50 ft 3/8 in. x 7/8 in. Insulated Copper Tubing
The DABUND 50 ft 3/8 in. x 7/8 in. Insulated Copper Tubing is a pre-insulated HVAC refrigerant line set for compatible air-conditioning systems, ductless mini splits, heat pumps, centralized air-conditioning units and refrigeration applications.
This paired line set combines 3/8 in. and 7/8 in. seamless copper tubing with factory-applied White PE insulation for thermal coverage, condensation control and protection during HVAC installation.
The copper tubing uses 99.9% pure copper and is specified to ASTM B280 using C12200 DHP copper.
Quick Answer: The 3/8 x 7/8 line-set family is commonly used with compatible 6.0–8.0 ton / 72,000–96,000 BTU ductless HVAC systems. Final tube size, piping length, elevation difference and refrigerant-charge requirements must follow the HVAC equipment manufacturer's installation manual.
50 ft Insulated Copper Tubing Video
Pre-Insulated Copper Tubing for HVAC Refrigerant Lines
Pre-insulated copper tubing combines paired copper refrigerant lines with factory-applied insulation for compatible indoor-to-outdoor HVAC connections.
The 50 ft / approximately 15.24 m coil provides a continuous refrigerant piping length for projects where the equipment permits the required route.
Factory-applied insulation provides consistent coverage around the copper tubing and helps reduce unwanted heat transfer and surface condensation.
Key Features
50 ft / approx. 15.24 m pre-insulated copper line set
3/8 in. + 7/8 in. copper tubing
Metric size: 9.52 mm x 22.22 mm
99.9% pure copper tubing
ASTM B280 / C12200 DHP copper specification
1/2 in. White PE insulation
High-density closed-cell polyethylene foam
Temperature range from -40°C to 120°C
UV-resistant outer insulation structure
Suitable for compatible mini split, heat-pump and ducted HVAC systems
Suitable for compatible refrigeration applications
OEM company name, pipe size and length printing available
Specifications and Quality Standards
| Specification | Detail |
|---|
| Product Name | 50 ft 3/8 in. x 7/8 in. Insulated Copper Tubing |
| Length | 50 ft / approx. 15.24 m |
| Line Size | 3/8 in. x 7/8 in. |
| Metric Size | 9.52 mm x 22.22 mm |
| Copper Material | 99.9% pure copper |
| Copper Standard | ASTM B280 and C12200 DHP |
| Insulation | 1/2 in. White PE insulation / high-density closed-cell polyethylene foam |
| Temperature Range | -40°C to 120°C |
| Pressure Rating | 2100 PSI to 7000 PSI |
| Application | HVAC, mini split, heat pump, ducted AC and refrigeration systems |
Pressure Note: The 2100–7000 PSI range applies across available copper configurations. Actual allowable working pressure depends on tube diameter, copper wall thickness, operating temperature and the exact ordered specification.
3/8 in. x 7/8 in. Refrigerant Line Size
3/8 in. Copper Line
The 3/8 in. copper tube is used according to the refrigerant piping design of the compatible HVAC equipment.
7/8 in. Copper Line
The 7/8 in. copper tube is the larger refrigerant line in this paired configuration.
Confirm the function of both refrigerant tubes and the required outside diameters from the HVAC equipment manufacturer's piping diagram before ordering.
Typical AC Capacity for 3/8 x 7/8 Line Sets
The 3/8 in. + 7/8 in. line-set family is commonly used with some 6.0–8.0 ton ductless mini split and commercial HVAC systems.
A typical capacity range is approximately 72,000–96,000 BTU.
HVAC capacity alone should not be used to select refrigerant tubing. The equipment manufacturer's required copper tube sizes always take priority.
99.9% Pure Copper Tubing
The tubing uses 99.9% pure copper for compatible HVAC and refrigeration piping applications.
ASTM B280 and C12200 DHP
The copper tubing is specified to ASTM B280 using C12200 DHP copper.
Copper Pressure Range
Available copper configurations are specified within a 2100–7000 PSI range.
Actual allowable working pressure depends on copper tube diameter, wall thickness, operating temperature and the exact tubing specification selected.
Confirm the applicable copper specification and allowable pressure against the HVAC equipment requirements before installation.
Factory-Applied White PE Insulation
This product uses 1/2 in. White PE insulation with a high-density closed-cell polyethylene foam structure.
Thermal Protection
The insulation helps reduce unwanted heat transfer between the copper refrigerant tubing and surrounding air.
Condensation Control
The closed-cell structure helps reduce surface condensation and moisture around cold refrigerant tubing.
Working Temperature Range
The insulation configuration is specified for a working temperature range from approximately -40°C to 120°C.
UV-Resistant Outer Protection
The outer PE layer provides UV-resistant protection for compatible indoor-to-outdoor HVAC line routes.
Copper Line Set and Insulation Video

