable elevation difference and refrigerant charging requirements for the specific equipment.

Does a 50 ft line set require additional refrigerant?

Additional refrigerant may be required depending on the HVAC equipment and total installed piping length. Follow the equipment manufacturer's charging instructions.

Is this line set compatible with R410A and R32?

R410A and R32 are listed among the compatible refrigerants. Final suitability should be verified against the HVAC equipment manufacturer's technical specifications.

Can this insulated copper line set be installed outdoors?

The source product information describes the applicable insulation jacket as UV-resistant and suitable for outdoor line runs. Confirm the exact selected insulation configuration and project exposure requirements before installation.

Is additional field insulation required?

Factory-applied insulation reduces additional field wrapping, although local codes, project specifications and installation conditions may require additional protection.

What other insulated copper tube sizes are available?

Listed combinations include 1/4 + 3/8, 1/4 + 1/2, 1/4 + 5/8, 3/8 + 5/8, 3/8 + 3/4, 1/2 + 3/4 and 3/8 + 7/8 in.

What production lengths are available?

The wider product family lists 15 m, 20 m, 25 m, 30 m and 50 m production lengths.

Is DABUND a manufacturer?

Yes. The source product information identifies DABUND as the manufacturer.

Can DABUND provide free samples?

Yes. The listed sample policy provides up to three free samples for qualified requests, with the buyer paying the express freight.    View Sample Information

What payment terms are available?

Listed payment options include T/T, L/C at sight and credit card.

What delivery terms are available?

Listed delivery terms include EXW, FOB, CFR and CIF.

Does DABUND support OEM and ODM?

Yes. OEM and ODM services, including logo customization, are available for suitable orders.

What is the typical delivery time?

The listed typical delivery time is approximately 15–20 days, depending on order quantity and production requirements.

Related Products

Please select a data source

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.