50 ft 1/2 in. x 3/4 in. Insulated Copper Pipe
The DABUND 50 ft 1/2 in. x 3/4 in. Insulated Copper Pipe is a pre-insulated HVAC refrigerant line set designed for compatible commercial air conditioning systems, heat pumps, central HVAC systems, refrigeration equipment and other projects requiring these exact copper tube sizes.
The paired line set combines a 1/2 in. refrigerant line with a 3/4 in. refrigerant line and provides a fixed 50 ft length, equal to approximately 15.24 m.
The source product information specifies 99.9% pure copper and lists White PE, Polypropylene and Rubber insulation options. White PE is the primary configuration shown in the product images and size table.
Quick Answer: This 50 ft 1/2 x 3/4 pre-insulated copper line set is intended for compatible commercial HVAC and refrigeration systems requiring these exact line sizes. The source page references larger HVAC applications, but final pipe sizing must always follow the equipment manufacturer's installation manual.
50 ft Insulated Copper Pipe Video
1/2 x 3/4 Commercial HVAC Line Set Specifications
| Parameter | Details |
|---|
| Brand | DABUND |
| Product Name | 50 ft 1/2 in. x 3/4 in. Insulated Copper Pipe |
| Product Type | Commercial HVAC Pre-Insulated Copper Line Set |
| Copper Pipe Size | 1/2 in. + 3/4 in. / 12.70 mm + 19.05 mm |
| Length | 50 ft / approximately 15.24 m |
| Copper Material | 99.9% Pure Copper |
| Insulation Options | White PE / Polypropylene / Rubber Insulation |
| Listed Temperature Range | -40°C to 120°C; confirm for exact insulation configuration |
| Source-Listed Pressure Range | 2100–7000 PSI according to specification; actual allowable pressure depends on tube dimensions, wall thickness and temperature |
| Copper Standards | ASTM B280 / C12200 according to product specification |
| Applications | Compatible Commercial HVAC / Refrigeration / Heat Pump / Mini Split / Central AC Systems |
| Customization | OEM / ODM, Custom Length, Insulation Thickness, Logo Printing and Packaging |
1/2 in. x 3/4 in. Refrigerant Line Configuration
This line set combines a 1/2 in. copper tube with a 3/4 in. copper tube for compatible HVAC and refrigeration equipment requiring this exact piping combination.
The source page describes the 1/2 in. tube as the liquid line and the 3/4 in. tube as the suction line for this product configuration.
Pipe-size requirements vary by equipment manufacturer, refrigerant circuit and model. Always verify both required tube diameters before ordering.
99.9% Pure Copper Refrigerant Tubing
The source page specifies 99.9% pure copper for the refrigerant tubing.
Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible commercial HVAC and refrigeration piping applications.
ASTM B280 and C12200
ASTM B280 and C12200 are referenced according to product specification. Buyers requiring project-specific documentation should confirm the copper tube dimensions, wall thickness and matching technical documents for the ordered configuration.
Pressure Capability for Commercial HVAC Applications
The source page lists a pressure range of approximately 2100–7000 PSI.
This should not be treated as a universal working-pressure rating for every 1/2 x 3/4 tube configuration. Actual allowable working pressure depends on copper diameter, wall thickness, operating temperature and exact product specification.
R410A is referenced among the intended modern HVAC refrigerant applications. Final refrigerant compatibility must follow the equipment manufacturer's piping and pressure requirements.
Factory-Applied HVAC Insulation
Factory-applied insulation reduces additional field wrapping work and helps provide consistent coverage around the copper refrigerant tubing.
White PE Insulation
White PE is the primary insulation configuration shown in the product imagery and wider product-family table.
Polypropylene and Rubber Options
Polypropylene and Rubber insulation configurations are also listed and can be selected according to project requirements.
Condensation Protection
Closed-cell insulation helps reduce surface condensation and moisture penetration around cold refrigerant lines when the insulation material and thickness match the installation environment.
Listed Temperature Range
The source page lists approximately -40°C to 120°C for applicable insulation configurations. Confirm the rating for the exact material ordered.
50 ft Length for Commercial HVAC Routing
The fixed 50 ft line set equals approximately 15.24 m and provides routing flexibility for compatible projects where indoor and outdoor equipment are separated by a greater distance.
A continuous refrigerant line can reduce unnecessary intermediate joints compared with joining several shorter sections, provided the complete installation remains within the equipment manufacturer's allowable piping limits.
HVAC System Capacity Selection
The source page references the 1/2 x 3/4 configuration for larger HVAC systems and lists approximately 4.5–6 ton / 54,000–72,000 BTU as a capacity reference.
Capacity should not be used as the only selection criterion. Final compatibility depends on the equipment manufacturer's specified pipe diameters, refrigerant type, design conditions and allowable piping length.
General Copper Line Set Size Reference
| Copper Line Set Size | Source Ton Range | Source BTU Range | Common Application |
|---|
| 1/4 + 3/8 in. | 0.75–1.0 Ton | 9,000–12,000 BTU | Small Mini Split AC |
| 1/4 + 1/2 in. | 1.5–2.0 Ton | 12,000–18,000 BTU | Residential Mini Split |
| 1/4 + 5/8 in. | 2.0–2.5 Ton | 24,000–30,000 BTU | Medium-Capacity Split AC |
| 3/8 + 5/8 in. | 3.0–4.0 Ton | 36,000–48,000 BTU | Large Residential / Light Commercial HVAC |
| 3/8 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU | Commercial Split AC |
| 1/2 + 3/4 in. | 4.5–6.0 Ton | 54,000–72,000 BTU | High-Capacity HVAC / Refrigeration |
| 3/8 + 7/8 in. | 6.0–8.0 Ton | 72,000–96,000 BTU | Large Ductless / Commercial HVAC |
The capacity values above reproduce the source page's general reference chart. Actual line-set dimensions must always be confirmed from the HVAC equipment manufacturer's specifications.
Product Structure and Material Display
DABUND insulated copper line sets combine high-purity copper tubing, factory-applied insulation and protected pipe ends for storage, transportation and HVAC installation.