99.9% Pure Copper

White PE Insulated Pipe

Plastic Cap Protection
Three-Layer Insulation Structure
Outer Layer: UV-Resistant PE Film
The outer layer uses UV-resistant PE film with an embossed surface to protect the insulation from sunlight, weather exposure and installation abrasion.
Middle Layer: IXPE Foam
The middle layer uses dense-cell IXPE foam for thermal insulation, impact absorption and water resistance.
Inner Layer: Closed-Cell Insulation
The inner closed-cell structure provides thermal coverage and helps reduce moisture penetration around the copper refrigerant tubing.

Insulation Production and Storage

Thermal Insulation Pipe Production

Insulation Pipe Warehouse

Inner Layer Insulated Pipe
HVACR Applications
Ductless mini split air conditioners
Heat-pump systems
Centralized air ducted units
Commercial split AC systems
Compatible refrigeration equipment
Replacement refrigerant-line projects
Retrofit HVAC installations
R410A and R32 can be used when the selected tubing dimensions, copper specification, allowable pressure and HVAC equipment requirements match.
Important Checks for a 50 ft Refrigerant Run
Confirm the Required 3/8 x 7/8 Tube Sizes
Verify that the selected HVAC equipment specifically requires 3/8 in. and 7/8 in. copper refrigerant tubing.
Confirm Each Tube's Function
Confirm the liquid, suction or other refrigerant-line function of each tube from the HVAC equipment manufacturer's piping diagram.
Verify Maximum Piping Length
A physical 50 ft coil does not mean every compatible HVAC system permits a 50 ft refrigerant run. Check the equipment manufacturer's maximum piping length.
Check Minimum Piping Length
Some HVAC equipment also specifies a minimum refrigerant piping length. Confirm this requirement where applicable.
Check Maximum Elevation Difference
Verify the permitted vertical separation between indoor and outdoor HVAC equipment.
Check Refrigerant Charge Requirements
Confirm whether the equipment's factory refrigerant charge covers the installed piping length or whether additional refrigerant is required.
Check Equivalent Piping Length
Bends, fittings and elevation changes can increase equivalent piping length. Follow the equipment manufacturer's equivalent-length requirements where applicable.
Installation Guidelines
Measure the complete refrigerant-line route before installation.
Confirm the required 3/8 in. and 7/8 in. tube sizes.
Confirm each refrigerant tube's function from the equipment piping diagram.
Use suitable HVAC tube-cutting and bending tools.
Avoid sharp bends, flattening or kinking the copper tubing.
Maintain continuous insulation coverage along the complete line run.
Protect the insulation at wall and ceiling penetrations.
Support the tubing with suitable HVAC-rated clips, straps or brackets.
Keep open copper ends protected from dirt, moisture and contamination.
Prepare refrigerant connections according to the HVAC equipment manufacturer's requirements.
Pressure-test and leak-test the completed refrigerant circuit.
Evacuate, charge and commission the system according to the equipment manufacturer's instructions.
B2B Supply for HVACR Wholesalers
DABUND supplies insulated copper tubing for HVACR wholesalers, contractors, distributors, importers and private-label brands.
OEM marking, custom insulation thickness, private-label packaging and bulk supply are available for qualified B2B orders.

Insulated Copper Tubing Size Options
| Size | Length | Insulation White PE | Flame Resistant |
| 1/4 + 3/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/4 + 1/2 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/4 + 5/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 5/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 3/4 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 1/2 + 3/4 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
| 3/8 + 7/8 | 15m / 20m / 25m / 30m / 50m | 8mm / 9mm / 10mm / 13mm / 19mm / 25.4mm | M1 / B1 |
Length Note: This SKU is supplied as a 50 ft / approximately 15.24 m line set. The table above shows additional metric lengths available across the wider insulated copper tubing range.
Flame-resistance grade and supporting test documentation should be confirmed for the exact insulation material and thickness required for the order.
Recommended Applications by AC Capacity
| Line Set Size | Common AC Capacity | Typical BTU Range | Typical Application |
| 1/4 + 3/8 | 0.75 ton - 1.0 ton | 9,000 BTU - 12,000 BTU | Small mini split air conditioner |
| 1/4 + 1/2 | 1.5 ton - 2.0 ton | 12,000 BTU - 18,000 BTU | Residential mini split system |
| 1/4 + 5/8 | 2.0 ton - 2.5 ton | 24,000 BTU - 30,000 BTU | Split air conditioner system |
| 3/8 + 5/8 | 3.0 ton - 4.0 ton | 36,000 BTU - 48,000 BTU | Ductless mini split and heat pump |
| 3/8 + 3/4 | 4.5 ton - 6.0 ton | 54,000 BTU - 72,000 BTU | Larger split AC installation |
| 3/8 + 7/8 | 6.0 ton - 8.0 ton | 72,000 BTU - 96,000 BTU | Commercial ductless HVAC systems |
These capacity values provide general size-selection guidance. Final refrigerant-line selection must follow the HVAC equipment manufacturer's exact tubing requirements.
OEM and Custom Insulated Copper Tubing
Multiple copper tube combinations
Multiple metric coil lengths
Custom finished lengths
Multiple insulation thickness options
OEM company-name printing
Pipe-size and length markings
Private-label branding
Customized packaging
Bulk supply for HVACR distributors and importers
DABUND Factory
DABUND manufactures insulated copper tubing, mini split line sets, aluminum pipes and related HVAC products for contractors, wholesalers, distributors and private-label customers.

