30 ft 1/4' x 3/8' Kit Instalasi Mini Split
30 ft 1/4' x 3/8' Kit Instalasi Mini Split
30 ft 1/4' x 3/8' Kit Instalasi Mini Split
30 ft 1/4' x 3/8' Kit Instalasi Mini Split
30 ft 1/4' x 3/8' Kit Instalasi Mini Split
30 ft 1/4' x 3/8' Kit Instalasi Mini Split
30 ft 1/4' x 3/8' Kit Instalasi Mini Split
30 ft 1/4' x 3/8' Kit Instalasi Mini Split
30 ft 1/4' x 3/8' Kit Instalasi Mini Split
30 ft 1/4' x 3/8' Kit Instalasi Mini Split
30 ft 1/4' x 3/8' Kit Instalasi Mini Split
30 ft 1/4' x 3/8' Kit Instalasi Mini Split
1.Mini Split Instalasi Kit kalebu siji pesawat air conditioner terisolasi pipe tembaga, ukuran 1/4 '+3/8' 30 ft, lan aksesoris liyane, kaya kabel kabel komunikasi, saluran selang 3m, wall pipe lan tutup lan bagean perlu liyane. 
2. Loro-lorone saka loro tembaga pipe pungkasan apa flaring lan perkakas. 
3. Ing jampel kita bisa kurban Putih PE lan Black Karet. Ketebalan PE putih yaiku 3/8 ' 1/2 ' 3/4 ' 1 ' utawa 8mm 9mm 10mm 13mm 19mm 25.4mm. Black Karet kekandelan punika 1/2 ' 3/4 ' 1 ' utawa 13mm 17mm 19mm 25.4mm. 
4. Kanggo kit Instalasi AC, ukuran sing paling populer yaiku 3m 4m lan 5m. Eropa pengin 6m 7m 8m 10m. 
5. Kanggo jampel kita duwe laporan test SGS kalebu ASTM E 84, UL 94, ASTM D1056, ASTM G 21, lan pipe tembaga meets ASTM B280 lan C12200. 
6. Produsen profesional Kit Instalasi Split Mini, 2 pabrik, 1,000,000PCS saben wulan, 5 dina kanggo sampel lan pengalaman 14 taun.
  • DBJ-003

  • DABUND

  • Tembaga

  • 1M - 10M

Bahan

99,9% tembaga murni

warna

Ireng/Putih

Tembung kunci

Kit Instalasi Split Mini

Aplikasi

HVAC
Inquire
Tambah menyang Basket

30 Ft 1/4' x 3/8' Kit Instalasi Split Mini

DABUND 30 ft 1/4 ' x 3/8 ' Kit Instalasi Split Mini nggabungake tabung refrigeran tembaga sing wis terisolasi karo aksesori instalasi sing umum dibutuhake kanggo kondhisi hawa pamisah mini tanpa saluran sing kompatibel lan sistem pompa panas.

Kit kasebut kalebu 30 ft / kira-kira 9,14 m pasangan 1/4 ' lan 3/8 ' pipa tembaga, kabel kabel komunikasi, selang saluran 3 m, pipa tembok lan tutup tembok. Loro-lorone ujung pipa tembaga diobong lan diwenehake kacang.

Dhiameter njaba tabung tembaga kira-kira 6,35 mm lan 9,52 mm. Ing peralatan HVAC sing kompatibel, 1/4 'tabung umume minangka saluran refrigeran cair nalika tabung 3/8' fungsi minangka saluran nyedhot utawa bali gas.

Konfigurasi sing ditampilake nggunakake insulasi PE Putih. Insulasi karet ireng lan macem-macem pilihan kekandelan insulasi uga kasedhiya miturut konfigurasi kit instalasi sing diprentahake.

