About Us          Certificate          Blog          Contact Us          Free Sample
Language
Home AC Accessories Liquid Tight Fittings Non-metallic Liquid-Tight Conduit
Non-metallic Liquid-Tight Conduit
Non-metallic Liquid-Tight Conduit
Non-metallic Liquid-Tight Conduit
Non-metallic Liquid-Tight Conduit
Non-metallic Liquid-Tight Conduit
Non-metallic Liquid-Tight Conduit
Non-metallic Liquid-Tight Conduit
Non-metallic Liquid-Tight Conduit
Non-metallic Liquid-Tight Conduit
Non-metallic Liquid-Tight Conduit
Non-metallic Liquid-Tight Conduit
Non-metallic Liquid-Tight Conduit
  • PVC、Plastic、Nylon

  • 4inch/6inch

Application

Electric Cable Wire Protection
Inquire
Add to Basket

Non-Metallic Liquid-Tight Conduit

DABUND Non-Metallic Liquid-Tight Conduit is designed to protect electrical cable and wiring in HVAC, outdoor equipment and other applications where flexible routing and protection from moisture, oil and environmental exposure are required.

The conduit is made from thermoplastic PVC/PA materials according to the current product information. It features a smooth inner surface for cable routing and a corrugated outer surface for flexibility.

A reinforcing member is embedded in the conduit wall to provide additional structural support and crush resistance while maintaining the flexibility required for equipment connections and short wiring runs.

Quick Answer: This non-metallic liquid-tight conduit is a flexible electrical cable protection solution with a reinforced thermoplastic construction, smooth inner wall and corrugated outer surface. It is intended to be used with compatible liquid-tight fittings to complete the wiring connection.

Non-Metallic Liquid-Tight Conduit Specifications

Product TypeNon-Metallic Liquid-Tight Conduit
MaterialThermoplastic PVC/PA according to current product information
Inner SurfaceSmooth
Outer SurfaceCorrugated / wave surface
ReinforcementReinforcing member embedded in the conduit wall
Listed ResistanceUV, aging and oil resistance according to current product information
Material RequirementCurrent product information states compliance with RoHS material requirements
Main ApplicationElectrical cable and wire protection
ConnectionDesigned for use with compatible liquid-tight fittings

Reinforced Non-Metallic Conduit Construction

The conduit combines a flexible thermoplastic body with an embedded reinforcing member inside the conduit wall.

This construction provides mechanical support while allowing the conduit to follow equipment connections and wiring routes where rigid conduit may be less convenient.

The smooth inner surface helps cables pass through the conduit, while the corrugated outer profile provides flexibility for routing around equipment and installation obstacles.

Liquid-Tight Protection with Compatible Fittings

The conduit is intended to work together with compatible liquid-tight fittings as part of the electrical wiring system.

The current product information states that improved water protection for the complete wiring system is achieved when the conduit is correctly connected with the appropriate liquid-tight fitting.

Actual environmental protection depends on the conduit, fitting, enclosure, installation method and the requirements of the electrical system. Buyers should confirm the required fitting type and applicable electrical code before installation.

Nylon Liquid-Tight Connectors

DABUND also supplies liquid-tight connectors for use with compatible non-metallic conduit.

According to the current product information, the connectors are made from nylon and are designed for resistance to salt water, weak acids, alcohol, oil, grease and common solvents.

The conduit size, connector size, enclosure entry and thread configuration should be confirmed before ordering to ensure that the components match the intended wiring system.

Why Use Non-Metallic Liquid-Tight Conduit?

Flexible Wiring Protection

Flexible conduit can simplify wiring routes around HVAC equipment, motors and other installations where rigid raceway routing may be difficult.

Smooth Interior for Cable Routing

The smooth inner surface helps reduce obstruction when electrical conductors or cables are routed through the conduit.

Reinforced Wall Construction

The embedded reinforcing member provides additional support and helps improve resistance to crushing during normal installation and service conditions.

Lightweight Non-Metallic Design

The non-metallic thermoplastic construction provides a lightweight conduit option for compatible electrical wiring applications.

Applications

Non-metallic liquid-tight conduit can be considered for compatible electrical wiring and equipment connections in applications including:

  • Air-conditioning outdoor unit connections

  • Ductless mini split systems

  • Heat-pump equipment

  • Motors and control equipment

  • Outdoor lighting systems

  • Pool and spa equipment where permitted by applicable electrical requirements

  • Solar equipment wiring

  • Generator equipment

  • Short-run exterior electrical connections

  • General electrical cable and wire protection

The current product information also references use with some 9,000–12,000 BTU mini split installations. Conduit selection, however, should be based on the electrical wiring requirements, cable size, conduit size, fittings and applicable electrical code rather than BTU capacity alone.

How to Select Non-Metallic Liquid-Tight Conduit

Confirm the Required Conduit Size

Determine the conduit size required for the conductors or cable being installed. Consider conductor quantity, cable dimensions and the applicable electrical installation requirements.

Confirm the Matching Connector Size

The liquid-tight fitting must match the conduit and the equipment enclosure or junction box connection.

Check the Installation Environment

Confirm whether the conduit will be installed indoors, outdoors or in an area exposed to moisture, oil, sunlight or other environmental conditions.

Check Flexibility and Routing Requirements

Plan the conduit route and allow suitable space for bends and equipment movement without excessively bending, crushing or twisting the conduit.

