Home Copper Pipe Insulated Copper Pipe 1/2" x 3/4" x 50 ft Insulated Copper Pipe – Heavy-Duty HVAC & Commercial Line Set Supplier
1/2" x 3/4" x 50 ft Insulated Copper Pipe – Heavy-Duty HVAC & Commercial Line Set Supplier
1/2" x 3/4" x 50 ft Insulated Copper Pipe – Heavy-Duty HVAC & Commercial Line Set Supplier
1/2" x 3/4" x 50 ft Insulated Copper Pipe – Heavy-Duty HVAC & Commercial Line Set Supplier
1/2" x 3/4" x 50 ft Insulated Copper Pipe – Heavy-Duty HVAC & Commercial Line Set Supplier
1/2" x 3/4" x 50 ft Insulated Copper Pipe – Heavy-Duty HVAC & Commercial Line Set Supplier
1/2" x 3/4" x 50 ft Insulated Copper Pipe – Heavy-Duty HVAC & Commercial Line Set Supplier
1/2" x 3/4" x 50 ft Insulated Copper Pipe – Heavy-Duty HVAC & Commercial Line Set Supplier
1/2" x 3/4" x 50 ft Insulated Copper Pipe – Heavy-Duty HVAC & Commercial Line Set Supplier
1/2" x 3/4" x 50 ft Insulated Copper Pipe – Heavy-Duty HVAC & Commercial Line Set Supplier
1/2" x 3/4" x 50 ft Insulated Copper Pipe – Heavy-Duty HVAC & Commercial Line Set Supplier
1/2" x 3/4" x 50 ft Insulated Copper Pipe – Heavy-Duty HVAC & Commercial Line Set Supplier
1/2" x 3/4" x 50 ft Insulated Copper Pipe – Heavy-Duty HVAC & Commercial Line Set Supplier
1. 1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric.
2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard. 
3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m. 
4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃. 
5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units. 
6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410. 
7. Insulation we produce by ourself, can print your company name, size, meters etc.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 50M

Material

99.9% pure copper

Color

Black/White

Keywords

Insulated Copper Pipe

Application

HVAC
Inquire
Add to Basket

50 ft 1/2 in. x 3/4 in. Insulated Copper Pipe

The DABUND 50 ft 1/2 in. x 3/4 in. Insulated Copper Pipe is a pre-insulated HVAC refrigerant line set designed for compatible commercial air conditioning systems, heat pumps, central HVAC systems, refrigeration equipment and other projects requiring these exact copper tube sizes.

The paired line set combines a 1/2 in. refrigerant line with a 3/4 in. refrigerant line and provides a fixed 50 ft length, equal to approximately 15.24 m.

The source product information specifies 99.9% pure copper and lists White PE, Polypropylene and Rubber insulation options. White PE is the primary configuration shown in the product images and size table.

Quick Answer: This 50 ft 1/2 x 3/4 pre-insulated copper line set is intended for compatible commercial HVAC and refrigeration systems requiring these exact line sizes. The source page references larger HVAC applications, but final pipe sizing must always follow the equipment manufacturer's installation manual.

50 ft Insulated Copper Pipe Video

1/2 x 3/4 Commercial HVAC Line Set Specifications

ParameterDetails
BrandDABUND
Product Name50 ft 1/2 in. x 3/4 in. Insulated Copper Pipe
Product TypeCommercial HVAC Pre-Insulated Copper Line Set
Copper Pipe Size1/2 in. + 3/4 in. / 12.70 mm + 19.05 mm
Length50 ft / approximately 15.24 m
Copper Material99.9% Pure Copper
Insulation OptionsWhite PE / Polypropylene / Rubber Insulation
Listed Temperature Range-40°C to 120°C; confirm for exact insulation configuration
Source-Listed Pressure Range2100–7000 PSI according to specification; actual allowable pressure depends on tube dimensions, wall thickness and temperature
Copper StandardsASTM B280 / C12200 according to product specification
ApplicationsCompatible Commercial HVAC / Refrigeration / Heat Pump / Mini Split / Central AC Systems
CustomizationOEM / ODM, Custom Length, Insulation Thickness, Logo Printing and Packaging

1/2 in. x 3/4 in. Refrigerant Line Configuration

This line set combines a 1/2 in. copper tube with a 3/4 in. copper tube for compatible HVAC and refrigeration equipment requiring this exact piping combination.

The source page describes the 1/2 in. tube as the liquid line and the 3/4 in. tube as the suction line for this product configuration.