99.9% Pure Copper

White PE Insulated Pipe

Plastic Cap Protection
White PE Insulation Detail
White PE is the main insulation configuration shown on this product page. Factory-applied insulation helps provide consistent thermal coverage around the copper tubing.

Insulation Production and Storage

Thermal Insulation Pipe Production

Insulated Pipe Warehouse

Inner Layer Insulated Pipe
OEM and Custom Commercial HVAC Line Sets
Custom copper pipe sizes
Custom line-set lengths
8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm insulation options
White PE or Rubber insulation options
Logo printing on insulation
Private-label packaging
Custom export packaging
OEM and ODM supply for distributors and project buyers
White PE Copper Line Set

Available Insulated Copper Pipe Sizes
| Size | Standard Family Lengths | White PE Insulation | Listed Flame-Resistance Options |
|---|
| 1/4 + 3/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 1/2 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/4 + 5/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 5/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 3/4 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 1/2 + 3/4 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
| 3/8 + 7/8 in. | 15 / 20 / 25 / 30 / 50 m | 8 / 9 / 10 / 13 / 19 / 25.4 mm | M1 / B1 |
Length Note: This specific SKU is 50 ft / approximately 15.24 m. The wider family table lists 15 m as the closest standard metric length, so buyers should specify the exact finished 50 ft configuration when ordering.
Commercial HVAC Applications
Commercial Air Conditioning
The product can be specified for compatible commercial buildings, offices, retail spaces, restaurants and other projects where the equipment requires a 1/2 x 3/4 line set.
Industrial Refrigeration
The source page also references refrigeration equipment, cold-room applications and industrial cooling systems when the selected copper specification matches the equipment requirements.
Heat Pumps and Central HVAC
Heat-pump and central air-conditioning applications are also referenced for compatible systems requiring these refrigerant-line dimensions.
Important Checks for a 50 ft Refrigerant Run
Confirm Exact Pipe Sizes
Verify that the selected equipment specifically requires a 1/2 in. and 3/4 in. refrigerant-line combination.
Verify Maximum Permitted Piping Length
Confirm that the HVAC or refrigeration equipment manufacturer permits the proposed 50 ft piping route.
Check Minimum Permitted Piping Length
Some equipment also specifies a minimum refrigerant piping length. Confirm both minimum and maximum limits before installation.
Check Maximum Elevation Difference
If indoor and outdoor units are installed at different elevations, verify the manufacturer's maximum permitted vertical separation.
Check Additional Refrigerant Charge
A 50 ft run may require additional refrigerant depending on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions.
Check Equivalent Piping Length
Bends, fittings and elevation changes may increase equivalent piping length beyond the physical 50 ft tube length. Follow the manufacturer's engineering limits for the complete route.
Installation Guidelines
Plan the Complete Route
Measure and plan the complete refrigerant route before uncoiling, cutting or modifying the copper tubing.
Avoid Sharp Bends and Kinks
Use suitable HVAC tube-bending tools and appropriate bend radii to reduce the risk of copper deformation or refrigerant-flow restriction.
Protect the Insulation
Avoid crushing, cutting or leaving unnecessary gaps in the insulation around bends, supports and building penetrations.
Keep Copper Ends Protected
Keep open copper tube ends capped or sealed before final connection to reduce moisture, dust and contamination entering the refrigerant circuit.
Pressure Test and Evacuate Before Startup
Refrigerant piping should be properly connected, leak-tested, evacuated, charged and commissioned according to the equipment manufacturer's instructions and applicable local requirements.
Packaging and Delivery
Standard export packaging for insulated copper pipe
Custom carton and private-label packaging available
Suitable for container loading and bulk wholesale orders
Source page lists a typical delivery time of approximately 15–20 days, subject to order quantity and customization requirements
DABUND Insulated Copper Pipe Factory
DABUND manufactures insulated copper pipes, mini split line sets, aluminum pipes and related HVAC components for international distributors, wholesalers, contractors and project buyers.