Insulation Test Documentation
Applicable Polypropylene or Black Rubber insulation configurations can be supplied with UV-resistant options and test documentation referencing ASTM E84, UL94, ASTM D1056 and ASTM G21.
White PE is the insulation configuration for this 50 ft 3/8 x 7/8 product. Buyers requiring specific fire, smoke, UV or other compliance documentation should confirm the matching report for the exact insulation material and thickness ordered.

International HVAC Exhibitions
DABUND participates in international HVAC exhibitions where buyers can review insulated copper tubing, mini split line sets and related HVAC products.

Frequently Asked Questions
What is 50 ft 3/8 x 7/8 insulated copper tubing used for?
It is used as a pre-insulated refrigerant line set for compatible ductless mini split systems, heat pumps, centralized air-conditioning units, commercial HVAC systems and refrigeration applications.
What does 3/8 x 7/8 mean?
It refers to the outside diameters of the two copper refrigerant tubes. The metric sizes are approximately 9.52 mm and 22.22 mm.
What AC capacity commonly uses a 3/8 x 7/8 line set?
The 3/8 x 7/8 line-set family is commonly used with some 6.0–8.0 ton or 72,000–96,000 BTU ductless HVAC systems. Final sizing must follow the equipment manufacturer's requirements.
How long is this insulated copper line set?
This SKU is 50 ft long, approximately 15.24 m.
What copper material is used?
The tubing uses 99.9% pure copper.
Does this copper tubing meet ASTM B280?
Yes. The copper tubing is specified to ASTM B280 using C12200 DHP copper.
What insulation is used?
This product uses 1/2 in. White PE insulation with high-density closed-cell polyethylene foam.
What is the insulation temperature range?
The insulation configuration is specified for approximately -40°C to 120°C.
What does the 2100–7000 PSI range mean?
It is the range across available copper configurations. Actual allowable working pressure depends on tube diameter, copper wall thickness, operating temperature and the exact ordered specification.
Can this tubing be used with R410A and R32?
Yes, when the HVAC equipment requires the selected tubing dimensions and the copper specification and allowable pressure match the system requirements.
Is this insulated copper tubing suitable for outdoor use?
The UV-resistant PE outer layer supports compatible indoor-to-outdoor HVAC line routes. A suitable line set cover can provide additional protection for extended outdoor exposure.
Is 50 ft suitable for every 72K–96K HVAC system?
No. Confirm the equipment manufacturer's minimum and maximum piping lengths, maximum elevation difference and refrigerant-charge requirements.
Does a 50 ft refrigerant run require additional refrigerant?
It may. Additional refrigerant depends on the equipment's factory charge and included piping allowance. Follow the manufacturer's charging instructions.
Can DABUND provide other sizes and lengths?
Yes. DABUND provides multiple insulated copper tubing size combinations, metric coil lengths and insulation thickness options for B2B orders.
Can the product be customized?
Yes. Custom lengths, insulation thicknesses, company-name printing, pipe-size markings and private-label packaging are available for OEM and ODM orders.
Is DABUND a manufacturer?
DABUND manufactures insulated copper tubing, mini split line sets, aluminum pipes and related HVAC products.
Are free samples available?
Up to 3 free samples are available for qualified customers. Express shipping costs may need to be covered by the buyer. Sample requests can be submitted through the DABUND free sample page.
What payment terms are available?
Payment terms include T/T, L/C at sight, credit card and other agreed methods depending on order details.
What delivery terms are available?
DABUND can offer EXW, FOB, CFR and CIF for international orders.
What is the typical delivery time?
Normal delivery time is usually 15–20 days, subject to order requirements and factory scheduling.