DABUND R134A AC Refrigerant Gauge is an analog manifold gauge set for servicing compatible R134A air-conditioning and refrigeration systems. It allows technicians to monitor both low-side and high-side refrigerant pressure during system inspection, troubleshooting, evacuation and refrigerant charging procedures.

The manifold uses double O-ring piston valves according to the current product information. Manifold configurations equipped with a sight glass also allow visual observation of liquid during applicable service procedures.

Quick Answer: This product is an analog R134A refrigerant manifold gauge set designed to monitor low-side and high-side pressure during compatible air-conditioning and refrigeration service work.

Ordering Notice: The current product information does not specify the exact low-side pressure range, high-side pressure range, manifold connection size, hose length or hose pressure rating. Confirm these specifications for the exact model before ordering.

R134A Refrigerant Gauge Set Features

Product TypeAC Refrigerant Manifold Gauge Set
RefrigerantR134A
Gauge TypeAnalog
Pressure MonitoringLow-side and high-side refrigerant pressure
Valve DesignDouble O-ring piston valves
Sight GlassAvailable on manifold configurations equipped with a sight glass
Service HoseFilling hose shown in current product information
Typical ApplicationsCompatible R134A air-conditioning and refrigeration service

R134A Manifold Gauge for AC and Refrigeration Service

The manifold gauge set is designed to monitor refrigerant pressure when servicing compatible R134A air-conditioning and refrigeration systems.

The dual-gauge arrangement allows low-side and high-side pressure to be observed from the manifold during applicable system diagnostic and service procedures.

Pressure readings can be used as part of troubleshooting, evacuation and refrigerant charging work when the manifold configuration is correctly matched to the system being serviced.

R134A AC refrigerant manifold gauge set with dual analog gauges

Testing Manifold Double Meter Valve

Filling hose for R134A AC refrigerant manifold gauge set

Filling Hose

Low-Side and High-Side Pressure Monitoring

The analog gauges allow technicians to monitor refrigerant pressure on both sides of a compatible R134A system.

Low-side and high-side readings can support system inspection and troubleshooting during air-conditioning and refrigeration service work.

The current product information does not provide the exact pressure range of either gauge, so these specifications should be confirmed for the selected model before ordering.

Double O-Ring Piston Valves

The current product information identifies the manifold with double O-ring piston valves.

These valves form part of the manifold flow-control arrangement used during compatible HVACR servicing procedures.

Manifold Sight Glass

Manifold configurations equipped with a sight glass allow visual observation of liquid during applicable servicing procedures.

Because the current product information does not confirm that every version includes a sight glass, buyers should verify this feature for the exact R134A manifold gauge configuration being ordered.

Gauge Zero Calibration

Before using the manifold gauge set, check whether the gauges return to 0 psi when not pressurized.

According to the current product instructions, if a gauge does not read 0 psi, remove the gauge face and adjust the calibration screw until the pointer returns to 0 psi.

Checking the zero position before service work helps ensure that pressure readings start from the correct reference point.

R134A Refrigerant Gauge Applications

This R134A refrigerant gauge set can be considered for compatible air-conditioning and refrigeration service work including:

  • R134A air-conditioning system servicing

  • R134A refrigeration system servicing

  • Low-side refrigerant pressure monitoring

  • High-side refrigerant pressure monitoring

  • System troubleshooting support

  • Evacuation procedures

  • Refrigerant charging procedures

  • Cooling system maintenance and repair

How to Select an R134A Manifold Gauge Set

Confirm R134A Compatibility

Confirm that the selected manifold gauge configuration is intended for the R134A system being serviced.

Confirm the Gauge Pressure Ranges

Verify the low-side and high-side gauge pressure ranges for the exact model before ordering.

Confirm the Manifold Connection Size

Check the manifold port and service hose connection dimensions against the equipment and service accessories that will be used.

Confirm Hose Specifications

Confirm the required hose quantity, hose length, connection size and pressure specification for the intended servicing application.

Confirm Whether a Sight Glass Is Required

If a manifold sight glass is required for the intended service procedure, verify that the selected configuration includes one.

How to Check the Gauge Before Use

Step 1: Inspect the Gauge Set

Inspect the manifold, gauges, valves and filling hoses before connecting the gauge set to the system.

Step 2: Check the Zero Position

Confirm that each analog gauge reads 0 psi when it is not pressurized.

Step 3: Adjust the Gauge if Required

If a gauge does not return to 0 psi, the current product instructions state that the gauge face can be removed and the calibration screw adjusted to return the pointer to zero.

Step 4: Confirm Hose Connections

Confirm that the filling hoses and manifold connections match the intended R134A service setup before use.

Important Safety Notice

Caution: Never open the high-side valve on the manifold gauge set while the air-conditioning system is operating.

Confirm valve positions and hose connections before connecting the manifold gauge set to the system and follow the service procedures applicable to the equipment being serviced.