Insulation Test Documentation
The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations can meet ASTM E84, UL94, ASTM D1056 and ASTM G21 requirements according to product specification.
White PE is the primary insulation configuration shown on this page. Buyers requiring compliance documentation for White PE should confirm the exact insulation material, thickness and corresponding test report rather than assuming that Polypropylene or Black Rubber documentation applies automatically.

International HVAC Exhibitions
DABUND participates in international exhibitions where professional buyers can review insulated copper pipe, mini split line sets and related HVAC products.

Frequently Asked Questions
What is a 1/2 x 3/4 insulated copper pipe used for?
It is used as refrigerant piping in compatible HVAC, commercial air-conditioning, heat-pump and refrigeration equipment requiring 1/2 in. and 3/4 in. copper tube sizes.
How long is this copper line set?
This SKU is 50 ft long, approximately 15.24 m.
What HVAC capacity uses a 1/2 x 3/4 line set?
The current source page references approximately 4.5–6 ton / 54,000–72,000 BTU for the 1/2 x 3/4 configuration. Final line-set selection must still follow the HVAC equipment manufacturer's required pipe dimensions.
What copper material is used?
The source page specifies 99.9% pure copper and references ASTM B280 and C12200 in the technical specification.
What insulation options are available?
White PE, Polypropylene and Rubber insulation options are listed. White PE is the primary configuration shown in the product imagery.
What insulation thicknesses are available?
The source family table lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm White PE insulation thickness options.
What is the listed temperature range?
The source technical table lists approximately -40°C to 120°C. Confirm the applicable rating for the exact insulation material ordered.
What is the pressure rating?
The source page lists a 2100–7000 PSI range. Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and exact product configuration.
Can this copper line set be used with R410A?
R410A is referenced on the source page. Final compatibility depends on copper dimensions, wall thickness, allowable working pressure, piping length and equipment requirements.
Is 50 ft suitable for every commercial HVAC system?
No. Confirm the equipment manufacturer's minimum and maximum permitted piping lengths, elevation limits and additional refrigerant-charge requirements.
Does a 50 ft refrigerant run require additional refrigerant?
It may. Additional refrigerant depends on the equipment's factory charge and included piping allowance. Follow the equipment manufacturer's charging instructions.
Can this insulated copper pipe be used outdoors?
Outdoor suitability depends on the exact insulation configuration, UV resistance and environmental exposure. Confirm the specification for the material ordered.
Can DABUND customize this copper line set?
Yes. DABUND supports custom pipe sizes, lengths, insulation thickness, insulation color, logo printing, carton design and private-label packaging.
Is DABUND a manufacturer?
Yes. The source page identifies DABUND as a manufacturer of insulated copper pipe, mini split line sets, aluminum pipe and HVAC parts.
Are samples available before bulk ordering?
The source page states that free samples can be provided for evaluation, with customers generally covering express shipping costs.
What payment terms are available?
The source page lists T/T, L/C at sight and credit card among available payment methods, subject to order details.
What delivery terms are available?
EXW, FOB, CFR and CIF are listed among available international trade terms.
What is the typical delivery time?
The source page lists approximately 15–20 days as a typical delivery time, subject to order quantity, customization requirements and production scheduling.
Is professional HVAC installation recommended?
Yes. Refrigerant piping should be installed, connected, leak-tested, evacuated, charged and commissioned according to the equipment manufacturer's instructions and applicable local requirements.