Jawaban Cepet: Iki 30 ft / kira-kira 9,14 m kit instalasi pamisah mini karo 1/4 'lan 3/8 ' tabung tembaga wis terisolasi, flared ends karo perkakas, kabel komunikasi, selang saluran, pipo tembok lan tutup tembok kanggo instalasi HVAC kompatibel.

Kabar Kompatibilitas: Konfirmasi ukuran pipa refrigeran sing dibutuhake, dawa pipa sing diidini, jinis sambungan, syarat kabel komunikasi lan susunan saluran kondensat kanggo model peralatan njero ruangan lan ruangan sing pas sadurunge dipasang.

Apa sing Klebu ing Kit Instalasi Split Mini 30 Ft?

Tubing Tembaga Insulated1/4' + 3/8', 30 ft / kira-kira. 9,14 m
Tembaga Tube EndsFlared ends karo kacang
Kabel Komunikasi KabKlebu miturut konfigurasi kit
Selang pembuangan3 m
Pipa TembokKlebu
Tutup TembokKlebu
Aksesoris TambahanMiturut konfigurasi instalasi-kit dhawuh

30 Ft 1/4' x 3/8' Spesifikasi Kit Split Mini

MerkDABUND
Jinis produkKit Instalasi Split Mini
Ukuran Pipa Tembaga1/4' + 3/8'
Metrik Diameter njabaKira-kira. 6,35 mm + 9,52 mm
Fungsi Line Umum1/4 'garis cair + 3/8' garis nyedhot / gas ing peralatan sing kompatibel
dawa30 ft / kira-kira. 9,14 m
Bahan TembagaTembaga kemurnian dhuwur / C12200 DHP miturut spesifikasi
Pipa Tembaga StandarSpesifikasi ASTM B280 kasedhiya
Isolasi sing ditampilakeIsolasi PE putih
Pilihan Kekandelan PE Putih8 mm / 9 mm / 10 mm / 13 mm / 19 mm / 25,4 mm miturut konfigurasi
Pilihan Karet Ireng13 mm / 17 mm / 19 mm / 25,4 mm miturut konfigurasi
Selang pembuangan3 m
AplikasiKompatibel ductless mini pamisah AC lan instalasi pump panas
OEM / ODMKasedhiya miturut konfigurasi kit dhawuh

Fitur Utama Kit Instalasi Split Mini 30 Ft

Pra-Insulated 1/4' x 3/8' Tembaga Line Set

Kit instalasi kalebu pipa tembaga refrigeran 1/4 'lan 3/8' sing dipasangake. Ing peralatan sing kompatibel, 1/4 'tabung umume minangka garis cair nalika tabung 3/8' umume minangka saluran nyedhot utawa bali gas.

30 Ft / 9,14 m Dawane Instalasi

Garis tembaga 30 ft nyedhiyakake pipa refrigeran kira-kira 9,14 m, nggawe konfigurasi iki migunani kanggo instalasi sing kompatibel ing ngendi kit 20 ft utawa 25 ft ora nyedhiyakake jarak rute sing cukup.

Pre-Flared Ends Kanthi Kacang Tembaga

Loro-lorone ujung pipa tembaga diwenehake karo sambungan flared lan kacang, ngurangi preparation lapangan ngendi dimensi suar lan desain sambungan cocog karo peralatan HVAC.

Kabel Kabel Komunikasi Klebu

Kabel kabel komunikasi kalebu miturut konfigurasi kit sing dipilih. Konfirmasi count konduktor, ukuran kabel lan syarat sambungan marang diagram kabel peralatan sadurunge instalasi.

Saluran Saluran, Pipa Tembok lan Tutup Tembok

Selang saluran 3 m, pipa tembok lan tutup tembok kalebu kanggo ndhukung saluran kondensat lan rute pipa lan kabel liwat tembok bangunan miturut konfigurasi kit sing dipilih.

Isolasi PE Putih

Konfigurasi sing ditampilake nggunakake insulasi PE Putih ing sekitar pipa tembaga. Insulasi mbantu nyuda transfer panas sing ora dikarepake, penetrasi kelembapan lan kontak fisik karo pipa tembaga sajrone instalasi.