Pipe-size requirements vary by equipment manufacturer, refrigerant circuit and model. Always verify both required tube diameters before ordering.

99.9% Pure Copper Refrigerant Tubing

The source page specifies 99.9% pure copper for the refrigerant tubing.

Copper provides thermal conductivity, corrosion resistance and installation flexibility for compatible commercial HVAC and refrigeration piping applications.

ASTM B280 and C12200

ASTM B280 and C12200 are referenced according to product specification. Buyers requiring project-specific documentation should confirm the copper tube dimensions, wall thickness and matching technical documents for the ordered configuration.

Pressure Capability for Commercial HVAC Applications

The source page lists a pressure range of approximately 2100–7000 PSI.

This should not be treated as a universal working-pressure rating for every 1/2 x 3/4 tube configuration. Actual allowable working pressure depends on copper diameter, wall thickness, operating temperature and exact product specification.

R410A is referenced among the intended modern HVAC refrigerant applications. Final refrigerant compatibility must follow the equipment manufacturer's piping and pressure requirements.

Factory-Applied HVAC Insulation

Factory-applied insulation reduces additional field wrapping work and helps provide consistent coverage around the copper refrigerant tubing.

White PE Insulation

White PE is the primary insulation configuration shown in the product imagery and wider product-family table.

Polypropylene and Rubber Options

Polypropylene and Rubber insulation configurations are also listed and can be selected according to project requirements.

Condensation Protection

Closed-cell insulation helps reduce surface condensation and moisture penetration around cold refrigerant lines when the insulation material and thickness match the installation environment.

Listed Temperature Range

The source page lists approximately -40°C to 120°C for applicable insulation configurations. Confirm the rating for the exact material ordered.

50 ft Length for Commercial HVAC Routing

The fixed 50 ft line set equals approximately 15.24 m and provides routing flexibility for compatible projects where indoor and outdoor equipment are separated by a greater distance.

A continuous refrigerant line can reduce unnecessary intermediate joints compared with joining several shorter sections, provided the complete installation remains within the equipment manufacturer's allowable piping limits.

HVAC System Capacity Selection

The source page references the 1/2 x 3/4 configuration for larger HVAC systems and lists approximately 4.5–6 ton / 54,000–72,000 BTU as a capacity reference.

Capacity should not be used as the only selection criterion. Final compatibility depends on the equipment manufacturer's specified pipe diameters, refrigerant type, design conditions and allowable piping length.

General Copper Line Set Size Reference

Copper Line Set SizeSource Ton RangeSource BTU RangeCommon Application
1/4 + 3/8 in.0.75–1.0 Ton9,000–12,000 BTUSmall Mini Split AC
1/4 + 1/2 in.1.5–2.0 Ton12,000–18,000 BTUResidential Mini Split
1/4 + 5/8 in.2.0–2.5 Ton24,000–30,000 BTUMedium-Capacity Split AC
3/8 + 5/8 in.3.0–4.0 Ton36,000–48,000 BTULarge Residential / Light Commercial HVAC
3/8 + 3/4 in.4.5–6.0 Ton54,000–72,000 BTUCommercial Split AC
1/2 + 3/4 in.4.5–6.0 Ton54,000–72,000 BTUHigh-Capacity HVAC / Refrigeration
3/8 + 7/8 in.6.0–8.0 Ton72,000–96,000 BTULarge Ductless / Commercial HVAC

The capacity values above reproduce the source page's general reference chart. Actual line-set dimensions must always be confirmed from the HVAC equipment manufacturer's specifications.

Product Structure and Material Display

DABUND insulated copper line sets combine high-purity copper tubing, factory-applied insulation and protected pipe ends for storage, transportation and HVAC installation.

99.9 percent pure copper for commercial HVAC line set

99.9% Pure Copper

White PE insulated copper pipe for commercial HVAC

White PE Insulated Pipe

plastic cap protection for AC copper line set

Plastic Cap Protection

White PE Insulation Detail

White PE is the main insulation configuration shown on this product page. Factory-applied insulation helps provide consistent thermal coverage around the copper tubing.

