Home Cuprum Pipe Tubus insulatus Cuprum 50 ft 1/4' x 3/8' Tubus cupreus insulatus pro Mini Split & HVAC Systems
50 ft 1/4' x 3/8' Tubus cupreus insulatus pro Mini Split & HVAC Systems
50 ft 1/4' x 3/8' Tubus cupreus insulatus pro Mini Split & HVAC Systems
50 ft 1/4' x 3/8' Tubus cupreus insulatus pro Mini Split & HVAC Systems
50 ft 1/4' x 3/8' Tubus cupreus insulatus pro Mini Split & HVAC Systems
50 ft 1/4' x 3/8' Tubus cupreus insulatus pro Mini Split & HVAC Systems
50 ft 1/4' x 3/8' Tubus cupreus insulatus pro Mini Split & HVAC Systems
50 ft 1/4' x 3/8' Tubus cupreus insulatus pro Mini Split & HVAC Systems
50 ft 1/4' x 3/8' Tubus cupreus insulatus pro Mini Split & HVAC Systems
50 ft 1/4' x 3/8' Tubus cupreus insulatus pro Mini Split & HVAC Systems
50 ft 1/4' x 3/8' Tubus cupreus insulatus pro Mini Split & HVAC Systems
50 ft 1/4' x 3/8' Tubus cupreus insulatus pro Mini Split & HVAC Systems
50 ft 1/4' x 3/8' Tubus cupreus insulatus pro Mini Split & HVAC Systems
1. 1/4' x 3/8' est dimensio in inch. 6.35mm - 9.52mm est e dimensione metrica.
2. 99.9% Fistula aenea pura occurrit ASTM B280 et vexillum C12200. 
3. AC COPERAE Magnitudo quae facere possumus sequenti 1/4' 3/8' 1/2' 5/8' 3/4' 7/8' 1 1/8', longitudo facere potest 15m 20m 25m 30m 50m. 
4. Insulatio facta e 1/2' Polypropylene & UV Resistente occurrit ASTM E 84, UL94, ASTM D1056 et ASTM G 21. Temperatura laborantis ab -40℃ ad 120℃. 
5. Opera ad omnem Aeris condicionem & Refrigeration Applicationem incluso Ductless mini-scidiae, caloris sentinae et Aeris Ductae Unitates centralised. 
6. Pressura Rating: 2100 ad 7000 PSI, multo plus quam 700 PSI pro R410. 
7. Insulationem per nosmetipsos proferimus, societatis nomen, amplitudo, metra etc.
  • DBJ-003

  • DABUND

  • Copper

  • 1M - 50M

Materia

99.9% aeris pura

Color

Nigrum / White

Keywords

Tubus insulatus Cuprum

Applicationem

HVAC
inquire
Add to Basket

Hoc 50 ft 1/4' x 3/8' tubus aeneus insulatus designatus est ad mini- tatem aeris conditionarii, soleatus caloris, et systemata HVAC. Ex alto puritate aeris facta cum officinas velit applicata, refrigerantem translationem efficientem, amissionem energiae imminutam, ac diuturnam operationem efficit.


Tubus aeneus insulatus iam geminus est. Nunc ergo eme.


Product Overview – 50 ft Pre-insulated HVAC Copper Line Set

Haec HVAC aes Tubingae copia 1/4' lineam liquidam et 3/8' lineam suctionis includit , prae insulatas ad facilem institutionem ac certas effectus.

  • Longitudo: 50 ft (15.24 m).

  • Materia: 99.9% aeris pura

  • Insulatio: UV repugnant PE / polypropylene spumae

  • Applicatio: Mini split AC, calor sentinam, ductile HVAC

Una est e communissimis conformationibus figurarum HVAC institutionum residentialium.

Key Features of 1/4' x 3/8' Tubus cupreus insulatas

99.9% purus Cuprum ad High Scelerisque Efficiency

fabricatum cum ASTM B280 & C12200 Aes obsecundantem , praestans conductivity superior thermarum, resistentia corrosionis, et vitae diuturnae servitutis.

High Pressure Rating for Modern Refrigerants

Cum pressione rating 2100-7000 PSI , hoc aeris Tubing cum refrigerantibus compatitur sicut R410A et R32, salvam et efficacem operationem procurans.

De Factory, De Energy PECULIUM Insulation

Pre-insulated Tubing minimizes calor commutationem, refrigerans efficientiam meliorem, et industriam consummationem minuit.

UV Repugnans & Flamma-Retardant Insulation

Insulatio multa signa internationalia in ASTM E84 et UL94 occurrit, praesidium contra ignem, UV detectionem et damnum environmental praebens.