Pipa tembaga kemurnian dhuwur kanggo kit instalasi pamisah mini 30 ft 1/4 x 3/8

Tembaga Kemurnian Dhuwur

Pipa tembaga terisolasi PE putih kanggo kit instalasi pamisah mini

Pipa Insulated PE Putih

Kacang suar tembaga kanggo kit instalasi pamisah mini

Flared Ends Kanthi Kacang

Struktur Isolasi PE Putih

Sistem insulasi PE Putih sing ditampilake nggunakake konstruksi multi-lapisan sing dirancang kanggo nyedhiyakake insulasi termal lan proteksi permukaan ing sekitar pipa refrigeran tembaga.

Isolasi embossed PE putih kanggo pipa tembaga pamisah mini

DABUND peralatan produksi pipa isolasi

Produksi Pipa Isolasi

DABUND gudang pipa terisolasi

Gudang Pipa Insulated

Lapisan insulasi njero kanggo pipa tembaga sing wis diisolasi

Lapisan Insulasi Inner

Lapisan njaba PE Embossed

Lapisan njaba nggunakake film PE embossed sing dirancang kanggo nyedhiyakake proteksi lumahing, nyandhang resistance lan resistance kanggo kahanan tuwa ruangan.

Kandhel-Sel Busa Lapisan Tengah

Lapisan insulasi tengah nggunakake busa sel padhet sing dirancang kanggo insulasi termal, panyerepan impact lan resistensi penetrasi banyu.

Lapisan Inner Sel Tertutup

Lapisan insulasi njero nggunakake struktur sel tertutup kanggo ndhukung insulasi termal lan sesak udara ing sekitar pipa tembaga. Konfigurasi sing dipilih didaftar kanthi kisaran suhu kira-kira -40°C nganti 120°C.

Kasedhiya Insulation Testing

Informasi produk saiki referensi tes insulasi sing ana gandhengane karo ASTM E84, UL 94, ASTM D1056, ASTM G21, ASTM C1427 lan UL 723 miturut bahan lan spesifikasi insulasi sing dipilih. Para panuku kudu ngonfirmasi dokumentasi sing ditrapake kanggo konfigurasi sing dipesen kanthi tepat.

Napa Pilih Kit Instalasi Mini Split Lengkap 30 Ft?

Kit instalasi pamisah mini lengkap nggabungake tabung tembaga refrigeran kanthi aksesoris sing umum dibutuhake, mbantu distributor lan installer HVAC nyedhiyakake sawetara komponen instalasi ing siji paket.

Dibandhingake karo mung tuku set baris tembaga terisolasi, kit iki uga kalebu kabel komunikasi, selang saluran, pipa tembok lan tutup tembok miturut konfigurasi sing dipilih.

Konfigurasi 30 ft / kira-kira 9,14 m nyedhiyakake fleksibilitas rute sing luwih gedhe tinimbang kit 20 ft utawa 25 ft kanggo instalasi sing kompatibel ing ngendi peralatan njero ruangan lan ruangan dipanggonke luwih adoh.

Kit instalasi pamisah mini PE putih 30 ft 1/4 x 3/8

30 Ft Pertimbangan Instalasi Split Mini

Verifikasi Ukuran Pipa 1/4' x 3/8' sing dibutuhake

Konfirmasi manawa peralatan HVAC njero ruangan lan ruangan mbutuhake kira-kira 6,35 mm lan 9,52 mm tabung refrigeran diameter njaba. Sistem kapasitas sing padha bisa mbutuhake dimensi pipa sing beda.

Konfirmasi Panjang Pipa 30 Ft

Priksa manawa kira-kira 30 ft / 9,14 m cocok kanggo rute pipa refrigeran sing direncanakake lan ana ing watesan pipa minimal lan maksimum sing ditemtokake dening pabrikan peralatan HVAC.