White PE embossed insulated copper pipe

Insulation Production and Storage

thermal insulation pipe production equipment

Thermal Insulation Pipe Production

warehouse for insulated copper pipes

Insulated Pipe Warehouse

inner layer insulated copper pipe

Inner Layer Insulated Pipe

OEM and Custom Commercial HVAC Line Sets

  • Custom copper pipe sizes

  • Custom line-set lengths

  • 8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25.4 mm insulation options

  • White PE or Rubber insulation options

  • Logo printing on insulation

  • Private-label packaging

  • Custom export packaging

  • OEM and ODM supply for distributors and project buyers

White PE Copper Line Set

White PE copper line set for commercial HVAC systems

Available Insulated Copper Pipe Sizes

SizeStandard Family LengthsWhite PE InsulationListed Flame-Resistance Options
1/4 + 3/8 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 1/2 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/4 + 5/8 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 5/8 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 3/4 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
1/2 + 3/4 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1
3/8 + 7/8 in.15 / 20 / 25 / 30 / 50 m8 / 9 / 10 / 13 / 19 / 25.4 mmM1 / B1

Length Note: This specific SKU is 50 ft / approximately 15.24 m. The wider family table lists 15 m as the closest standard metric length, so buyers should specify the exact finished 50 ft configuration when ordering.

Commercial HVAC Applications

Commercial Air Conditioning

The product can be specified for compatible commercial buildings, offices, retail spaces, restaurants and other projects where the equipment requires a 1/2 x 3/4 line set.

Industrial Refrigeration

The source page also references refrigeration equipment, cold-room applications and industrial cooling systems when the selected copper specification matches the equipment requirements.

Heat Pumps and Central HVAC

Heat-pump and central air-conditioning applications are also referenced for compatible systems requiring these refrigerant-line dimensions.

Important Checks for a 50 ft Refrigerant Run

Confirm Exact Pipe Sizes

Verify that the selected equipment specifically requires a 1/2 in. and 3/4 in. refrigerant-line combination.

Verify Maximum Permitted Piping Length

Confirm that the HVAC or refrigeration equipment manufacturer permits the proposed 50 ft piping route.

Check Minimum Permitted Piping Length

Some equipment also specifies a minimum refrigerant piping length. Confirm both minimum and maximum limits before installation.

Check Maximum Elevation Difference

If indoor and outdoor units are installed at different elevations, verify the manufacturer's maximum permitted vertical separation.

Check Additional Refrigerant Charge

A 50 ft run may require additional refrigerant depending on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions.

Check Equivalent Piping Length

Bends, fittings and elevation changes may increase equivalent piping length beyond the physical 50 ft tube length. Follow the manufacturer's engineering limits for the complete route.

Installation Guidelines

Plan the Complete Route

Measure and plan the complete refrigerant route before uncoiling, cutting or modifying the copper tubing.

Avoid Sharp Bends and Kinks

Use suitable HVAC tube-bending tools and appropriate bend radii to reduce the risk of copper deformation or refrigerant-flow restriction.

Protect the Insulation

Avoid crushing, cutting or leaving unnecessary gaps in the insulation around bends, supports and building penetrations.

Keep Copper Ends Protected

Keep open copper tube ends capped or sealed before final connection to reduce moisture, dust and contamination entering the refrigerant circuit.

Pressure Test and Evacuate Before Startup

Refrigerant piping should be properly connected, leak-tested, evacuated, charged and commissioned according to the equipment manufacturer's instructions and applicable local requirements.

Packaging and Delivery

  • Standard export packaging for insulated copper pipe

  • Custom carton and private-label packaging available

  • Suitable for container loading and bulk wholesale orders

  • Source page lists a typical delivery time of approximately 15–20 days, subject to order quantity and customization requirements

DABUND Insulated Copper Pipe Factory

DABUND manufactures insulated copper pipes, mini split line sets, aluminum pipes and related HVAC components for international distributors, wholesalers, contractors and project buyers.

DABUND factory manufacturing commercial HVAC copper line sets

Insulation Test Documentation

The source certificate section states that applicable Polypropylene or Black Rubber insulation configurations can meet ASTM E84, UL94, ASTM D1056 and ASTM G21 requirements according to product specification.

White PE is the primary insulation configuration shown on this page. Buyers requiring compliance documentation for White PE should confirm the exact insulation material, thickness and corresponding test report rather than assuming that Polypropylene or Black Rubber documentation applies automatically.

SGS certificate for DABUND insulated copper line set

International HVAC Exhibitions

DABUND participates in international exhibitions where professional buyers can review insulated copper pipe, mini split line sets and related HVAC products.

DABUND commercial HVAC products at international exhibition

Frequently Asked Questions

What is a 1/2 x 3/4 insulated copper pipe used for?