Confirm Applicable Electrical Requirements

Buyers and installers should confirm the applicable electrical code, project specification and required product documentation before selecting the conduit for a particular installation.

How to Install Liquid-Tight Conduit

Step 1: Plan the Wiring Route

Determine the route between the electrical enclosure and the connected equipment before cutting or installing the conduit.

Step 2: Select the Correct Conduit and Fittings

Confirm that the conduit, fittings and enclosure entries are compatible in size and configuration.

Step 3: Cut the Conduit Cleanly

Prepare a clean conduit end according to the fitting installation method and remove material that could interfere with cable routing or fitting engagement.

Step 4: Route the Electrical Cable

Route the required conductors through the conduit while avoiding excessive pulling force, sharp bends or conduit damage.

Step 5: Install the Liquid-Tight Fittings

Assemble the compatible fittings according to the fitting manufacturer's installation method and ensure that the conduit is properly seated.

Step 6: Inspect the Completed Connection

Check the conduit routing, fitting engagement and enclosure connections before the electrical system is placed into service.

Information to Confirm Before Ordering

Distributors, wholesalers, contractors and equipment manufacturers should confirm the following information before ordering:

  • Required conduit size

  • Required conduit length

  • Cable or conductor configuration

  • Required liquid-tight connector size

  • Straight or angled connector requirements

  • Equipment enclosure or knockout connection

  • Indoor or outdoor installation environment

  • Required standards or third-party documentation

  • Order quantity

  • Packaging requirements

  • OEM or private-label requirements

Non-Metallic Conduit for HVAC Installations

HVAC outdoor units, mini split systems and heat pumps frequently require a protected electrical connection between equipment and the disconnect, junction box or other electrical enclosure.

Flexible non-metallic conduit can simplify short equipment connections where the selected conduit and fittings meet the electrical and environmental requirements of the installation.

Conduit selection should be based on electrical requirements rather than air-conditioning capacity alone.

DABUND HVAC Electrical Accessories

DABUND supplies non-metallic liquid-tight conduit, liquid-tight connectors and related HVAC installation accessories for distributors, wholesalers, contractors and professional buyers.

Buyers requiring a specific conduit construction, fitting configuration or project standard should confirm the exact technical requirements before placing an order.

Frequently Asked Questions

What is non-metallic liquid-tight conduit used for?

It is used to route and protect electrical cables and conductors in compatible equipment connections, including HVAC units, heat pumps, motors, outdoor lighting, solar equipment and other applications requiring flexible wiring protection.

What material is the conduit made from?

The current DABUND product information identifies the material as thermoplastic PVC/PA.

What is the structure of the conduit?

The conduit has a smooth inner surface, a corrugated outer surface and a reinforcing member embedded within the conduit wall.

Why does the conduit have a smooth inner surface?

The smooth internal surface helps electrical cable or conductors pass through the conduit during installation.

Is the conduit crush resistant?

The current product information states that a reinforcing member is embedded in the conduit wall to provide self-support and crush resistance.

Is the conduit UV resistant?

The current product information describes the material as resistant to UV exposure, aging and oil.

Is the material RoHS compliant?

The current product information states that the material complies with RoHS requirements. Buyers requiring specific compliance documentation should confirm the applicable report for the exact ordered product.

Does the conduit need a liquid-tight fitting?

Yes. The current product information recommends connecting the conduit with compatible liquid-tight fittings to complete the wiring connection and improve protection against water entry.

What are the liquid-tight connectors made from?

The current product information describes the compatible connectors as nylon.

What substances are the nylon connectors resistant to?

The current product information lists resistance to salt water, weak acids, alcohol, oil, grease and common solvents.

Can this conduit be used for air conditioners and mini splits?

It can be considered for compatible air-conditioning and mini split electrical connections where the conduit size, wiring configuration, fittings and applicable electrical requirements are suitable.

Is this conduit only for 9,000–12,000 BTU mini splits?

No. The current product information mentions 9,000–12,000 BTU mini split installations as one application example, but electrical conduit should be selected according to wiring requirements, conductor size, conduit size, fittings and applicable electrical requirements rather than BTU capacity alone.

Can the conduit be used outdoors?

The current product information lists outdoor applications and describes the material as UV and aging resistant. Buyers should still confirm the required product documentation and environmental rating for the specific project.

Can it be used for pool and spa equipment?

Pool and spa equipment are listed among the product applications. Actual use must comply with the electrical requirements applicable to the installation location and equipment.

Is this conduit LFNC-B or UL 1660 listed?

The current product information does not provide a specific LFNC-B or UL 1660 listing for this SKU. Buyers requiring these classifications should confirm the applicable certification or test documentation before ordering.

How do I select the correct conduit size?

Select the conduit according to conductor quantity and dimensions, cable requirements, fitting size, enclosure connection and the applicable electrical installation requirements.

Can DABUND supply matching liquid-tight connectors?

DABUND supplies liquid-tight fittings and connectors for compatible conduit applications. Confirm the required conduit size, connector type and enclosure connection before ordering.

Can this product be supplied for distributor or project orders?

Product configuration, quantity, packaging and related fitting requirements can be discussed for distributor, wholesaler, contractor and project purchasing.

Related Products

⚫ UL Certificates: E255965; ⚫ Standard: UL 1429; CSA C22.2 NO. 29-15; ⚫ RoHS Compliance.
Condensate Pump Advantages 1.Low noise and non vibration  2.intelligent control  3.automatic start and stop  4.Compact construction, easy assemble

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.