Priksa Sambungan Pre-Flared

Pipa tembaga disedhiyakake karo ujung lan kacang. Installers kudu konfirmasi dimensi suar, ukuran sambungan lan kondisi suar sadurunge perakitan final.

Verifikasi Syarat Kabel Komunikasi

Keperluan listrik lan komunikasi beda-beda ing antarane sistem pamisah mini. Konfirmasi count konduktor, ukuran kabel lan syarat sambungan marang diagram kabel peralatan.

Rencanakan Rute Saluran Kondensat

Kit kalebu selang saluran 3 m. Konfirmasi manawa dawa selang saluran sing diwenehake cocog kanggo instalasi utawa nemtokake manawa komponen saluran banyu tambahan dibutuhake.

Priksa Syarat Ngisi Refrigerant

Sawetara sistem HVAC kalebu biaya refrigeran pabrik kanggo dawa pipa standar sing ditemtokake. Tindakake pandhuan pabrikan peralatan kanggo nemtokake manawa pangaturan refrigeran dibutuhake kanggo instalasi 30 ft.

Ngindhari Tubing Tembaga Keluwihan sing Ora Perlu

Pilih dawa kit sing nyedhiyakake jarak rute sing cukup tanpa nggawe pipa refrigeran sing ora perlu. Tindakake syarat pabrikan peralatan nalika ngarahake dawa pipa tambahan.

Apa 1/4' x 3/8' Kompatibel karo Split Mini?

Kombinasi pipa refrigeran 1/4 'x 3/8' digunakake dening kondhisi hawa pamisah mini tanpa saluran sing dipilih lan sistem pompa panas.

Sawetara sistem ing kira-kira 9.000–12.000 kelas BTU bisa nggunakake dimensi kasebut, nanging iki dudu aturan ukuran universal.

Peralatan kanthi kapasitas nominal sing padha bisa mbutuhake dimensi garis cairan lan garis nyedhot sing beda. Tansah verifikasi spesifikasi pipa kanggo model peralatan sing pas.

Kasedhiya Ukuran Kit Instalasi Split Mini

UkuranPilihan dawaIsolasi PE PutihPilihan Flame-Tahan
1/4 + 3/8SKU saiki: 30 ft / approx. 9,14 m; opsi kit luwih jembar kalebu 3m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
1/4 + 1/23m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
1/4 + 5/83m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
3/8 + 5/83m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
3/8 + 3/43m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
1/2 + 3/43m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1
3/8 + 7/83m / 4m / 5m / 7m / 10m8mm / 9mm / 10mm / 13mm / 19mm / 25.4mmM1 / B1

Kit Instalasi Split Mini kanggo Distributor HVAC

DABUND nyedhiyakake kit instalasi pamisah mini menyang distributor HVAC, grosir, importir, kontraktor, pemasok proyek lan merek label pribadi.

Konfigurasi PE Putih 30 ft 1/4' x 3/8' Putih nggabungake tabung tembaga refrigeran lan aksesoris instalasi sing umum dibutuhake kanggo instalasi sing kompatibel sing mbutuhake jarak rute udakara 9,14 m.

OEM lan Custom Mini Split Instalasi Kits

DABUND ndhukung pasokan OEM lan ODM miturut konfigurasi kit instalasi pamisah mini sing dibutuhake.

  • Kombinasi tabung tembaga khusus

  • Dawane garis khusus

  • PE putih utawa opsi insulasi karet ireng

  • Multiple ketebalan insulasi

  • Konfigurasi kabel komunikasi

  • Selang saluran lan konfigurasi aksesoris tembok

  • Identifikasi produk sing dicithak

  • Kemasan label pribadi

Napa Pilih DABUND Mini Split Instalasi Kit?

Pengalaman Manufaktur HVAC Wiwit 2008

DABUND wis nggawe komponen HVAC wiwit 2008, nyedhiyakake kit instalasi pamisah mini, pipa tembaga terisolasi, set baris lan produk HVAC sing gegandhengan karo pelanggan internasional.