It is used as refrigerant piping in compatible HVAC, commercial air-conditioning, heat-pump and refrigeration equipment requiring 1/2 in. and 3/4 in. copper tube sizes.

How long is this copper line set?

This SKU is 50 ft long, approximately 15.24 m.

What HVAC capacity uses a 1/2 x 3/4 line set?

The current source page references approximately 4.5–6 ton / 54,000–72,000 BTU for the 1/2 x 3/4 configuration. Final line-set selection must still follow the HVAC equipment manufacturer's required pipe dimensions.

What copper material is used?

The source page specifies 99.9% pure copper and references ASTM B280 and C12200 in the technical specification.

What insulation options are available?

White PE, Polypropylene and Rubber insulation options are listed. White PE is the primary configuration shown in the product imagery.

What insulation thicknesses are available?

The source family table lists 8 mm, 9 mm, 10 mm, 13 mm, 19 mm and 25.4 mm White PE insulation thickness options.

What is the listed temperature range?

The source technical table lists approximately -40°C to 120°C. Confirm the applicable rating for the exact insulation material ordered.

What is the pressure rating?

The source page lists a 2100–7000 PSI range. Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and exact product configuration.

Can this copper line set be used with R410A?

R410A is referenced on the source page. Final compatibility depends on copper dimensions, wall thickness, allowable working pressure, piping length and equipment requirements.

Is 50 ft suitable for every commercial HVAC system?

No. Confirm the equipment manufacturer's minimum and maximum permitted piping lengths, elevation limits and additional refrigerant-charge requirements.

Does a 50 ft refrigerant run require additional refrigerant?

It may. Additional refrigerant depends on the equipment's factory charge and included piping allowance. Follow the equipment manufacturer's charging instructions.

Can this insulated copper pipe be used outdoors?

Outdoor suitability depends on the exact insulation configuration, UV resistance and environmental exposure. Confirm the specification for the material ordered.

Can DABUND customize this copper line set?

Yes. DABUND supports custom pipe sizes, lengths, insulation thickness, insulation color, logo printing, carton design and private-label packaging.

Is DABUND a manufacturer?

Yes. The source page identifies DABUND as a manufacturer of insulated copper pipe, mini split line sets, aluminum pipe and HVAC parts.

Are samples available before bulk ordering?

The source page states that free samples can be provided for evaluation, with customers generally covering express shipping costs.

What payment terms are available?

The source page lists T/T, L/C at sight and credit card among available payment methods, subject to order details.

What delivery terms are available?

EXW, FOB, CFR and CIF are listed among available international trade terms.

What is the typical delivery time?

The source page lists approximately 15–20 days as a typical delivery time, subject to order quantity, customization requirements and production scheduling.

Is professional HVAC installation recommended?

Yes. Refrigerant piping should be installed, connected, leak-tested, evacuated, charged and commissioned according to the equipment manufacturer's instructions and applicable local requirements.

Related Products

1.1/2" x 3/4" is the out dimension in inch. 12.7mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1. 3/8" x 3/4" is the out dimension in inch. 9.52mm - 19.05mm is the out dimension in metric. 2. 99.9% Pure copper pipe meets ASTM B280 and C12200 standard.  3. AC Copper Size what we can do have following 1/4" 3/8" 1/2" 5/8" 3/4" 7/8" 1 1/8", length can do 15m 20m 25m 30m 50m.  4. Insulation is made of 1/2" Polypropylene & UV Resistant, meets ASTM E 84, UL94, ASTM D1056 and ASTM G 21. Working temperature from -40℃ to 120℃.  5. Works for every Air Conditioning & Refrigeration Application including Ductless mini-split, heat pump and Centralized Air Ducted Units.  6. Pressure Rating: 2100 to 7000 PSI, much more than required 700 PSI for R410.  7. Insulation we produce by ourself, can print your company name, size, meters etc.
1.Mini Split Installation Kit including one set air conditioner insulated copper pipe, size 1/4"+5/8" 30 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts.  2. Both of the two copper pipe end do flaring and nuts.  3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm.  4. For the AC Installation kit, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m.  5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200.  6.Professional manufacturer of Mini Split Installation Kit, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
1.Mini Split Installation Kit including one set air conditioner insulated copper pipe, size 1/4"+5/8" 25 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts.  2. Both of the two copper pipe end do flaring and nuts.  3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm.  4. For the AC Installation kit, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m.  5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200.  6.Professional manufacturer of Mini Split Installation Kit, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.