Technical Specifications

Dimensiones aeris Tube

  • Linea liquida: 1/4 inch (6.35 mm)

  • SUCTUS Linea: 3/8 inch (9.52 mm)

Insulation & Temperature Range

  • Insulation Material: Polypropylene / PE Foam

  • Temperature: -40°C ad 120°C

Signa obsequium

  • ASTM B280 (Aeris tubing)

  • ASTM E84 (Ignis resistentia)

  • UL94 (Flamma retardat)

  • ASTM D1056/G21

Haec signa tuta, firmitatem et convenientiam HVAC altum.

Applications - Specimen pro Residentialibus HVAC Systems

Haec tubus aeneus insulatus late in usu est;

  • Mini split aeris conditioners

  • Calor sentinam systemata

  • Ductless HVAC officinae

  • Systemata refrigerationem residentialem

Typice convenit pro 0,75-1 ton (9,000-12,000 BTU) systemata caeli condiciones.


OMNES AES

99.9% Purus Copper

Whit PE Insulated pipe

Alba PE Insulated Pipe


ac aeris linea set59

Plastic Cap



Features fistulae velit tubing:


CANDIDA PE impressa insulatas fistulas


Nulla pipe2

Machinarum ad productionem fistulae scelerisque velit

insulatas aliasque fistulas

Nulla tibiarum CELLA

Nulla pipe1

Iacuit Insulated Pipe



Beneficia Pre-insulated Cuprum Tubing

Improved Energy Efficens

Suscipit tortor leo, et consectetur consequat consequat.

Condensatio Praeventionis

Humorem prohibet aedificare, muros et structuras protegens.

Velocius Installation

Prae-insulate consilium laboris tempus et institutionem multiplicitatem minuit.

Long-Term Durabilitas

Corrosio aeris resistentia cum durabili insulatione coniuncta efficit vitam longam servitutis.

OEM & Customization Services

OEM/ODM solutiones flexibiles sustinemus:

  • Consuetudo longitudinum (1m-50m vel magis)

  • Nulla crassitudine & materia optiones

  • Logo excudendi in velit

  • Mole packaging ad distributores


White PE linee aeris



Tubus insulatus Cuprum

Magnitudo

Longitudo

Insulatio Alba PE

Flamma repugnans

1/4+3/8
15m/20m/25m/30m/50m
8mm/9mm/10mm/13mm/19mm/25.4mm
M1/B1
1/4+1/2
15m/20m/25m/30m/50m
8mm/9mm/10mm/13mm/19mm/25.4mm
M1/B1
1/4+5/8
15m/20m/25m/30m/50m
8mm/9mm/10mm/13mm/19mm/25.4mm
M1/B1
3/8+5/8
15m/20m/25m/30m/50m
8mm/9mm/10mm/13mm/19mm/25.4mm
M1/B1
3/8+3/4
15m/20m/25m/30m/50m
8mm/9mm/10mm/13mm/19mm/25.4mm
M1/B1
1/2+3/4
15m/20m/25m/30m/50m
8mm/9mm/10mm/13mm/19mm/25.4mm
M1/B1
3/8+7/8
15m/20m/25m/30m/50m
8mm/9mm/10mm/13mm/19mm/25.4mm
M1/B1


Linea 1/4 + 3/8 AC posita pro 0.75TON - 1.0TON mini scinditur aer Conditioner.

Mini scissurae lineae 1/4 + 1/2 positae pro 1.5TON - 2.0TON mini scindendae aeris conditionis.

Linea aeris 1/4 + 5/8 adhibita pro 2.0TON - 2.5TON systematis aeris conditionalis scissurae.

3/8 + 5/8 Tubus aeneus insulatus applicandus est ad 3.0TON - 4.0TON ductless mini scissurae aeris Conditioner.

3/8 + 3/4 Tubingae aeris insulatae pro 4.5TON - 6.0TON scindendae institutionis aeris conditionarii adhibitae sunt.

3/8 + 7/8 aeris limbis insulatae applicate pro 6.0TON - 8.0TON ductless mini scissurae aeris Conditioner.


Aeris conditionem aeneam lineam ponit 1/4 + 3/8 pro 0.75P et 1P condiciones aeris scissuras.

Ornamentum fistulae aeris 1/4 + 1/2 communiter pro 1.5P et 2P mini aeris conditioners scissum est.

1/4 + 5/8 linea aenea insulata adhibita pro 2P et 2.5a aeraria condicione adhibita.

3/8 + 5/8 Linea aeris mini- scissae applicanda pro 3P et 4P mini- ducts aeris Conditioner fissuras.

3/8 + 3/4 ornamentum aeris fistulae pro 4.5P et 6P scissurae aircon institutionis adhibitae.

3/8 + 7/8 fistulae aeris insulatae applicandae pro 6P - 8p TON ductile aeris conditioner mini scissae.