Konfigurasi Kit Lengkap

Pipa tembaga, kabel komunikasi, selang saluran, pipa tembok lan tutup tembok bisa diwenehake minangka konfigurasi kit instalasi kanggo distributor lan installer HVAC.

Multiple Ukuran lan Dawane

Multiple kombinasi tabung tembaga, dawa kit lan opsi jampel ngidini panuku kanggo milih konfigurasi miturut peralatan lan syarat pasar.

Pabrik DABUND

DABUND ngasilake pipa tembaga terisolasi, set garis pamisah mini, kit instalasi lan komponen HVAC sing gegandhengan kanggo pelanggan B2B internasional.

Pabrik DABUND kanggo kit instalasi pamisah mini lan pipa tembaga terisolasi

SGS Testing lan Insulation Standards

Informasi produk saiki referensi tes insulasi sing ana gandhengane karo ASTM E84, UL 94, ASTM D1056 lan ASTM G21, dene pipa tembaga kasedhiya kanggo spesifikasi ASTM B280 lan C12200. Para panuku kudu ngonfirmasi dokumentasi sing ditrapake kanggo konfigurasi sing dipesen kanthi tepat.

Dokumentasi pengujian SGS kanggo insulasi kit instalasi pamisah mini DABUND

Pameran HVAC Internasional

DABUND melu pameran HVAC internasional kanggo nampilake kit instalasi pamisah mini, pipa tembaga terisolasi lan produk HVAC sing gegandhengan karo distributor, importir lan para panuku profesional.

DABUND kit instalasi pamisah mini ing pameran HVAC internasional

Pitakonan sing Sering Ditakoni

Apa sing kalebu ing kit instalasi pamisah mini 30 ft?

Informasi produk saiki dhaptar 30 ft 1/4 'x 3/8' terisolasi baris tembaga line set, kabel kabel komunikasi, 3 m selang saluran, wall pipe lan tutup tembok, bebarengan karo aksesoris tambahan miturut konfigurasi kit milih.

Suwene iku baris tembaga disetel?

Set garis refrigeran tembaga dawane 30 ft, padha karo kira-kira 9,14 m.

Apa ukuran metrik pipa tembaga 1/4 'lan 3/8'?

Tabung tembaga 1/4' duwe diameter njaba kira-kira 6,35 mm, dene tabung tembaga 3/8' duwe diameter njaba kira-kira 9,52 mm.

Apa ends pipa tembaga wis flared?

ya wis. Informasi produk saiki nyatakake yen loro ujung pipa tembaga diobong lan diwenehake kacang.

Pipa endi sing biasane dadi garis cair lan sing dadi garis nyedhot?

Ing sistem HVAC sing kompatibel, tabung 1/4' umume fungsi minangka garis cair nalika tabung 3/8' fungsi minangka saluran nyedhot utawa gas. Tansah verifikasi spesifikasi pipa pabrikan peralatan.

Apa kapasitas pamisah mini nggunakake set baris 1/4 'x 3/8'?

Sawetara sistem ing kira-kira 9.000-12.000 kelas BTU bisa nggunakake kombinasi pipa iki, nanging iki ora universal. Peralatan kapasitas sing padha bisa mbutuhake dimensi pipa refrigeran sing beda.

Bisa milih kit instalasi dening kapasitas BTU piyambak?

Ora Konfirmasi dimensi tabung refrigerant, jinis sambungan, dawa pipa allowable, syarat electrical lan konfigurasi saluran condensate kanggo model HVAC pas.

Nalika aku kudu milih kit instalasi pamisah mini 30 ft?

Kit 30 ft bisa migunani ing ngendi kit instalasi 20 ft utawa 25 ft cendhak banget lan tata letak peralatan mbutuhake pipa refrigerant kira-kira 9,14 m, yen pabrikan HVAC ngidini dawa iki.