Information to Confirm Before Ordering

HVAC distributors, refrigeration service companies, wholesalers and professional technicians should confirm the following information before ordering:

  • R134A refrigerant compatibility

  • Low-side gauge pressure range

  • High-side gauge pressure range

  • Gauge scale and measurement units

  • Gauge diameter

  • Manifold connection size

  • Service hose connection size

  • Hose quantity

  • Hose length

  • Hose working pressure

  • Whether a sight glass is required

  • Package contents

  • Order quantity

  • Packaging requirements

  • OEM or private-label requirements

These parameters are not fully specified in the current product information and should be confirmed for the exact model before placing an order.

R134A Gauge Sets for Distributors and HVACR Service Companies

DABUND supplies refrigerant manifold gauge sets and related HVAC installation and service products for distributors, wholesalers, contractors and professional service companies.

OEM and ODM requirements can be discussed according to manifold configuration, gauge requirements, hose configuration, packaging and commercial purchasing requirements.

Frequently Asked Questions

What is an R134A refrigerant gauge set used for?

It is used to monitor low-side and high-side refrigerant pressure during compatible R134A air-conditioning and refrigeration service procedures.

Is this manifold gauge set designed for R134A?

Yes. This product page identifies the gauge set as an R134A refrigerant gauge.

Is this an analog or digital refrigerant gauge?

The current product information and images show an analog manifold gauge configuration.

Does the gauge set measure both low-side and high-side pressure?

Yes. The manifold is designed to monitor both low-side and high-side refrigerant pressure during applicable service procedures.

Does the manifold use double O-ring piston valves?

Yes. The current product information identifies the manifold with double O-ring piston valves.

Does the R134A manifold gauge set include a sight glass?

Some manifold configurations may include a sight glass. Confirm whether the exact R134A model being ordered includes this feature.

Can this gauge set be used for refrigerant charging?

Yes. The current product information identifies refrigerant charging as one of the manifold gauge set applications when the product is correctly configured for the system being serviced.

Can the manifold gauge set be used during evacuation?

The current product information identifies evacuation as an applicable service procedure for manifold gauge sets.

What should I do if the gauge does not read 0 psi?

According to the current product instructions, remove the gauge face and adjust the calibration screw until the pointer returns to 0 psi.

What is the pressure range of the R134A gauges?

The current product information does not specify the low-side or high-side gauge pressure ranges. Confirm these specifications for the exact model before ordering.

What connection size does this R134A gauge set use?

The current product information does not specify the manifold port or hose connection size. Confirm the required connection dimensions before ordering.

Are filling hoses included?

Filling hoses are shown in the current product information. Confirm the exact quantity, hose length, connection size and package contents for the selected model.

Can I open the high-side valve while the AC system is operating?

No. The current product instructions specifically state that the high-side manifold valve should not be opened while the air-conditioning system is operating.

Can DABUND provide OEM or ODM R134A manifold gauge sets?

Yes. OEM and ODM requirements can be discussed according to manifold configuration, gauge requirements, hose configuration, packaging and commercial order requirements.

Can I request a sample?

Sample requests are available according to the current sales policy.    View sample information.

What payment terms are available?

Available payment methods can include T/T, L/C at sight and credit card. Final payment terms depend on the commercial agreement.

What delivery terms are available?

Available international trade terms can include EXW, FOB, CFR and CIF.

What is the typical delivery time?

The current product information lists a typical delivery period of approximately 15–20 days. Actual lead time depends on order quantity, product configuration, customization and production schedule.

Related Products

Product name: Anti-vibration rubber pads Composition:natural rubber + carbon clack +anti-aging system. Scope:Home air conditiong Product Features:Hot galvanize screw, rubber material, durable Design, strong rubber Product Advantages: Anti-corrosion, shock absorber noise reduction, easy to install
1.Mini Split Installation Kit including one set air conditioner insulated copper pipe, size 3/8"+3/4" 25 ft, and other accessories, like communication wire cable, drain hose 3m, wall pipe and cover and the other necessary parts.  2. Both of the two copper pipe end do flaring and nuts.  3. The insulation we can offer White PE and Black Rubber. White PE thickness is 3/8" 1/2" 3/4" 1" or 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Rubber thickness is 1/2" 3/4" 1" or 13mm 17mm 19mm 25.4mm.  4. For the AC Installation kit, most popular size is 3m 4m and 5m. Europe want 6m 7m 8m 10m.  5. For the insulation we have SGS test report including ASTM E 84, UL 94, ASTM D1056, ASTM G 21, and copper pipe meets ASTM B280 AND C12200.  6.Professional manufacturer of Mini Split Installation Kit, 2 factories, 1,000,000PCS per month, 5days for sample and 14years' experience.
Hot rolled plate construction,Strong and Durable. Anti-rusting,anti-corrosion and weather resistant,Perfect for long-term outdoor use. Fits most of mini split ductless air conditioner heat pump systems.  

INNOVATING HVAC LINE SET, POWERING GLOBAL COMFORT.

We help you avoid the pitfalls to deliver the quality and value your HVAC/R products need, on-time and on-budget.