1/4 + 3/8 Mini scissurae lineae adhibitae pro 9000BTU et 12000 BTU scissurae aeris conditioner.

Tota aeris linea 1/4 + 1/2 posita communiter pro 12000 BTU et 18000 BTU mini scindendi aeris conditioners adhibita est.

Linea aenea insulata 1/4 + 5/8 posita pro 24000 BTU et 30000 BTU pro aeris conditionis ratione adhibita.

3/8 + 5/8 lineae Mini-scissae applicandae pro 36000 BTU et 48000 ductarum aeris conditioner.

Tubus aeneus insulatus 3/8 + 3/4 usus est pro 54000 BTU et 72000 scissurae institutionis aeris conditionarii.

3/8 + 7/8 fistulam aeneam insulatam adhibere pro 72000 BTU - 96000 BTU ductile aeris Conditioner mini scindendi.


Linea aeris aircon posita 1/4 + 3/8 pro 9K et 12K condituris aeris conditioner adhibita est.

Linea aeris qualitas princeps posuit 1/4 + 1/2 communiter pro 12K et 18K mini scindendae aeris conditioners.

Linea aenea insulata 1/4 + 5/8 posita pro 24K et 30K systematis aeris condicionis adhibita est.

3/8 + 5/8 linea Mini-scissorum applicabilis pro 36K et 48K conditioner aeris ductilis.

3/8 + 3/4 Tubus aeneus insulatus usus 54K et 72K pro institutione aeris fissurandae conditionis.

3/8 + 7/8 Pipinum Copper Insulatum Piping applica pro 72K - 96K ductless mini scindendi aeris Conditioner.



Cur Elige 1/4' x  3/8

Nos fabricamus tubi aeris insulati cum 2008 annis, bonam experientiam gignendi et educendi habemus. Cooperati sumus ante annos IX, amet praestare potest. Singulis septimanis saltem 6-8 40HQ diversis regionibus oneramus. Elige Dabund Negotium feres.

Singuli volumina pre-insulata ad perfecte apta omnia mini-scidis ductilis, VRF, calor soleatus et systemata unitaria institutione.


Qualitas products cum competitive pretium

Pax animi cum officiis professionalibus




DABUND OFFICINA


Insulae Copper Pipe, Mini Split Lineae Set et Aluminium Pipe et Partes HVAC


Factory Profile



SGS Quisque


Mini Split linea facta ex Polypropylene vel Black Purgamentum cum UV Repugnans occurrit ASTM E 84, UL94, ASTM D1056 et ASTM G 21


证书



Exhibition


Exhibitiones toto verbo coniungimus, modo faciliores clientes ad experiendum mini nostrum lineam condensam facie ad faciem.


COMMERCIUM SHOW PARTICIPATIO


FAQ

1. Quid est tubus aeris insulatus pro 50 ft 1/4 x 3/8?

Ponitur ut linea refrigerantia in mini scissurae aeris conditionarii et systematis HVAC, in tectis et velit unitates connectens.


2.Qualis amplitudo AC systematis 1/4' x 3/8' utitur in linea aeris?

Magnitudo haec communiter pro 0,75-1 ton (9,000-12,000 BTU) aeris conditionis systemata scinditur.


3. Cur velit magna ad aeris Tubing?

Insulatio caloris damnum minuit, efficientiam meliorem facit, densationem impedit, praesertim in ambitibus humidis vel velit.


4. Estne hoc cuprum Tubing cum refrigerante R410A compatibile?

Ita refrigerantia moderna sustinet sicut R410A et R32 propter altitudinem pressionis suae rating et obsequii cum HVAC signis.


5. Potestne haec insulata aeris fistula foris adhiberi?

Etiam, velit UV repugnans et weatherproof, est idoneus ad institutionem velit faciendam.


6. Quibus signis hoc aes Tubing occurrit?

Prosequitur ASTM B280, UL94, ASTM E84, ASTM D1056, salutem ac diuturnitatem procurans.


7. Quae sunt commoda tibiarum aeris insularum?

Institutionem temporis minuunt, industriam efficientiam emendant, et qualitatem insulationis convenientem praebent.


8. Possumne insulatas aeris fistulam customize?

Ita, OEM customization praesto est, inter longitudinem, velit crassitudinem, notam, et packaging.


9. Estne 50 ft apta longitudo ad HVAC institutionem?

Ita, 50 ft longitudo mensurae apta est maxime residentialibus installationibus mediocri distantia inter umbraticas et velit unitates.





Related Products

Quaeso eligere data fonte

Ubi est AC Pipe, ibi est Pipe Dabund.

Nos adiuvamus ut foveas vites ad liberandum qualitatem et valorem HVAC&R tuam productis necessariis, in tempore et in-provisione.
Contact us