Apa set baris 30 ft cocok kanggo saben pamisah mini?

No. Verifikasi yen kira-kira 30 ft / 9,14 m ana ing watesan minimal lan maksimum refrigerant pipa sing ditemtokake dening pabrikan peralatan.

Apa set baris 30 ft mbutuhake refrigeran tambahan?

Iku gumantung ing peralatan. Sawetara sistem kalebu biaya refrigeran pabrik mung dawa pipa standar sing ditemtokake. Tindakake instruksi pangisian daya saka pabrikan kanggo model sing tepat.

Apa insulasi sing digunakake ing kit instalasi iki?

Konfigurasi produk sing ditampilake nggunakake insulasi PE Putih. Insulasi karet ireng uga kasedhiya miturut spesifikasi kit sing dipesen.

Apa ketebalan insulasi PE Putih sing kasedhiya?

Informasi produk saiki dhaptar pilihan kekandelan insulasi PE Putih kalebu 8 mm, 9 mm, 10 mm, 13 mm, 19 mm lan 25,4 mm miturut konfigurasi.

Apa isolasi karet ireng uga kasedhiya?

ya wis. Opsi insulasi karet ireng uga kasedhiya miturut konfigurasi instalasi-kit sing dipilih.

Suwene selang saluran sing kalebu?

Informasi produk saiki nampilake selang pembuangan 3 m.

Apa DABUND bisa ngatur kit instalasi pamisah mini?

ya wis. Konfigurasi OEM lan ODM bisa kalebu ukuran tabung tembaga sing beda-beda, dawa kit, opsi insulasi, identifikasi dicithak lan aksesoris instalasi miturut syarat panuku.

Apa aku bisa njaluk conto sadurunge nggawe pesenan akeh?

ya wis. Miturut informasi produk saiki, DABUND bisa nyedhiyakake telung potongan sampel kanggo evaluasi, kanthi panuku nutupi biaya pengiriman ekspres. Deleng informasi conto.

Apa syarat pembayaran sing kasedhiya?

Cara pembayaran sing kasedhiya bisa kalebu T / T, L / C ing ngarsane lan kertu kredit. Syarat pembayaran pungkasan gumantung ing persetujuan komersial.

Apa syarat pangiriman sing kasedhiya?

Istilah perdagangan internasional bisa kalebu EXW, FOB, CFR lan CIF miturut syarat logistik panuku.

Apa wektu pangiriman sing khas?

Informasi produk saiki nyathet pangiriman khas kira-kira 15-20 dina. Wektu timbal nyata gumantung saka jumlah pesenan, spesifikasi produk, kustomisasi lan jadwal produksi.

Sapa sing kudu nginstal kit instalasi pamisah mini?

Sambungan pipa refrigeran, kabel listrik, tes tekanan, evakuasi, ngisi refrigeran lan saluran kondensat kudu rampung dening personel HVAC sing mumpuni miturut syarat lokal lan instruksi pabrikan peralatan.

Produk sing gegandhengan

1.1/2' x 3/4' iku ukuran metu ing inch. 12.7mm - 19.05mm minangka ukuran metu ing metrik. 2. 99,9% pipa tembaga murni ketemu standar ASTM B280 lan C12200. 3. AC Tembaga Ukuran apa sing bisa kita tindakake ing ngisor iki 1/4 ' 3/8 ' 1/2 ' 5/8 ' 3/4 ' 7/8 ' 1 1/8 ', dawa bisa nindakake 15m 20m 25m 30m 50m. 4. Isolasi digawe saka 1/2 & 'Resistansi 1/2 & ' Polypropylene UV. UL94, ASTM D1056 lan ASTM G 21. Suhu kerja saka -40 ℃ nganti 120 ℃. 5. Dianggo kanggo saben Air Conditioning & Pendingin Aplikasi kalebu Ductless mini-split, pump panas lan Centralized Air Ducted Unit. 6. Rating meksa: 2100 kanggo 7000 PSI, luwih saka dibutuhake 700 PSI kanggo R410. 7. Insulation kita gawé dhewe, bisa print jeneng perusahaan, ukuran, meter etc.
1. 3/8 ' x 3/4 ' punika ukuran metu ing inch. 9.52mm - 19.05mm minangka ukuran metu ing metrik. 2. 99,9% pipa tembaga murni ketemu standar ASTM B280 lan C12200. 3. AC Tembaga Ukuran apa sing bisa kita tindakake ing ngisor iki 1/4 ' 3/8 ' 1/2 ' 5/8 ' 3/4 ' 7/8 ' 1 1/8 ', dawa bisa nindakake 15m 20m 25m 30m 50m. 4. Isolasi digawe saka 1/2 & 'Resistansi 1/2 & ' Polypropylene UV. UL94, ASTM D1056 lan ASTM G 21. Suhu kerja saka -40 ℃ nganti 120 ℃. 5. Dianggo kanggo saben Air Conditioning & Pendingin Aplikasi kalebu Ductless mini-split, pump panas lan Unit Air Ducted terpusat. 6. Rating meksa: 2100 kanggo 7000 PSI, luwih saka dibutuhake 700 PSI kanggo R410. 7. Insulation kita gawé dhewe, bisa print jeneng perusahaan, ukuran, meter etc.
1. 3/8 ' x 3/4 ' punika ukuran metu ing inch. 9.52mm - 19.05mm minangka ukuran metu ing metrik. 2. 99,9% pipa tembaga murni ketemu standar ASTM B280 lan C12200. 3. AC Tembaga Ukuran apa sing bisa kita tindakake ing ngisor iki 1/4 ' 3/8 ' 1/2 ' 5/8 ' 3/4 ' 7/8 ' 1 1/8 ', dawa bisa nindakake 15m 20m 25m 30m 50m. 4. Isolasi digawe saka 1/2 & 'Resistansi 1/2 & ' Polypropylene UV. UL94, ASTM D1056 lan ASTM G 21. Suhu kerja saka -40 ℃ nganti 120 ℃. 5. Dianggo kanggo saben Air Conditioning & Pendingin Aplikasi kalebu Ductless mini-split, pump panas lan Centralized Air Ducted Unit. 6. Rating meksa: 2100 kanggo 7000 PSI, luwih saka dibutuhake 700 PSI kanggo R410. 7. Insulation kita gawé dhewe, bisa print jeneng perusahaan, ukuran, meter etc.
1.1/4' x 1/2' iku ukuran metu ing inch. 6.35mm - 12.7mm minangka ukuran metu ing metrik. 2. 99,9% pipa tembaga murni ketemu standar ASTM B280 lan C12200. 3. Ukuran Tembaga AC apa sing bisa kita tindakake ing ngisor iki 1/4 ' 3/8 ' 1/2 ' 5/8 ' 3/4 ' 7/8 ' 1 1/8 ', dawa bisa nindakake 15m 20m 25m 30m 50m. 4. Insulasi digawe saka 1/2 & ' Resistansi UV 4. UL94, ASTM D1056 lan ASTM G 21. Suhu kerja saka -40 ℃ nganti 120 ℃. 5. Dianggo kanggo saben Air Conditioning & Pendingin Aplikasi kalebu Ductless mini-split, pump panas lan Unit Air Ducted terpusat. 6. Rating meksa: 2100 kanggo 7000 PSI, luwih saka dibutuhake 700 PSI kanggo R410. 7. Insulation kita gawé dhewe, bisa print jeneng perusahaan, ukuran, meter etc.

INNOVATING HVAC LINE SET, POWERING GLOBAL comfort.

Kita mbantu sampeyan supaya pitfalls kanggo ngirim kualitas lan nilai HVAC / R produk perlu, ing wektu lan ing budget.